ML18082A674

From kanterella
Jump to navigation Jump to search
Forwards Response to 800404 Confirmatory Orders Re Loss of non-Class IE Instrumentation & Control Power Bus.Info Written for Unit 1,but Also Applicable for Unit 2,except as Noted.Includes Response to IE Circular 79-02.Affidavit Encl
ML18082A674
Person / Time
Site: Salem  
Issue date: 06/27/1980
From: Schneider F
Public Service Enterprise Group
To: Moseley N
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
IEC-79-02, IEC-79-2, NUDOCS 8007030249
Download: ML18082A674 (36)


Text

r

  • Frederick W. Schneider Vice President Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 201/430-7373 Production June 27, 1980 Mr. Norman c. Moseley, Director Division of Reactor Operations Inspection
u. s. Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. Moseley:

CONFIRMATORY ORDERS LOSS OF NON-CLASS l~E INSTRUMENTATION AND CONTROL POWER BUS DURING OPERATION SALEM GENERATING STATION UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 Pursuant to the Confirmatory Orders dated April 4, 1980 issued to Facility Operating License No. DPR-70 and Facility Construction Permit No. CPPR-53, we hereby submit our response to the in-formation requested in Attachment A of the Confirmatory Orders.

The information was written with. regard to Unit No. 1, but the response is applicable to both Salem Units except as noted.

If you have any further questions, please do not hesitate to contact us.

Attachment A:

Attachment B:

Sincerely, Summary of Failure Analysis Response to NRC IE Circular 79-02 cc Mr. Boyce H. Grier, Director U. s. Nuclear Regulatory Commission Office of Inspedtion and Enforce~ent Region 1 631 Park Avenue King of Prussia, PA 19406 80 070 30~7'1. p

1.

~ '

t STATE OF NEW JERSEY)

)

SS:

COUNTY OF ESSEX

)

FREDERICK W. SCHNEIDER, being duly sworn according to law deposes and says:

I am a Vice President of Public pervice Electric and Gas Company, and as such, I signed the Response to the Confirmatory Order issued on April 4, 1980 to Facility Operating License No. DPR-70 and F~cility Construction Permit No. CPPR-53.

The matters set forth in said change request are true to the best of my knowledge, information, and belief.

~/A)U->

FREDERI~SCHNEIDER Subscribed and sworn to before me this~""-day of~, 1980

~£.

)?ta~w~uJ Notary Public of New Jersey My commission expires on &e~. /. /fJ\\3

I' RESPONSE TO CONFIRMATORY ORDERS ISSUED ON APRIL 4, 1980 SALEM GENERATING STATION UNIT NOS. 1 AND 2 FACILITY OPERATING LICENSE NO. DPR-70 FACILITY CONSTRUCTION PERMIT NO. CPPR-53

' - NRC REQUEST

1.

Review the Class lE and Non-Class lE buses supplying power to safety and non-safety related instrumentation and control systems which could affect the ability to achieve a cold shutdown condition using existing proce-dures or procedures developed under Item 2 below.

For each bus:

A.

Identify and review the alarm and/or indication pro-vided in the control room to alert the operator to the loss of power to the bus.

B.

Identify the instrument and control system loads connected to the bus and evaluate the effects of loss of power to these loads including the ability to achieve a cold shutdown condition.

C.

Describe any proposed design modifications resulting from these reviews and evaluations, and your pro-posed schedule for implementing those modifications.

RESPONSE

l.A.

The loss of power to any 115v AC Vital Instrument Bus (VIB) or essential controls panel (11 MAC and 12 MAC) is alarmed on both the overhead and auxiliary annunci-ators.

The overhead alarms for each bus/panel are grouped into a single annunciator window to provide a "systems level" alarm.

The purpose of this alarm win-dow is to alert the control room operator to an elec-trical system problem and to direct attention to the auxiliary annunciator for additional specific informa-tion.

The auxiliary annunciator provides individual alarms for each bus/panel.

The alarm message print-outs are:

lA 115v AC Vital Instrument Bus Loss of Voltage lB 115v AC Vital Instrument Bus Loss of Voltage lC 115v AC Vital Instrument Bus Loss of Voltage lD 115v AC Vital Instrument Bus Loss of Voltage llMAC 115v AC Dis tr. Cabinet Loss of Voltage 12MAC 115v AC Distr. Cabinet Loss of Voltage In addition to loss of voltage alarms, inverter fail-ure alarms for each VIB are provided on individual overhead annunciator windows as follows:

lA VTL. BUS INVERT. FAILURE/FUSE BLOWN lB VTL. BUS INVERT. FAILURE/FUSE BLOWN lC VTL. BUS INVERT. FAILURE/FUSE BLOWN lD VTL. BUS INVERT. FAILURE/FUSE BLOWN

/

,. The auxiliary annunciator also provides alarms for the failure of the power sources which supply the buses/pan-els.

These alarms are:

lA Vital Instr. Bus Inv. Pwr. Supply Loss of AC Output lB Vital Instr. Bus Inv. Pwr. Supply Loss of AC Output lC Vital Instr. Bus Inv. Pwr. Supply Loss of AC Output lD Vital Instr. Bus Inv. Pwr. Supply Loss of AC Output 11 and 12 Station Essential Controls Inverters Pwr.

Supply Loss of AC Output The above mentioned power sources which supply the in-verters for the VIB's and essential MAC Panels are equipped with auctioneering devices which automatically shift the affected inverter input connection to a d.c.

power source in the event the power supply output is lost.

The loss of power to a non-essential control panel (13 MAC and 14 MAC) is alarmed on the auxiliary annuncia-tor.

The alarm messages are:

13 MAC 115v AC Distr. Cabinet Loss of Voltage 14 MAC 115v AC Distr. Cabinet Loss of Voltage The non-essential control panels are not supplied by in-verters.

In addition to the alarms on the overhead annunciator related to bus/panel voltage problems, an alarm window is provided to notify the control room operator that the auxiliary annunciator is printing.

Therefore, for those failures which are not alarmed on the overhead annuncia-tor, the operator is referred to the auxiliary annunciator.

B.

The VIB's and MAC panels can be supplied by a backup 115v AC source in the event of an inverter failure.

Manual action is required to accomplish the transfer to the backup source.

The transfer can be readily achieved before the plant approaches cold shutdown.

Therefore, it is not anticipated that the plant will have to achieve the cold shutdown condition without the services provided by any one VIB or MAC Panel.

.. However, for the purpose of analysis it was assumed that the plant must possess the ability to safely achieve cold shutdown with one VIB or one MAC Panel unavailable.

Consequently, the VIB's and MAC panels were analyzed on a circuit by circuit basis to determine the failure modes of bus loads and alarms/annunciations associated with a loss of power.

The analysis included the following:

1.

Circuit Loads

2.

Failure modes of transmitters, indicators, re-corders, signal comparators, and other equipment contained in instrumentation and control loops.

J.

Failure modes of valves and valve control circuits.

4.

The failure modes of status indicating circuits.

5.

The effect of a loss of power on alarm cir-cuitry (loss of alarm capability, erroneous alarms, valid alarms).

The results of the analysis were reviewed by engineering and Salem operations personnel, and expanded beyond the failure modes of individual circuit loads to include system interrelationships and the cumulative effects of various individual circuit failures.

Particular atten-tion was directed towards the ability of Salem Station personnel to safely bring the plant to cold shutdown.

The analysis review also included alternate indication available to the control room operators and alternate equipment which could be operated given the loss of a VIB or MAC Panel.

It was determined that the failure of any one VIB or MAC panel would not prevent station oper-ating personnel from taking the plant from power opera-tion to cold shutdown in a safe manner.

Attachment A is a summary of the detailed analysis for those systems which may be or are required to be used in the process of taking the plant to cold shutdown.

It describes only the most important effects of a postu-lated loss of power to a VIB or MAC Panel.

C.

The tables of Attachment A include information pertain-ing to design modifications which are being evaluated.

The design modifications being considered are not due to any inability to achieve cold shutdown, but rather to enhance the availability of information presented to the control room operator and to further aid the operator in bringing the plant to cold shutdown.

The desirability of modifications to existing procedures is dependent upon the degree of design modifications to be implemented for those items identified in Attachment A.

It is expected that the evaluation of the potential design modifications being considered will be completed by August 1, 1980.

