ML18079B005

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 50-272/79-14 on 790416-20 & 0522-25.No Noncompliance Noted
ML18079B005
Person / Time
Site: Salem PSEG icon.png
Issue date: 08/09/1979
From: Robert Carlson
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Schneider F
Public Service Enterprise Group
Shared Package
ML18079B006 List:
References
NUDOCS 7910010392
Download: ML18079B005 (2)


See also: IR 05000272/1979014

Text

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION I

631 PARK AVENUE

KING OF PRUSSIA, PENNSYLVANIA 19406

Docket No. 50-272

JIUE 0 9 1979

Public Service Electric and Gas Company

ATTN:

Mr. F. W. Schneider

Vice President - Production

80 Park Place

Newark, New Jersey 07101

Gentlemen:

Subject:

Inspection 50-272/79-14

This refers .to the inspection conducted by Mr. R. A. McBrearty of this office on

April 16-20, 1979 and May 22-25, 1979~ at Hancocks Bridge, New Jersey, of activi-

ties authorized by NRC License No. DPR-70 and to the discussions of our findings

held by Mr. McBrearty with Mr. H. Midura of your staff' at the conclusion of the

inspection, and to a subsequent telephone discussion between Messrs. L. Lake and

B. Leaf of your staff and Mr. McBrearty on June 11, 1979 and July 2, 1979 .

Areas examined during this inspection are described in the Office* of Inspection

and Enforcement Inspection Report which is enclosed with this letter. Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observations by the

inspector.

Within the scope of this inspection, no items of noncompliance were observed.

In accordance with Section 2.790 of the NRC's

11Rules of Practice,

11 Part 2, Title

10, Code of Federal Regulations, a copy of this letter and the enclosures will

be placed in the NRC

1 s Public Document Room.

If this report contains any infor-

mation that you (or your contractorl believe to be proprietary, it is necessary

that you make a written application within 20 days to this office* to withhold

such information from public disclosure. Any* such application must be accompanied

by an affidavit executed by the owner of the information, which identifies the

document or part sought to be withheld; and which contains a statement of reasons

which addresses with specificity the items which will be considered by the

Commission as listed in subparagraph (bl (_4} of Section 2.790.

The information

sought to be withheld shall b~ incorporated as far as possible into a separate

part of the affidavit.

If we do not hear from you in this regard*within the

specified period, the report will be placed in the Public OOcument Room.

I

Public Service Electric and Gas

Company

2

No reply to this letter is required; however, should you have any questions

concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

!JI J!V, iJi/ku~

f

Robert T. Carlson,lehief

Reactor Construction and

Support Branch

Enclosure:

Office of Inspection and Enforcement Inspection

Report Number 50-272/79-14

cc w/encl:

F. P. Librizzi, General Manager - Electric Production

E. N. Schwalje, Manager.;. q*uality Assurance

R. L. Mittl, Gener~l Manager - Licensing and Environment

H. J. Midura, Man.ager - Salem Generatfog Station

Engineering