ML18085A360

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 80-21, Valve Yokes Supplied by Malcolm Foundry Co,Inc. Written Response Required
ML18085A360
Person / Time
Site: Salem  
Issue date: 11/06/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Schneider F
Public Service Enterprise Group
References
NUDOCS 8012120060
Download: ML18085A360 (5)


Text

Docket Nos. 50-272 50-311 UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA 19406 November 6, 1980 Public Service Electric and Gas Company ATTN:.

Mr. F. W. Schneider Vice Prestdent - Production 80 Park Plaza - 15A Newark, New Jersey 07101 Gentlemen:

~

(..Q

-i

u cu CO'-
u::!~

J>o

z:z;::z::

C-J

i
_;;
C~0
u C')

m

(,/>

65 q

r' t

a:

{.,.,.)

(./) r-.1

<::)

r.i~1:~ _

~

~~J

' -r~- I J

.G"~) r.::)

f'fl(A

~~

'.!:o>*

~;

J
'._~

CQ' H~~ -I

~

\\,(j The enclosed IE Bulletin No. 80-21, 11Valve Yokes Supplied by Malcolm Foundry Company, Inc.,

11 is forwarded to you for action.

A written response is required.

In order to assist the NRC in evaluating the value/impact of each Bulletin on licensees, it wou.ld be helpful if you would provide an estimate of the manpower expended in conduct of the review and preparationof the report(s) required by the Bulletin.

Please estimate separately the manpower associated with corrective actions following identification of problems through the Bulletin.

If you desire* additi9nal informfttion regardi.ng this-matter, pl.ease contact this office.

Sincerely, lJ1.~

Grier

Enclosures:

l.

IE Bulletin No. 80-21

2.

List of Recently Issued IE Bulletins CONTACT:

L. E. Tripp (215-337-5282) cc w/encls:

F. P. Librizzi, General Manager - Electric Production E. N. Schwalje, Manager - Quality Assurance R. L. Mittl, General Manager - Licensing and Environment H. J. Midura, Manager - Salem Generating Station R. A. Uderitz, General Manager - Fuel Supply Department Q

UNITED STATES

. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 November 6,. 1980 SSINS No.:

6820 Accession No.:

8008220246 IEB 80-21 Page 1. of 3 IE BULLETIN NO. 80-21:

VALVE YOKES SUPPLIED BY MALCOLM FOUNDRY COMPANY, INC.

Description of Circumstances:

On June 17, 1980, Pennsylvania Power and Light Company notified IE Region I that cracks had been discovered in the yokes of a number of va.lves in the residual heat removal (RHR) system at their Susquehanna Steam Electric Station.

The potential for common-mode failure of the yokes on several valves in redundant, safety-related trains of the RHR system constitutes a failure mode whereby all RHR functions could be simultaneously lost. Specifically, the cracks were loca.ted in the radii at the yoke mounting flange-to-yoke vertical section interface.

An analysis and evaluation of the most severely cracked valve yoke was performed.

by the valve.manufacturer, Anchor Darling Valve Company.

They concluded that the* cracking was not due to casting defects, but rather was due to the yoke material not having the proper mechanical. properties.

Purchased as ASTM A-216, Grade WCB material, the actual valve yoke material had tensile and yield strengths below the minimum values listed in the ASTM material specification.

The* cracked valve yokes were all_ cast by Malcolm Foundry Company, Inc., of Newark, New Jersey~ The foundry is no longer in business.

Anchor Darling has begun a program of verifying the tensile strengths of the other valve yokes cast by Malcolm and used on Anchor Darling valves at Susquehanna.

To date, approximately half of the valve yokes have been tested.

Of those tested, over 25 percent of the valve yokes have revealed Brinell hard-ness values significantly below the appropriate value obtained from the approxi-mate relationship of Brinell hardness to tensile strength included in ASTM.

Specification A-370.

These additional valve yokes are on a wide range of

  • valve sizes and are from a number of different purchase orders placed with Malcolm over a period of at least ten months during 1974 and 1975.

Thus, it appears that the problem is not isolated to one heat of material or to one short time period.