The actual implementation of any de-sign modifications considered can be expected to be com-pleted during the first refueling outage for Salem 2 and the third refueling outage for Salem 1 (second refueling outage scheduled for July 1980).

NRC REQUEST

2.

Prepare emergency procedures or review existing ones that will be used by control room operators, including procedures required to achieve a cold shutdown condi-tion, upon loss of power to each class lE and non-class lE bus supplying power to safety and non-safety related instrument and control systems.

The emergency proce-dures should include:

A.

The diagnostics/alarms/indicators/symptom re-sulting from the review and evaluation conducted per item 1 above.

B.

The use of alternate indication and/or control circuits which may be powered from other non-class lE or class lE instrumentation and control buses.

C.

Methods for restoring power to the bus.

Describe any proposed design modification or administra-tive controls to be implemented resulting from these procedures, and your proposed schedule for implementing the changes.

RESPONSE

2.A.

An alarm book is provided in each Salem control room.

The book includes information pertaining to the over-head annunciator alarms described in the response to Item 1.

Whenever an alarm occurs, the operator may refer to this book for additional information and guidance.

The alarm book contains information per-taining to:

1.

Probable causes of the alarm.

2.

Automatic actions which result due to the alarm.

3.

Immediate actions to be performed.

4.

Supplemental actions to be performed.

B.

Information related to this topic is included as part of the response to Item 1.

C.

Methods for restoring power to a VIB or essential con-trols panel are included as part of the required opera-tor actions mentioned in Part A.

Until a decision is reached regarding any design modifica-tions and implementation of those modifications, the results of the analysis, in tabular form, will be provided to the Salem Operations Department to be used in conjunction with existing operating procedures.

Any required revisions to existing station operating procedures and/or preparation of new procedures will be accomplished according to a schedule consistent with that of any design modifications deemed advantageous.

NRC REQUEST

3.

Re-review IE Circular No. 79-02, Failure of 120 Volt Vital AC Power Supplies, dated January 11, 1979 to in-clude both class lE and non-class lE safety related power supply inverters.

Based on a review of operating experience and your re-review of IE Circular 79-02, de-scribe any proposed design modifications or administra-tive controls to be implemented as a result of the re-review.

RESPONSE

3.

The analysis performed as required by NRC IE Circular 79-02 has been re-reviewed with no new information to report.

Since the inverters used to supply the essen-tial controls panels (11 MAC and 12 MAC) are of the same type model/manufacturer as utilized to supply the VIB's, the circular response is applicable to 11 and 12 MAC Panel inverters.

The original response to IE Circular 79-02 is attached (Attachment B).

As a result of inverter operating histories at Salem 1, the Engineering Department is presently engaged in a progam to improve the availability and reliability of VIB bus and MAC Panel inverters utilized at both Salem Units.

RB:lb 6/16/80 M T808/4 1/7

SYSTEM Auxiliary Feedwater*

Chemical and Volume Control M P80 60 01 1/2 COMPONENT

  1. 11 AFW Pump Suet. Press.

Disch. Press.

XMTRS Pwr. Supply

  1. 13 + 14 S.G. AFW Flow XMTRS. Pwr. Supply.
  1. 13 + 14 S.G. Inlet Valves (13AF21 + 14AF21)

Control AFW Storage Tk. Lvl.

XMTR Pwr. Supply Letdown Line Temp.

Indicator Controller Primary Water Storage Tk. Lvl.

XMTR Pwr. Supply B.A. Magnetic Flow XMTR. + Indicator Pwr.

Supply VCT LO-LO Lvl. Alarm ATTACHMENT A -

BUS FAILURE ANALYSIS lA VIB EFFECT OF FAILURE Loss of Info. Only.

Pump Start-Stop Not Inhibited.

s.G. Inlet VA's (13AF21 +

14AF21) Prevented From Opening Due to Loss of Disch. Press. Sig.

Loss of Indication Only No Sys. Malfunction.

Loss of Valve Control Loss of Indication Only Letdown Flow Diverted From Mixed Bed Demin. 's to VCT, Loss of Normal Letdown Flow Path

  1. 11 + 12 Prim. Wtr. M-U Pumps Stop if in Auto Loss of B.A. Flow Control.

Flow Cont. VA. ICV172 Opens.

Fully Supplying B.A. Blender

+ Chg. Pmps.

Loss of all B.A. Flow Indication in C.R.

Alarm Activated + Causes Isolation of Chg. Pumps From VCT and Opening of ISJl +

ISJ2.

Chg. Sys. Draws Suction From RWST.

Boron Now Injected Via Chg. PMP/PMPS

@2000 PPM Minimum.

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE S.G. Level Ind., Pump Start-Stop + Motor Amps Ind.

Available on Control Console.

  1. 12 and 13 AFW Pumps Operation and Indication Available.

Manual Press. Override (Manual Operation) Available.

s.G. Lvl. Ind. Available on Cont. Console S.G. Lvl. Ind. Available on Cont. Console

  1. 12 + 13 AFW Pumps Available Local Indication Available None Local Lvl. Ind. Available Prim. Wtr. M-U Pumps can be Operated in Manual Mode.

None None DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None

_=-:J

SYSTEM Component Cooling*

Containment Ventilation*

Main Steam Pressurizer M PBO 60 01 3/4 COMPONENT

  1. 11 CCW HX Temp.

Controller CCW Pmps Low Disch.

Press to #11 HX Alarm CH. I Cont. Press Indicator + XMTR Pwr.

Supply

  1. 11 Fan Coil Unit Outlet Temp + Flow XMTRS Pwr.

Supply

  1. 11 Fan Coil Unit S.W.

Control Flow XMTR. Pwr.

Supply

  1. 11,12,13,14,15 Fan Coil Units Leak Detect. Ind's.

+ 11 F.C. Unit Leak Detect. XMTR. Pwr. Supply Atmos. Relief Va. llMSlO Press XMTR. Pwr Supply CH. II 1st Stage Turb.

Press. Indicator Pwr.

Supply PRZ Press. CH. I XMTR +

Indicator Pwr. Supply PRZ Press Signal Comparator

  1. 13 Spray Line Temp.

Ind. + 11 Spray Line Temp. Ind. + XMTR. Pwr.

Supply, PRZ Liquid Temp.

Indicator + XMTR + Vapor Temp. Indicator Pwr.

Supply lA VIB EFFECT OF FAILURE Loss of all #11 CCW HX Temp. Ind.

Alarm Caused by Ckt Loss.

No System Malfunction.

Loss of Indication Loss of Indication Only.

No System Malfunction.

Loss of All s.w. Flow Control. Speed Control Available Loss of Leak Detection Information Valve Receives Signal to Close Loss of 1st Stage CH. II Press. Indication No System Malfunction Loss of CH. I Info.

No System Malfunction Due to Pwr. Loss Loss of Ability to Open, in Auto Mode, Pwr. Oper. Relief VA.

1PR2 Loss of Info.

No System Malfunction.

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE High Temp. Alarms for Equip.

Supplied are Operational.

LO-CCW Flow Alarms on Equip.

Supplied by System Available.

  1. 12 CCW HX Available
  1. 12 CCW HX Available CH'S II, III, IV Available
  1. 12, 13, 14, 15 F.C. Units

+ Ind's. Available

  1. 's 12,13,14,15 F.C. Units+

Indication Available None Remote Manual (Cont. Console)

Control Functional.

Local Control Available.

Safety Valves Functional.

CH. I Indication Available CH's II, III, IV Indication Available 1PR2 can be Operated in Manual.

lPRl Operation Available.

PRZ Press., Lvl +Surge Line Temp. Available DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None None None None

SYSTEM Pressurizer (Cont'd)

Protection System Reactor Coolant Residual Heat Removal*

,, rinn r.n 111

  • ~ii; COMPONENT PRZ Lvl CH. I XMTR +

Indicator Pwr. Supply Demultiplexer Power Supply 11, 12, 13, 14 RC Loops CH. I Flow XMTRS +

Indicators Power Supply 11 RC Loop Dif f. Temp.

Diff. Temp. Setpoints XMTRS. + Indicators W.R. Hot Leg Temp.

W.R. Cold Leg Temp.

Indicators Power Supply RCS Temp. + Press Indicators Pwr. Supply RC Hot Leg Press.

XMTR. PT-405

  1. 11 RHX Outlet Flow +
  1. 11 RHR Injection Flow Indicators + XMTRS.

