UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA 19406 Docket Nos. 50-354 50-355 50-311 FEB O 8 1980 Public Service Electric and Gas Company ATTN.
Mr. T. J. Martin
- . Vice President
, Engineering and Construction 80 Park Place Newark, New*Jersey 07101 Gentlemen:
The enclosed IE Information Notice is forwarded to you for information.. No written response to this Information Notice is required.
If you have any questions related to the subject, please contact this office.
Sincerely,
~}'}/,~
~ Boyce H. Grier f.-- Di rector
Enclosures:
- 1.
IE Information Notice No.
80~05
- 2.
List of Recently Issued IE Information Notices CONTACT:
L. E. Tripp (215..;337-5282) cc w/encls:
E. N. Schwalje, Manager - Quality Assurance, Engineering and Construction Department If~
8002250 l b6 ff)
. ENCLOSURE 1 UNITED STATES.
NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 SSINS No.:
6870 Accession No.:
7912190673 IE. information Notice No. 80-05 Date:
February 8, 1980 Page 1 of 1 CHLORIDE CONTAMINATION OF SAFETY RELATED PIPING AND COMPONENTS A Bechtel Power Corporation Study at the Wolf Creek Project has revealed that a fire retardant coating is potentially corrosive in contact with stainless steel.
- Albi 11Duraspray 11 is a fire retardant coating which contains magnesium oxychloride, and is used for fireproofing of exposed structural steel in some Nuclear Power Plants. There appears to be no deleterious effect when it is applied over unprimed, inorganic zinc coated, or galvanized steel, however, it may be corrosive in contact with stainless steel, bare aluminum or copper.
Droppings or overspray of this material cannot be properly removed with water.
Diluted Nitric acid has been proven to be a useful cleanser, however, it presents a safety hazard.
Applicants and holdeh of construction permits and licensees of operating power reactors are advised to protect all stainless steel, copper and aluminum material from overspray and droppage of cementitious oxychloride materials and to remove accidently applied materials immediately and completely employing strict safety precautions during the process.
Special attention should be given to weld areas in any removal procedures.
No written response to this information notice is required. If you require additional information regarding this matter* contact the Director of the appropriate NRC Regional Office.
Information Notice No. 79-29 79-30 79-31
}9-32 79-33 79-34 79-35*
79-36.
79-37 80-01.
80-02 80-03 80-04 ENCLOSURE 2 IE Information Notice No. 80-05 Date:
- February 8, 1980 Page 1 of 1 RECENTLY ISSUED IE INFORMATION NOTICES Subject Date Issued to Issued Loss of Nonsafety Related 11/19/79 All Power Reactor Faci-Reactor Coolant System In-lities with an Operating strumentation During Operation License (OL) or Construction Permit (CP)
Reporting of Defects and 12/6/79 All Power Reactor Faci-
- Noncomp 1 i arices, 10 CFR lities with an OL Part*21 or CP Use of incorrect Amplified 12/13/79 All Power Reactor Faci-Response Spectra (ARS) lities with an OL or CP Separation of Electrical 12/21/79 All Power Reactor Faci~
Cables for HPCI and ADS litie~ with an OL or CP Improper Closure of Primary 12/21/79 All Power Reactor Faci-Containment Access Hatches lities with an OL or CP Inadequate Design of Safety-12/31/79 A 11 Power Reactor F aci -
Related Heat Exchangers lities with an OL or CP Control of Maintenance 12/31/79 All Power Reactor Faci-
- and Essential Equipment lities with an OL or CP Computer Code Defect in 12/31/79 A 11 Power Reactor Faci-Stress Analysis of Piping lities with an OL or CP Elbow Cracking in Low Presssure 12/31/79 All Power Reactor Faci-Turbine Discs lities with an OL or CP Fuel Handling Events 1/4/80 All Power Reactor Faci-lities with an OL or CP 8X8R Water Rod Lower 1/25/80 All BWR Facilities with