Anchor Darling intends to replace the defective valve yokes at Susquehanna and to begin a testing program *at other nuclear power plants under construction where valves with valve yokes cast by Malcolm have been provided.

-i

!EB 80-21 Page 2 of 3 Since Malcolm Foundry Company, Inc., is no longer in business, the NRC staff cannot determine directly if Malcolm has provided valve parts to other valve manufacturers for use in nuclear power plants.

Actions To Be Taken by Addressees:

For all power reactor licensees or holders of construction permits the following actions are required:

1.

Determine if any of the active valves in use or planned for use in safety-related systems at your facility have valve parts cast by Malcolm Foundry Company, Inc.

If no valves are identified as having. potentially faulty material, indicate. that this is the case and ignore the remaining questions.

2.

Licensees having active safety-related valves with potentially faulty material shall immediately visually inspect for cracks all normally accessible valve parts (i.e., those which can be inspected during reactor operation).

3.

Licensees or permit holders having active safety-related valves with potentially faulty material shall identify the manufacturer(s) of these valves and either:

a.

Verify that all valve parts cast by Malcolm have mechanical properties in* accordance with the ASTM material sped fi cat ion; if such is not the case, then comply with either b. or c. below also.

b.

Replace the defective materials and/or valves.

c.

Identify any other corrective actions that may be exercised and the basts for such actions.

For plants with an operating license, the results of your initial determination (item 1), visual inspection results (item 2), a list of affected valve manu-facturers, your planned action (item 3), and the schedule for accomplishing this action shall be reported within thirty days of the date of this bulletin to the Director of the appropriate NRC Regional Office with a copy sent to the NRC Office of Inspection and Enforcement, Division of Reactor Construction Inspection, Washington, DC 20555.

For plants with a construction permit, the results of your initial determination (item 1), a list of affected valve manufacturer(s), your planned action (item 3) and the schedule for accomplishing this action shall be reported within sixty days of the date of this bulletin to the Director of the appropriate NRC Regional Office with a copy sent to the NRC Office of Inspection and Enforcement, Divi~ion of Reactor Construction Inspection, Washington, DC 20555.

IEB 80-21 Page 3 of 3 Compliance with this bulletin by the licensees does not relieve the affected valve manufacturers from the reporting requirements of 10 CFR Part 21.

If you desire additional information regarding this matter, please contact the appropriate IE Regional Office.

Approved by GAO, 8180225 (R0072); clearance expires November 30, 1980.

Approval was given under a blanket clearance specifically for identified generic problems.

IE Bulletin No~ 80-21 November6, 1980 Bulletin No.

80-22 Revision 1 to 79-26 Revision 1 to 80-19 80-20 80-19.

. 80-18 Supplement 3 to 80-17 Supplement 2 to 80-17 Supplement 1 to 80-17 RECENTLY ISSUED IE BULLETINS Subject

.Date Issued Automation Industries,*

Model 200-520-008 Sealed-Source Connectors 9/12/80

  • Boron*Loss from 8/29/80 BWR Control Blades Failures of Mercury-8/15/80 Wetted Matrix Relays in Reactor Protective Systems of Operating Nuclear Power Plants Designed by Combustion Engineering Failures of Westinghouse 7/31/80 Type W-2 Spring Return to Neutral Control Switches Failures of Mercury-7/31/80 Wetted Matrix Relays in Reactor Protective Systems of Operating Nuclear Power Plants Designed by Combustion Engineering Maintenance of Adequate 7/24/80 Minimum Flow Thru Centrifugal Charging Pumps Following Secondary Side High Energy Line Rupture

.Failure of Control Rods 8/22/80 to Insert During a Scram at a BWR Failure of Control Rods 7/22/80 to Insert.During a Scram at a BWR Failure of Control Rods 7/18/80

. to Insert During a Scram at a BWR Issued To All holders of a radiography license All holders of a BWR power reactor OL All holders of a power reactor OL or CP All holders of a power reactor OL or CP All holders of a

. power reactor OL or CP All holders of a PWR power reactor OL or CP All holders of a BWR power reactor OL or CP All holders of a

. BWR power reactor OL All holders of a BWR power reactor OL or CP