Power Supply 11 RHR Loop Cooldown Control Valve llRHlB 11 RHR Pump C.C.W.

Flow Switch Containment Sump Lvl.

Indication Ckt.

11 RIIR Pump Disch.

Press. Indicator Pwr.

Supply lA VIB EFFECT OF FAILURE Loss of CH. I Info.

j No System Malfunction.

Loss of all Indication oh Status Panel Pertaining to Reactor Trip Logic Loss of CH. I Indication.

No System Malfunction.

Loss of all Loop 11 Temp.

Information Loss of Temp. + Press. Ind.

for "POPS" Loss of PT-405 Functions.

Loss of POPS CH. I Loss of Opening Permissive For RHR Cool Down Isolation Valve 1RH2.

Loss of Hot Leg Press Ind~

Loss of Indication for 11 RHR Loop Loss of Valve Control.

Valve Remains in last Position.

Receive Low CCW Flow Alarm on Cont. Console.

l\\larm is Due to Pwr. Loss.

Loss of Cont. Sump Lvl. Ind.

Loss of Disch. Press.

Indication ALTERNATE INDICATION/

EQUIPMENT AVAILABLE CH's II + III Indication Available None CH's II + III Indication Available on Cont. Console None Alternate Temp. + Press.

Indication Available on Cont.

Console Pops CH II Available.

To Open 1RH2, Must Restore Pwr. to Ckt. or Bypass Permissive Contact in Valve Motor Control Ckt.

Problem with 1RH2 Identified in LER 76-04.

Alternate Hot Leg Press Ind.

Available on Cont. Console

  1. 12 RHR Loop Available
  1. 12 RHR Loop Available
  1. 12 RHR Loop Available Alternate Level Indication Available on Cont. Console
  1. 12 RHR Loop Available DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None None None None

SYSTEM Safety Injection*

Service Water*

Steam Generator COMPONENT 11 SI Pump c.c.w. Flow Switch

  1. 's 11 + 12 Accumulators Level + Press. XMTRS. +

Indicators Power Supply

  1. 12 S.W. HDR. Press XMTR

+ Indicator Pwr. Supply (Unit l Only)

  1. 21 SW HDR Press. XMTR +

Indicator Power Supply (Unit 2 Only)

  1. 's 11, 12, 13, 14 S.G.'s CH. I Steam Flow F.W. Flow Press.

Level XMTRS + Indicators Power Supply (Not All Parameters For All SG's on CH. I) lA VIB EFFECT OF FAILURE Receive Low CCW Flow Alarm.

Alarm is Due to Power Loss.

Loss of 11 + 12 Accum.

Lvl. + Press Ind.

Loss of all Cont. Room Ind.

for #12 SW !!DR.

  1. 's 14, 15, 16 SW Pumps Auto Control Remains Functional Loss of all Cont. Room Ind.

for #21 SW HDR.

s.w. Pumps 21, 22, 23 Auto Control Remains Functional Loss of CH I Indications (Where Applicable)

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE 12 SI Pump Available Alternate Ind. Available on Cont. Console for 11 + 12 Accum. Lvl. + Press.

  1. 11 HDR Press Ind. Available in Cont. Room
  1. 22 HDR Press Ind.

Available in Cont. Room Alternate Indications for all Parameters Available on CH's II, III, or IV DESIGN MODIFICATION TO BE EVALUATED None None None None None

  • Due to the loss of this bus, SEC Train A is lost.

Therefore, no ESF Train A equipment will automatically start/shift modes of operation (if required).

Adequate redundancy is provided for all systems affected (SEC Train Band SEC Train c functional).

Manual control for all affected equipment is available.

M PBO 60 01 7/8

SYSTEM Auxiliary Feedwater*

Chemical and Volume Control M P80 60 01 9/10 COMPONENT

  1. 12 AFW Pump Suet. Press.

Disch. Press.

XMTRS. Pwr. Supply

  1. 11 + 12 AFW Flow XMTRS **

Pwr. Supply

  1. 11 + 12 S.G. Inlet Valve (11AF21 + 12AF21) Control AFW Pumps Suet. Press.

XMTR. Pwr. Supply

  1. 11 Chg. Pump CCW Flow Switch.

lB VIB EFFECT OF FAILURE Loss of Info. Only.

Pump Start-Stop not Inhibited.

S.G. Inlet VA's (11AF21 + 12AF21) Prevented From Opening Due to Loss of Disch. Press Sig.

Loss of Indication Only No Sys. Malfunction Due to CKT. Loss.

Loss of Valve Control Loss of Indication.

No Sys.

Malfunction Due to Ckt Loss.

Low CCW Flow Alarm.

Alarm is Due to Pwr. Loss.

Excess Letdown HX Outlet Loss of Valve Control.

Flow Control Valve 1CV132 Valve Normally Closed +

Remains in Last Position.

Loss of Excess Letdown Flowpath.

Excess Letdown Temp. +

Press XMTRS + Indicators Power Supply Letdown Isolation Valves 1CV3, 1CV4, 1CV5, 1CV277

  1. 11 B.A. Tank Lvl. +

Temp. XMTRS. + Ind's.

Pwr. Supply, Recirc. Flow Control Valve 11CV160 Control Loss of all Excess LTDN.

Indication Loss of Normal Letdown Flowpath.

Loss of All Indication for

  1. 11 B.A. Tank.

Loss of Control 11CV160.

Valve Remains in Last Position ALTERNATE INDICATION/

EQUIPMENT AVAILABLE S.G. Lvl. Ind., Pump Start-Stop + Motor Amps. Ind.

Available on Cont. Console.

  1. 's 11 + 13 AFW Pumps Operation and Indication Available.

Manual Press.

Override (Manual Operation)

Available.

S.G. Lvl. Ind. Available on Cont. Console S.G. Lvl. Ind. Available on Cont. Console

  1. 's 11 + 13 AFW Pumps Available Individual Suet. Press. Ind.

for all AFW Pumps Except #12 (See Above) Available on Cont. Console

/

  1. 's 12 + 13 Chg Pumps Available None None None
  1. 12 B.A. Tank+ Recirc.

Control Available DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None None

SYSTEM Component Cooling*

Containment Ventilation*

Main Steam Pressurizer M PBO 60 01 11/12 COMPONENT

  1. 12 CCW HX Temp. Ind.

Controller, Disch. Temp.,

Disch. Press to #12 HX (Alarm) XMTRS. +

Indicators Pwr. Supply lB VIB EFFECT OF FAILURE Loss of Temp. Ind., Loss of High Temp. Alarm, Receive Low Disch. Press. Alarm.

CH. II Containment Loss of Indication Pressure XMTR + Indicator Pwr. Supply

  1. 's 12 + 14 Fan Coil Units S.W. Flow Control XMTRS Pwr. Supply
  1. 12 Fan Coil Unit Leak Detection XMTR Pwr.

Supply

  1. 's 12 + 14 Fan Coil Units Outlet Wtr. Temp. +

Flow XMTRS Pwr. Supply CH. II First Stage Turbine Press XMTR.

Power Supply Atmos. Steam Relief Valve 12MS10 Press. XMTR. Pwr.

Supply Pressurizer Level CH. II XMTR. + Indicator PWR Supply PRZ Press. CH. II XMTR

+ Indicator Pwr. Supply PRZ Press. Signal Comparator PRZ Htrs.

Loss of All Flow Control.

Speed Control Available.

Loss of Indicat*ion Only Loss of Indication Only.

System Malfunction.

Ckt. Loss Makes Up Some Permissives for Steam Dump Valve Receives Signal to Close Loss of CH. II Ind.

Loss of CH. II Ind.

No Loss of Ability to Open in Auto Mode Pwr. Ooer.

Relief Valve lPRl Pwr Loss Causes Low PRZ Lvl. Alarm Which Removes PRZ Htr Bkr. Close Permissive on Regular + B-U Htrs.

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE 11 CCW HX Available.

High Temp Alarms for Equip Supplied are Operational.

CH's I, III, IV Indication Available

  1. 's 11, 13, 15 F.C. Units+

Indication Available

  1. 's 11, 13, 14, 15 F.C. Units Leak Detection Indication Available
  1. 's 11,13,15 F.C. Units+

Ind's Available CH. I Ind. + Functions Available Remote-Manual (Cont. Console)

Control Functional Local Control Available.

