Approves 780110 Rept Re Provisions Made for Minimizing Water Hammer Events Due to Rapid Condensation of Steam in Feedwater Sys.Safety Evaluation Encl
ML18081A614
Person / Time
Site: Salem PSEG icon.png
Issue date: 11/03/1979
From: Schwencer A
Office of Nuclear Reactor Regulation
To: Librizzi F
Public Service Enterprise Group
Shared Package
ML18081A615 List:
References
NUDOCS 7911280221
Download: ML18081A614 (3)


Text

DISTRIBUTION:

Docket NRC PDR NOVEMBER

'J,

  • 1979 Docket No. 50-272 Local PDR ORB-1 Reading NRR Reading DEisenhut WPGammill BGrimes GLainas ASchwencer WRoss Mr. F. P. Librizzi General Manager - Electric Production Public Service Electric and Gas Company 80 Park Place Newark, Hew Jersey 07101

Dear Mr. Librizzi:

KParrish Attorney, OELD I&E (3)

ACRS (16)

TERA JRBuchanan As part of our generic rcv"iew of secondary system fluid flow instabilities at nuclear power plants, we have reviewed your submittal of January 10, 1978 for the* Salem Nuclear Generating Station Unit 1.

He find that the provisions which you have made for minimizing the likelihood of water hammer events due to the rapid condensation of steam in the feedwater systems at Salem Unit l are acceptable. Enclosed is a NRC Safety Evaluation Report which deals with all aspects of water hammer problem.

Enclosure:

Safety Evaluation Report cc w/enclosure:

See next page

  • Sincerely,

<Jrigihal Signed SYJ A. Schwencer, Chief

. Operating Reactors Branch #1 Division of Operating Reactors

' (.'

JJi;**.:

/1J*..

  • \\

Ol'FICl!l:~

\\.\\

. O.O.R;.~_;:19*****.. 0.0.R;.OJ~.~.-:-

/,~!;)

,, 'r~
  • URNAMIE~

J~.RQ.$.$.;.~$\\....... A~~hw~n(:; r................................................................................. -.........................

).!!fl.!?.~.............................................. ;..............................................................

DATE~

"k u.s. oov1rnNM1tNT PRINTING> Ol"FICII: 1071 -.:p..

7 911 2 8 0 2. 1 ;~';

  • e UNITED ST ATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 November 3, 1979

. Docket No. 50-272 Mr. F. P. Librizzi General Manager - Electric Production Public Service Electric and Gas Company 80 Park Place Newark, New Jersey 07101

Dear Mr. Librizzi:

As part of our generic review of secondary system fluid flow instabilities at nuclear power plants, we have reviewed your submittal of January 10,

~978 for the Salem Nuclear Generating Station Unit 1.

We find that the provisions which you have made for minimizing the likelihood of water hannner events due to the rapid condensation of steam in the feedwater systems at Salem Unit 1 are acceptable.

Enclosed is a NRC Safety Evaluation Report which deals with all aspects ~f water hannner problem.

Enclosure:

Safety Evaluation Report cc w/enclosure:

See next page dn~{i.!d/(-'t-/

A. Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors

. j

  • e Mr. F. P. Librizzi Public Service* Electric and Gas Company cc:

Mark J. Wetterhahn, Esquire Conner, Moore and Corber Suite 1050 1747 Pennsylvania Avenue, NW Washington, D. c.

20006 Richard Fryling, Jr., Esquire

  • Assistant General Solicitor Public Service Electric and Gas Company 80 Park Pl ace
  • Newark, New Jersey 07101 Gene Fisher, Bureau of Chief Bureau of Radiation Protection 380. Scotch Road
  • Trenton, New Jersey 08628 Mr. Hank Midura, Manager Salem Nuclear Generating Station Public Service Electric and Gas Company 80 Park Place Newark, New Jersey--Q/101 Mr. R. L. Mittl, General Manager Licensing and Environment Public Service Electric and Gas Company 80 Park Place Newark, New Jersey 07101 Salem Free Library 112 West Broadway Salem, New Jersey 08079 Leif J. Norrholm U *. S. Nuclear Regulatory Commfssion Drawer I Hancocks Bridge, New Jersey 08038 November 3, 1979.