Safety Valves Operable CH's I + III Ind. Available CH's I, III, IV Ind. Available 1PR2 Operation Available.

lPRl can be Operated in Manual.

Local Control for Controlled Group Available


*~*~.... ~-~-,......,,..~

DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None None None None

SYSTEM Pressurizer (Cont.)

Reactor Coolant Residual Heat Removal*

M P80 60 01 13/14 COMPONENT PRZ Relief Tank Level Press.

Temp.

XMTRS + Indicators Pwr.

Supply

  1. 's 11, 12, 13, 14 RC Loops CH. II Flow MTRS. +

Indicators Pwr. Supply lB VIB EFFECT OF FAILURE Loss of all PRT Indication Except Associated Valve Position Indications.

Loss of CH. II Indication No System Malfunction Due to Ckt. Loss.

  1. 12 RC Loop Loss of all Loop 12 Temp.

Diff. Temp.

Information Dif. Temp. Setpoints XMTRS + Indicators, W.R. Hot Leg Temp.

W.R. Cold Leg Temp.

Indicators Pwr.

Supply RCS Temp. + Press. XMTRS.

+ Indicators Pwr. Supply Loss of Temp + Press Ind.

Loss of PT-403 Functions R.C. Hot Leg Press Loss of Pops CH. II XMTR. PT-403 Loss of Opening Permissive

  1. 12 RHX Outlet Flow XMTR.

+ Indicator + #12 RHR Injection Flow Indicator Power Supply 12 RHR Loop Cooldown Control Valve 12 RH18 12 RHR Pump C.C.W.

Flow Switch For RHR Cooldown Isolation Valve lRHl.

Loss of Hot Leg Press. Ind.

Loss of Indication for 12 RHR Loop Loss of Valve Control.

Valve Remains in Last Position.

Receive Low CCW Flow Alarm on Cont. Console. Alarm is Due to Pwr. Loss ALTERNATE INDICATION/

EQUIPMENT AVAILABLE None CH's I & III Indication Available on Cont. Console None Alternate Temp. + Press Ind. Available on Cont.

Console Pops CH. I Available to Open lRHl.

Must Restore Pwr. to Ckt. or Bypass Permissive Contact in Valve Motor Control Ckt.

Problem with lRHl Identified in LER 76-04.

Alternate Hot Leg Press Ind.

Available on Cont. Console.

  1. 11 RHR Loop Available
  1. 11 RHR Loop Available
  1. 11 RHR Loop Available DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None

SYSTEM Residual Heat Removal* (Cont.)

Safety Injection*

Steam Generator COMPONENT Containment Sump Lvl. Indication Ckt.

  1. 12 RHR Pump Disch.

Press XMTR + Indicator Pwr. Supply RHR Cooldown Recirc.

Flow XMTR + Indicator Pwr. Supply RWST Level XMTR +

Indicator Pwr. Supply

  1. 's 11 + 12 Accumulators Level + Press. XMTRS +

Indic~tors Pwr Supply Chg. Pumps SI Disch.

Flow XMTR + Indicator Pwr Supply

  1. 's 11, 12, 13, 14 S.G. 's CH. II Steam Flow F.W. Flow Press Level XMTRS + Indicators Power Supply (Not All Parameters For all S.G.'s on CH. II) lB VIB EFFECT OF FAILURE Loss of Containment Sump Level Indication Loss of Indication Loss of RHR Sys. Cooldown Flow Indication.

Loss of RWST Level Ind.

Loss of Indication Loss of SI Disch Flow for Chg Pumps Loss of C~. II Indications (Where Applicable)

  1. 12 S.G. Steam Dump to Loss of Auto Control ATMOS, CH II Valve Demand 12 MSlO.

XMTR Pwr Supply ALTERNATE INDICATION/

EQUIPMENT AVAILABLE Alternate Level Indication Available on Cont. Console 11 RHR Pump Available

  1. 11 RHR Loop Flow Indication Available.

Other Flow Paths for 11 RHR Loop Must be Isolated (Min. Recirc., Etc.)

For Flow Ind. to be Accurate.

Alternate Level Indication Available on Cont. Console Alternate Level + Press Indication Available on Control Console BIT Disch. Press Ind Available on Cont. Console Alternate Indications for all Parameters Available on CH's I, III, or IV Must take Manual Control of Valve DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None

  • Due to the loss of this bus, SEC Train B is lost.

Therefore, no ESF Train B equipment will automatically start/shift modes of operation (if required).

Adequate redundancy is provided for all systems affected (SEC Train A and SEC Train C functional).

Manual control for all affected equipment is available.

M PBO 60 01 15/16

SYSTEM Auxiliary Feedwater Chemical + Volume Control Component Cooling*

M P80 60 01 17/18 COMPONEN'r U3 AFW Pump Suet. Press.

Disch. Press.

Steam Press.

Speed Speed Demand XMTRS.

Power Supply S.G. Inlet Valves llAFll l 2AF1 l l3AF'll 14AFll Control Ckts, Pwr. Supply AFW Alternate Suet.

Press. XMTR. Pwr Supply

  1. 12 8,A, Tk. Temp.

Ind. Controller Pwr. Supply c.c.w. Flow Alarms for #12 SI Pump + #12 Chg. Pump c.c.w. Surge Tk. A Level XMTR + Indicator Power Supply

  1. 11 CCW HX Outlet Temp. XMTR + Indicator Power Supply
  1. 11 RHX CCW Outlet Flow XMTR + Indicator Pwr. Supply lC VIB /

EFFECT OF FAILURE Loss of all Indication Loss of Remote Speed Control Loss of Valve Control Valves Normally Open Loss of Alt. Suet. Press Ind.

I

/

Loss of #12 B.A. Tk. Temp.

Ind. in Control Room Loss of Auto Htr. Control Receive Low CCW Flow Alarms.

Alarms Due to Pwr. Loss.

Loss of Ind. in -Cont. Room.

Loss of Temp. Ind. in Cont. Room Loss of Ind. in Cont. Room ALTERNATE INDICATION/

EQUIPMENT AVAILABLE

  1. 11 + 12 AFW Pumps Operable with Indication Available Local Speed Control Available
  1. 11 + 12 AFW Pumps Operable With Indication + Valve Controls Available Individual Suet. Press. Ind.

Available for #11 + 12 AFW Pumps.

Suet. Press. Ind. for 13 AF.W Pump Affected by Loss of this Bus Manual Htr. Control Available

  1. 11 B.A. Tk. Available
  1. 11 SI + #11 Chg Pumps Available Local Indication Available B c.c. Surge Tk +

Indication Available

  1. 12 CCW HX Available
  1. 12 RHX Available DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None

SYSTEM Containment Ventilation*

Main Steam Pressurizer M PBO 60 01 19/20 COMPONENT Containment Press. CH.

II I XMTR. + Indicator Pwr. Supply

  1. 13 Fan Coil Unit Leak Detection XMTR. Pwr. Supply Cont. Diff. Press. Alarm XMTR. Pwr Supply
  1. 's 13 + 15 Fan Coil Units S.W. Control Ckt.
  1. 's 13 + 15 F.C. Units Outlet Wtr. Temp. +

Flow XMTRS Pwr. Supply Steam Dump Control Atmos. Steam Relief Valves 12MS10, 13MS10 Control Atmos. Steam Relief Valves 13MS10 + 14MS10 Press. XMTRS. Pwr. Supply Atmos. Steam Relief Valve 12MS10 Setpoint + Demand Indicators Pwr. Supply PRZ Press CH. III XMTR

+ Indicator Power Supply PRZ LVL. CH. III XMTR.

+ Indicator Pwr. Supply lC V I13 EFFECT OF FAILURE Loss of CH. III Press. Ind.

Loss of Ind. in Cont. Room Loss of Diff. Press. Ind.

in Cont. Room Loss of Hi-Diff. Press.

Alarm Loss of all Flow Control Speed Control Remains Operational Loss of Indication No Sys. Malfunction Due to Ck t. Loss.

Steam Dump Capability Lost for both Train A and B Due to Loss of "Circulators in Service Permissive Loss of Auto or Remote Manual Control of 12MS10 + 13MS10.

Loss of Control May Cause S.G. Diff. Press. SI 14MS10 Receives Signal to Close.Loss of Control (see above) 13MS10 Loss of Indication Loss of CH. III Indication Loss of CH. Ill Indication ALTERNATE INDICATION/

EQUIPMENT AVAILABLE CH's I, II, IV Indication Available in Control Room

  1. 11, 12, 14, 15 F.C. Unit Leak Detection Indication Available in Cont. Room Cont. Press. Ind. Available in Cont. Room
  1. 's 11, 12, 14 F.C. Un~ts s.w. Control Operational
  1. 's 11, 12, 14 F.C. Units Available with Indication Atmos. Relief Valves MSlO's Can be Used (llMSlO + 14MS10) llMSlO + 14MS10 Available for Operation.

Local Control 12MS10 + 13MS10 Available.

Safety Valves Operable.

llMSlO Available for Auto-Man. Control.

Local Control All MSlO Valves Available.

Safety Valves Operable.

S.G.'s Press. Indication Available CH's I, II, + IV Indication Available in Cont. Room CH's I, II Indication Available in Cont. Room DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None None None None

I SYSTEM Pressurizer (Cont'd)

Reactor Coolant Residual Heat Removal*

Safety Injection*

M P80 60 01 21/22 COMPONENT PRZ Pwr. Oper. Relief Va. 1PR2 Control PRZ Spray Valves

!PS! + 1PS3 Control

+ R.C. Press. Demand XMTR + Indicator Pwr. Supply PRZ Spray Line Temp.

LOOP 13 + Vapor Temp XMTRS. Pwr. Supply PRZ Safety Valve Disch. Temp. Loop 12 XMTR Pwr. Supply

  1. 's 11, 12, 13, 14 R.C.

Loops CH. III Flow XMTRS +

Indicators Pwr. Supply

  1. 13 RC Loop Diff. Temp.

Diff. Temp. Setpoints XMTRS + Indicators W.R. Hot Leg Temp.

W.R. Cold Leg Temp.

Indicators Pwr. Supply R.C. Press XMTR +

Indicator Pwr Supply R.C. Loop's 11, 12, 13, 14 Avg Temp Indicators +

Signal Comparators Pwr Supply ill RHR Pump Disch.

Press. XMTR. Pwr. Supply

  1. 12 RHR Loop Injection Flow XMTR.

Pwr Supply

  1. 's 13 + 14 Accumulators Level + Pres. XMTRS +

Indicators Pwr. Supply lC VIB EFFECT OF FAILURE Loss of Auto -

Open Capability for 1PR2 Loss of Auto-Man. Cont.

lPSl + 1PS3 Valves Normally Closed Loss of PRZ HTR. Control Loss of all Pertinent Spray Info Except PRZ Liq. Temp + Surge Line Temp Indications Loss of Ind. in Cont. Room Loss of CH. III Indication No Sysem Malfunction Due to Ckt. Loss Loss of all Loop 13 Temp.

Information Loss of Press. Ind.

Loss of Tavg. Indication for all Loops (Indicators +

Recorders Affect.ed)

Loss of Indication Loss of Indication Loss of Indication ALTERNATE INDICATION/

EQUIPMENT AVAILABLE lPRl Operation Available Manual Htr. Control Available on Cont. Console None Loops 11 + 13 Indication Available in Cont. Room CH's I + II Indication Available on Cont. Console None Alternate Press Ind. Available on Cont. Console Diff. Temp. Indication Available for Loops 11, 12, 14 11 RHR Loop Flow Indications Available in Cont. Room Alternate 12 RHR Inj. Flow Ind. Available on Cont.

Console Alternate Indication Available on Control Console DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None None None None

SYSTEM Safety Injection (Cont)

Service Water*

Steam Generator COMPONENT

  1. 12 SI Pump Disch. Press.

Disch. Flow XMTRS. + Indicators Pwr Supply

  1. 11 + 12 S.W. HOR Press RCDR Pwr. Supply
  1. 11 SW HOR Press XMTR

+ Indicator Pwr Supply (Unit 1 Only)

  1. 22 SW HOR Press. XMTR +

Indicator Pwr. Supply (Unit 2 Only)

  1. 's 11, 12, 13, 14 SG's CH. I I I Steam Flow F.W. Flow Press.

Level XMTRS + Indicators Power Supply (Not All Parameters For All S.G.'s on CH.

III) lC VIB EFFECT OF FAILURE Loss of Indication No Sys. Malfunction Due to ck t. Loss Pump Control Available Loss of Recorder on lRPl Loss of #11 SW HOR.

Press. Ind.

  1. 's 11, 12, 13 SW Pumps Auto Control not Affected by Ckt.

Loss Loss of All #22 SW HOR Press. Ind.

  1. 's 24,25,26 SW Pumps Auto Control Not Affected by Ckt. Loss Loss of CH. III Indications (Where Applicable)
  1. 's 11, 12, 13, 14 S.G.'s Loss of W.R. Lvl. Indication W.R. Lvl. XMTRS. Pwr.

Supply ALTERNATE INDICATION/

EQUIPMENT AVAILABLE Start-Stop, Motor Amps Indication Available on Cont.

Console.

  1. 11 SI Pump Available
  1. 12 s.w. HOR. Press. Ind.

Available

  1. 12 SW HOR. Press. Ind.

Available

  1. 21 SW HOR Press. Ind.

Available Alternate Indications Available on CH's I, II, or IV Narrow Range Lvl. Ind.

Available on Cont. Console DESIGN MODIFICATION TO BE EVALUATED None None None None None Pending resolution of design for long term TMI item review

  • Due to the loss of this bus, SEC Train C is lost.

Therefore, no ESF Train C equipment will automatically start/shift modes of operation (if required).

Adequate redundancy is provided for all systems affected (SEC Train A and SEC Train B functional).

Manual control for all affected equipment is available.

M PBO 60 01 23/24

SYSTEM Component Cooling Containment Ventilation Chemical and Volume Control M PBO 60 01 25/26 COMPONENT c.c. Surge Tk. B Lvl.

XMTR. + Indicator Pwr. Supply Cont. Press. CH. IV XMTR + Indicator Pwr.

Supply

  1. 's 14 + 15 Fan Coil Uni ts Leak Detection XMTRS. Pwr. Supply
  1. 13 Chg. Pump Speed +

Flow Control Ckt.

Chg. Sys. Seal. Press XMTR. + Indicator Pwr.

Supply Chg. Line Seal Press.

Control Valve 1CV71 Chg. Flow XMTR. + Flow Control Valve 1CV55 Letdown Isolation Va's.

1CV2, 1CV3, 1CV4, 1CV5 Control Letdown from RHX's Flow Control Valve lCVB" lD VIB EFFECT OF FAILURE Loss of Indication in Cont.

Room Loss of CH. IV Indication Loss of F.C. Unit Leak Detection Indication.

No System Malfunction Due to Ck t. Loss.

Loss of Pump Speed Control.

Pump Remains at Last Speed.

Loss of Chg Seal Press.

Indication Loss of Remote Manual Control of 1CV7 l.

Valve Remains in Last Position.

Loss of Chg Flow Indication Loss of Remote Man + Auto Control 1CV55 Valve Remains in Last Position.

Valves Fail Closed.

Loss of Normal Letdown Flowpath.

Loss of Letdown Capability from RHX's.

Valve Remains in Last Position Valve Normally Closed ALTERNATE INDICATION/

EQUIPMENT AVAILABLE A

CC Surge Tk.

+

Indication Available CH's I, II, III Indication Available on Cont. Console

  1. 's 11, 12, 13 F.C. Units+

Leak Detection Indication Available

  1. 's 11 + 12 Centrifugal Chg.

Pumps Available None None None Excess Letdown Flowpath Available.

Excess Letdown Flowpath Available DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None None

SYSTEM Chemical and Volume Control (Cont)

Main Steam Pressurizer M P80 60 01 27/28 COMPONENT Rapid Borate Flow XMTR. +

Indicator Pwr. Supply

  1. 12 B.A. Tk. Lvl. + Temp.

XMTRS + Ind. Pwr. Supply, Recirc Flow Cont. Va l2CV160 Control BIT B-U Strip Htr Cont.

Ckt. + Temp. XMTR.

Steam Dump Train B Control Ckt.

CH. 1 First Stage Turbine Press XMTR., Tref + S.G.

Lvl.Setpoint Cont. Ckt.

Atmos. Steam Relief Valves llMSlO + 14MS10 Control Atmos. Steam Relief Valves llMSlO, 13MS10, 14MS10 Setpoint + Demand Indicators Power Supply PRZ. Lvl. Control XMTR. Pwr. Supply PRZ. Lvl. Cold Cal.

XMTR. + Indicator Pwr.

Supply PRZ. Surge Line Temp. +

Loops 11, 13 Safety Valve Disch. Temp., XMTRS. +

Indicators, Loop 12 Indicator Pwr. Supply PRZ. Relief Valve 1PR2 Disch. Temp. XMTR. +

Indicator Pwr. Supply +

1PR2 Auto Control (High Press) lD VIB '

EFFECT OF FAILURE I I

Loss of Rapid Borate Flow Indication I

Loss of all Indication for

  1. 12 B.A. Tk.

Loss of Control 12CV160 Valve Remains in Last Pos.

Loss of BIT Temp Ind.

Loss of BIT B-U Htrs.

Loss of Train B Steam Dump Capability Loss of Thermal Pwr Tref for Rod Control Loss of Tref. for Steam Dump Loss of Auto or Manual Control Loss of Indication Pwr. Loss Causes Er'roneous Lo-lo Lvl. Signal Which Automatically Trips the PRZ Htr.

Control + B-U Groups Loss of PRZ. Lvl. Cold Cal.

Indication in Cont. Room.

Loss of Surge Line Temp. +

Safety Valve Disch. Temp.

All Loops Indication in Cont. Room.

Loss of Temp. Ind. for 1PR2 Loss of Operation 1PR2 ALTERNATE INDICATION/

EQUIPMENT AVAILABLE None

  1. 11 B.A. Tk. + Recirc Control Available Normal Strip Htr. Control Available Steam Dump Train A Available CH. II First Stage Pre~s Indication + Functions Available Tavg. Steam Dump Mode Remains Available Atmos.

Steam Relief Valves (12MS10 + 13MS10) Available 12MS10 + 13MS10 Local + Remote Control Available.

Local Control llMSlO + 14MS10 Available.

Steam Dump Available.

Safety Valves Operable.

S.G.'s Press. Indication Available None None None lPRl + all Indication Available in Cont. Room DESIGN MODIFICATION TO BE EVALUATED None None None None None None None None None None None

SYSTEM Reactor Coolant Residual Heat Removal Rod Control Safety Injection M PBO 60 01 29/30 lD VIB COMPONENT EFFECT OF FAILURE

  1. 14 R.C. Loop Loss of all Loop 14 Temp.

Diff. Temp.

Information Diff. Temp. Setpoints XMTRS. + Indicators W.R. Hot Leg Temp.

W.R. Cold Leg Temp.

Indicators Pwr. Supply RHX's Bypass Control Loss of Manual Valve Control Valve 1RH20 Valve Remains in Last Position.

Valve Normally Closed Bank Control Rod Position Loss of Recorders Recorders Pwr. Supply T Auct. Rod Control RWST Lvl. XMTR. +

Indicator Pwr. Supply

  1. 's 13 + 14 Accumulators Level + Press. XMTRS. +

Indicators Pwr. Supply

  1. 11 SI Pump Disch.

Press. + Flow XMTRS. +

Indicators Power Supply Loss of all Inputs to Rod Control and Rod Speed

  • Control.

Loss of Auto-Man. Bank Selector Switch Operation.

Rod Control Urgent Failure Alarm in Cont. Room Rods Remain in Last Position Loss of RWST Level Indication Loss of Level + Press.

Indications Loss of Loops 11 + 14 SI Flow

+ Press. Indication ALTERNATE INDICATION/

EQUIPMENT AVAILABLE None RHR Loops Flow Indication Available Rod Position Indication, Available on Cont. Console.

Rod Bottom Lights Operational.

Reactor Trip Capability Remains Operational Alternate RWST Level Indication Available on Cont.

Console Alternate Level + Press Indications Available on Control Console.

  1. 12 SI Pump Disch. Press. +

Disch. Flow Ind. Available on Cont. Console DESIGN MODIFICATION TO BE EVALUATED None None None None None None None

SYSTEM Steam Generator M P80 60 01 31/32 lD VIB COMPONENT EFFECT OF FAILURE l's 11, 12, 13, 14 S.G.'s Loss of CU. IV Indications CH. IV (Where Applicable)

Steam Flow F.W. Flow Press Level XMTRS. + Indicators Power Supply (Not All Parameters For All S.G. 's on CH. IV)

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE Alternate Indications for all Parameters Available on CH's I, II, or III DESIGN MODIFICATION TO BE EVALUATED None

__J

SYSTEM Auxiliary Feedwater Component Cooling Chemical and Volume Control M P80 58 04 1/2 COMPONENT

  1. 11 AFW Pump Suet. Press.

Disch. Press.

Motor Amps.

Indicators Power Supply

  1. 13 & 14 S.G.'s AFW Flow Indicators Power Supply AFW S.G. Inlet Valves (13AF21, 14AF21)

Indicator Power Supply

  1. 13 AFW Pump Pump Speed Speed Demand Suet. Press.

Alt. Suet. Press.

Disch. Press.

Steam Press.

Indicators Power Supply AFW Storage Tank Level Indicator Power Supply

  1. 11, 12, & 13 CCP's Motor Amps Indicators Power Supply LTDN Temp. Cont.

VA. 1CC71 Pos. Ind. Ckt.

8.A. Flow Control VA.

1CV172 and Primary Water Flow Control VA. Position Indicating Circuits.

Primary Water Storage Tank Level Indicator Power Supply 11 MAC PANEL EFFECT OF FAILURE Only pump start-stop indication remains.

Loss of indication only.

Cannot determine if pump is cavitating.

Pump operation not affected by ckt. loss.

Loss of indication only.

No system malfunction due to ckt. loss.

Loss of indication only.

No system malfunction due to ckt. loss.

Loss of all Control Room indi-cation pertaining to #13 AFW pump.

No system malfunction due to ckt. loss.

If pump required to operate, local operation necessary.

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE Local indication available.

  1. 12 AFW pump indication and operation available.

S.G. level indication available.

S.G. level indication available.

Local indication available.

Refer to S.G. level indica-tor's to determine adequate delivery.

Loss of AFW storage tank level Local indication available.

indication.

Loss of indication only.

Loss of pos. indication only, no valve operation due to failure.

Loss of voltage results in opening of valve position mult. relay contacts causing:

Loss of Supply from 8.A.

Blender to Chg. Pumps.

Loss of M-U to VCT from 8.A.

Blender.

Loss of M-U to B.A. Blender from Primary Water Storage Tank.

Loss of Auto Start for 11 & 12 Primary Water M-U Pumps.

Loss of indication only.

Start-stop indication avail-able.

Alarms available.

Hi-temp alarm operable.

Must take manual control of Primary Water M-U Pumps.

Local indication available.

DESIGN MODIFICATION TO BE EVALUATED Change Power Supply for Suet.

and Disch. Press Indicators to lA VIB.

Change Power Supply to lA VIB.

Change Power Supply to lA VIS.

Change Power Supply to lC VIS.

Change Power Supply to lA VIS.

None.

None.

None.

None.

None.

SYSTEM Condensate Containment Spray Control Air Diesel Generators Main Steam Pressurizer Reactor Coolant M PBO 58 04 3/4 COMPONENT Boric Acid Flow Register and Primary Water Flow Register Power Supply

  1. 's 11, 12, and 13 Cond.

Hotwell Level Indicators, Abs. Press Indicators, M-U Flow Recorder, Vacuum

_Recorder Power Supply

  1. 's 11 and 12 Motor Amps Indicators Power Supply lA & lB Hdr. Press.

Transmitters and Hdr.

Press. Recorder Power Supply lA and lC D.G. 's Volts Frequency Watts Amps Indicators Power Supply Atmos. Relief VA's 12MS10 and 13MS10 Position Indicating Relays

  1. 's 11 and 12 Spray Control Valves (lPSl & 1PS3) Position Indicating Relays
  1. 's 11 and 13 RCP's Motor Amps Indicators Power Supply 11 MAC PANEL EFFECT OF FAILURE Loss of primary water M-U &

B.A. Flow auto-stop function from registers.

Loss of indication only.

effect on steam dump capability.

No Loss of Control Room indica-tion only, no effect on system opera ti on.

All Control Room information pertaining to control air sys-tem lost.

Operator forced to declare loss of control air accident.

Loss of this ckt.

also causes loss of #1 Emer-gency Control Air, Air Comp.,

air dryer.

Only indication is lost due to this failure.

System will not malfunction.

Loss of all operating para-meters indication.

If neces-sary to operate D.G. 's, local operation possible.

Failure of ckt. does not effect D.G.

availability.

Loss of position indication only, valve control not affected by ckt. loss.

Loss of indication only.

Valve control not affected by ck t. loss.

Loss of indication only.

Pump operation not affected by ck t. loss.

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE Must take manual control of Primary Water M-U pumps, B.A.

flow & Primary Water flow indications available on cont. console.

Condenser vacuum indicating light available on status panel, local indication available.

None.

None.

Can verify operation VIA pump None.

start-stop indication, NaOH additive tank* outflow indica-tion, decreasing tank level indication.

DESIGN MODIFICATION TO BE EVALUATED Local indication available.

lA Hdr. XMTR. and indicator Power Supply to be separated from lB HDR XMTR. and indicator Power Supply to avoid erroneous indicated loss of control air accident.

Local indication available.

Change lA D.G. indicators Power Supply to lA VIB.

Change lC D.G. indicators Power Supply to lC VIB.

Steam generator pressure indi-None.

cation avai~able in Control Room.

Pressurizer pressure indica-None.

tion available in Control Room Pump start-stop indication and None.

loop flow indication available in Control Room.

SYSTEM Residual Heat Removal Rod Control Safety Injection Service Water Station Air Penetration Area Ventilation Containment Ventilation M PBO 58 04 5/6 COMPONENT

  1. 's 11 and 12 RllR Pumps Motor Amps Indicators Power Supply
  1. 11 RHX Outlet Control Valve llRHlB Position Indicating Relays Control & Shutdown Rod Position Indicators Power Supply
  1. 's 11 and 12 SI Motors Amps Indicators Power Supply
  1. 's 11, 12, 15, and 16 Pumps Motor Amps Indicators Power Supply
  1. 1 Station Air Comp.

Control Ckt.

(Unit U Only)

  1. 2 Station Air Comp.

Control Ckt.

(Unit 2 Only)

Inlet and Exhaust Dampers lCAVB 1CAV9 lCAV 12 lCAV13

  1. 's 11, 13 and 15 Fan Coil Units Outlet Water Temp. and Flow indicators Power Supply 11 MAC PANEL EFFECT OF FAILURE Loss of indication only, syst-em operation not affected by ckt. loss.

Loss of Open-Close position indication.

Loss of indication only.

All indicators fail mid-scale.

Ckt. loss has no effect on rod control circuitry.

Loss of indication only.

Ckt. loss has no effect on system operation.

Loss of indication only.

Ckt loss has no effect on system operation.

Loss of #1 Station Air Com-pressor (if running).

Loss of #2 Station Air Com-pressor (if running).

ALTERNATE INDICA'rION/

EQUIPMENT AVAILABLE Pump operation may be verified via disch. press. indication in Control Room.

  1. 12 RHR loop available.

None.

None.

Step counters, position & in-None.

sertion limits recorder avail-able on Control Console.

Core flux indication available in Control Room.

Disch. Press. and Disch. Flow None.

Indication available on Control Console.

  1. 's 11 and 12 Hdr. Press indi-None.

cation available on Control Console.

  1. 2 and #3 Station Air Compres-None.

sors available.

  1. 1 and #3 Station Air Compres-None.

sors available.

DESIGN MODIFICATION TO BE EVALUATED Penetration area may be sub-None.

Design to allow dampers to fail open upon loss of power.

Must be evaluated with respect to fire protection system reqts.

jected to higher temp. causing alarms.

Loss of ckt. and damper closures cause penetra-tion area exhaust fans to turn off.

Loss of indication only.

Ckt. loss has no effect on system operation.

Service water supply remains.

S.W. indication for #'s 12 +

14 F.C. units available on Cont. Console.

None j

SYSTEM Auxiliary Feedwater Chemical and Volume Control Control Air M P80 58 04 7/8 COMPONENT

  1. 12 AFW Pump Suet. Press.

Discharge Press.

Motor Amps.

Indicators Power Supply

  1. 11 and 12 S.G.'s AFW Flow Indicators Power Supply AFW S.G. Inlet Valves (11AF21, 12AF21)

Indicators Power Supply Aux. Feed Pumps Suction Press. Indicator Power Supply

  1. 's 11 and 12 Chg. Pumps Motor Amps. Indicators Power Supply Chg. Seal Press. Cont.

VA. 1CV71 Pos. Indicating Relays and Chg. Flow Cont. VA. 1CV55 Position Indicating Relays Letdown Press. Cont.

VA. 1CV18 Pos. Indicating Relays Letdown Flow Cont.

VA. 1CV8 (from RHX's)

Pos. Indicating Relays i's 11 and 12 B.A. Tank's Recirc. Valves 11CV160 &

12CV160 Pos. Ind. Relays lA and lB HDR. Press.

Indicators Power Supply 12 MAC PANEL EFFECT OF FAILURE ALTERNATE INDICATION/

EQUIPMENT AVAILABLE DESIGN MODIFICATION TO BE EVALUATED Only pump start-stop indica-tion remains.

Loss of indica-tion only.

Cannot determine if pump is cavitating.

Pump operation not aEfected by Local indication available.

  1. 11 and 13 AFW pumps indica-tion and operation available.

Change Power Supply for Suet.

and Disch. Press. Indicators to lB VIB.

ckt. loss.

Loss of indication only.

No system malfunction due to ckt. loss.

Loss of indication only.

No system malfunction due to ckt. loss.

Loss of indication only.

No system malfunction due to ck t. loss.

Loss of motor amps indication only.

Start-stop indication and control still available in Control Room.

S.G. level indication available.

S.G. l~vel indication available.

Individual AFW pump suet.

press. indication available except #12 AFW pump suet.

press. indication as noted above.

Change Power Supply to lB vrn.

Change Power Supply to lB VIB.

None.

Chg. flow indication available None.

to verify operation.

Loss of pos. ind. only.

control remains.

Valve Chg. system seal press. and None.

Loss of pos. ind. only.

control remains.

Loss of pos. ind. only.

control remains.

Loss of pos. ind. only.

control remains.

flow indication available on Control Console.

Valve Letdown press. ind. available None.

on Control Console.

Hi-press. alarm remains operable.

Valve Letdown from RHX demand indi-None.

cation available on Control Console.

Valve B.A. Recirc. demand indication None.

available on Control Console.

Loss of indication only.

of ckt. has no effect on system operation.

Loss lA and lB Control Air Hdr.

Press. RCDR on lRPl operable.

None.

SYSTEM Diesel Generator Main Steam Pressurizer Reactor Coolant Residual Heat Removal Rod Control Service Water Station Air M P80 58 04 9/10 COMPONENT lB Diesel Generator Volts Frequency Watts Amps Indicators Power Supply Atmos. Relief VA's llMSlO and 14 MSlO Position Indicating Relays Control Heaters A,

B, c Amps.

Indicators Power Supply

  1. 's 11, 12, 13, 14 R.C.

Loops Hot & Cold Legs Temp.

Indicators Power Supply RHX's By-Pass Valve 1RH20 Position Indicating Relays

  1. 12 RHX Outlet Cont.

VA. 12 RH18 Position Indicating Relays Rod Bottom Lights

  1. 's 13 and 14 SW Pumps Motor Amps.

Indicators Power Supply

  1. 3 Station Air Comp.

Control Ckt.

(Unit l Only) 12 MAC PANEL EFFECT OF FAILURE Loss of all lB D.G. operating parameters ind. If necessary to operate, local operation a necessity.

Failure of ckt.

does not affect D.G.

availability.

Loss of pos. ind. only.

Valve control not affected by ckt.

loss.

Loss of Amps. Ind. only.

Heater control not affected by ckt. loss.

Loss of temp. ind. Information necessary as part of SI termi-nation criteria for MSLB.

Loss of pos. ind. only.

Valve control remains.

Valve does not change position when ckt.

lost.

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE Local indication available.

Control Room indication avail-able for lA and lC D.G.'s.

Steam Generator pressure indi-cation available on Control Console.

Prz. level and press. ind.

available on Control Console.

Avg. temp. ind. and&>. T ind.

for all loops available on Control Console.

  1. 's 11 + 12 RHR loops flow ind. and control valves operation available.

DESIGN MODIFICATION TO BE EVALUATED Change Indicators Power Supply to lB VIB.

None.

None.

Change 11 RC loop ind. Power Supply to lA VIB.

Change 12 RC loop indicator Power Supply to lB VIB.

Change 13 RC loop. ind. Power Supply to lC VIB.

Change 14 RC loop ind. Power Supply to lD VIB.

None.

Loss of pos. ind. only.

Valve

  1. 11 RHR loop available.

control not affected by ckt.

None.

lost.

Loss of rod bottom lights.

Loss of indication only.

Ckt. loss has no effect on system operation.

Loss of #3 Station Air Com-pressor (if running).

Rod position indicators, step None.

counters, position and inser-tion limits RCDR available in Control Room.

  1. 's 11 and 12 Hdr. press. ind.

None.

available on cont. console.

  1. 's 1 and 2 Station Air Com-None.

pressors available.

SYSTEM Station Air (Cont'd)

Station Communications Steam Generator Containment Ventilation M P80 58 04 11/12 COMPONENT

  1. 1 Station Air Compressor Motor Amps.

Indicator Power Supply (Unit 1 Only)

A and B Station Air Hdrs.

Press. Indicators Power Supply Power Supply to station P.A. System Cabinets

  1. 's 11, 12, 13, 14 S.G.

Wide Range Level Recorders Power Supply

  1. 's 12 and 14 Fan CoilUnits Outlet Water Temp. and Flow Indicators Power Supply 12 MAC PANEL EFFECT OF FAILURE Loss of motor amps. indication only.

Ckt. loss has no effect on compressor availability.

Loss of press. ind. only.

Ckt. loss has no effect on system availability.

P.A. system rendered inoperable.

Loss of all wide range level indication in Control Room.

Loss of indication only.

Ckt.loss has no effect on system operation.

Service water supply remains.

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE All remaining compressor indi-cation and alarms operable.

Alarms and valve position indications available.

Narrow range level indication available on Control Console.

S.W. indication for #'s 11, 13, 15 F.C. units available on cont. console.

None.

None.

DESIGN MODIFICATION TO BE EVALUATED A back-up power supply and capability to quickly transfer the system.

Pending resolution of design for long-term TMI item review.

None.

SYSTEM Condensate Control Air Station Air M PBO 58 04 13/14 COMPONENT Condenser Abs. Press. XMTR.

Vacuum XMTR.

Hotwell Level XMTRS.

Power Supply t's 11 and 12 Control Air Dryers Service Water By-Pass Valves (11SW49 and 12SW49) Alarm Relays (Unit l Only)

A and B Hdr. Press.

Transmitters 13 MAC PANEL EFFECT OF FAILURE Loss of all Control Room indication pertaining to condenser.

Steam Dump capability not affected by ckt. loss.

All solenoids fail closed causing loss of #'s 11 and 12 control air dryers.

ALTERNATE INDICATION/

EQUIPMENT AVAILABLE Local ind. available.

  1. 's 13 and 14 control air dryers operational.

Loss of OHA alarm window which None.

notifies operator of valve operation.

If valve opens fully the amount of water bypassed is equivalent to the flow of one S.W. pump.

The amount bypassed is not significant enough to cause problems in equipment supplied by the S.W. system.

Ckt. Loss also causes loss of by-pass elapsed time indicators on recorder p_anel lRPl.

Loss of hdrs. press. ind.

only.

System availability not affected by ckt. loss.

Local indication available.

System low press. alarms functional.

None.

None.

None.

None.

DESIGN MODIFICATION TO BE EVALUATED

SYSTEM Station Air M P80 58 04 15/16 COMPONENT

  1. 2 Emergency Comp.

Air Dryer Solenoids (Unit l Only) 14 MAC PANEL EFFECT OF FAILURE Loss of #2 Emergency Comp.

ALTERNATE INDICATION/

DESIGN MODIFICATION EQUIPMENT AVAILABLE TO BE EVALUATED Normal station air compressors None.

available.

I 2-02 PUBLIC SERVICE ELECTRIC AND GAS COMPANY ENGINEERING AND CONSTRUCTION DEPARTMENT ATTACHMENT B DATE:

April 26, 1979 RESPONSE DUE:

TO:

E. N. Schwalje Manager - Quality Assurance FROM:

F. A. Christiana Chief Controls Engineer

SUBJECT:

SALEM NUCLEAR GENERATING STATION UNITS NO. 1 AND 2 RESPONSE TO IE CIRCULAR NO. 79-02 DESIGN FEATURES OF UNINTERRUPTAELE 120 VOLT VITAL AC POWER SOURCES The design of the Salem 120 volt uninterruptable power supplies has been examined in the perspective of problems experienced witt Ar~aL sas Nuclear One -

Unit 2.

The initiating event was a degradation of both independent offsite power sources.

This would cause the DC link tc be powered from the batteries, which is sirrilar to the Salem design.

The four questions which the circular recommends be reviewed are answered below with a brief perspective provided.

l.

Determine whether er not time delay circuitry is us-::d 'in your inverter units.

If so, have th-::y been adjusted to the appropriate set point as required by* equipment and the in-tegrated system designs?

The description of circumstances notes that the Arkansas Kuclear 1 -

Unit 2 design provides for a low DC link voltage to trip both input breakers (Battery and AC to power supply), after an adjustable time delay, and that the settings had not been verified.

The Garrett inverter does not provide circuitry of any form to trip the DC or AC input breakers.

Therefore, there are no adjustments to be verified.

The description further notes that the purpose of the adjustable time delay is to permit the battery to recover from transient demands which might cause the battery voltage to fall below 104VDC.

_The Salem 125VDC battery supply system is designed to pre-clude the battery being subjected to such a severe transient.

This is essential to system design as the inverter is not designed to operate below 105VDC.

(

(

N. Schwalje

- :? -

4/2(__/79

~.

Determine if the AC input voltage and transformer tap set~in~s are optimiz~d tc prevent exc~eding the inverter co~pcnent Da~e plate maximum rated DC input voltage in the event of a tigt 3.

AC input voltage transi8nt.

The description of circumstances nctes that a DC fuse wit~~n one inverter was blown and the failure attributed ts an i~duc tive input transient caused when a static switch transferred.

It is further noted that the static switch is designed tc transfer to an alternate source on inverter output cvercurrent or undervoltage.

The Garrett Inverter Power Sunnly is ccn-servatively designed to absorb input transients without ca~sin misoneration.

Garrett and PSE&G experience with this in~er~er design typically shows fuse failure to be caused by tte si~~l taneous firing of two opposing thyristers, generally 6aused by logic circuit malfunction..

PSE&G is planning tc reduce input voltage to the inverter power supply in crder tc reduce DC link voltage, but this will be primarily to reduce steady state stress on inverter components, for increased reliabiiity.

If an alternate 120 volt source is used in ycur desig~,

determine if the protection transfer circuitry cf the inverter has been optimized within design limits to ensure maximu~

possible availability of the inverter system during transient loading conditions.

An cperating history of inexplicable transfers may be indicative of the abcve.

The discussion notes that the SCI inverter prcvides* a one-¥ay transfer on inverter output undervcltage er overcurrent, and that this circuit is adjustable; The Garrett circuit provides for automatic transfer in both directions.

The transfer ncint is established by circuitry which is essentialiy net ad~ustatle.

The load is transferred from alternate scutce tc inverter ~~en inverter output voltage is present.

The load nor~ally ~il~ be transferred back to the alternate source when inverter c~~p~t is lost.

However, if output current is high, indicatin£ &

possible short circuit, transfer is blocked.

The transfer points are not presently subject tr verificctior..

The inverter is designed tc run from 109 -

125VA~, and is lightly loaded (significantly less than 100% current).

There-fore, the transfer circuitry has been "optimized" for maxi:mur..

reliability.

The NRC has required the circuit breaker for the alternate 120 VAC source to be administratively open.

Any transfer would be to a dead bus.

I E. 4/2t/79

4.

Determine if the administrative controls employed by yo~r facility ensures operability of safety systems after its subcomponents (e.g., time delay relays, switches, etc.) have been subjected to maintenancP or testing.

Voltage readings on the DC link and AC output volta£e ans current periodically recorded.

The exact transfer pcint s~

the transfer circuitry is not measured.

No time delays are used.

~~fr)!

F. X Oittsttanc:

2"J~:sab