ML18079A878

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-14,Suppl 1, Seismic Analysis for As-Built Safety-Related Piping Sys. Action Required
ML18079A878
Person / Time
Site: Salem PSEG icon.png
Issue date: 08/15/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Schneider F
Public Service Enterprise Group
References
NUDOCS 7908300187
Download: ML18079A878 (1)


Text

.

-- ~p.R REGu c,'-

("I

{¥-.~~}

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 0

~

~,,,

631 PARK AVENUE

i.-?

~o KING OF PRUSSIA, PENNSYLVANIA 19406

        • ~

Docket No. 50-272 AUG 1 5 1979 Public Service. Electric and Gas Company ATTN':

Mr. F. W. Schneider Vice President - Production 80 Park Place Newark, New Jersey 07101 Gentlemen:

The enclosed supplement to Bulletin 79-14 is forwarded to you to provide added guidance on the intent of the Bulletin. If you desire additional infbrmation regarding this matter, please contact this office.

Sincerely, *

' l!iM.~

.,J,,n/Boyce H. Grier

'fv"" Director

Enclosures:

1.

Supplement IE Bulletin 79-14

2.

Listing of IE Bulletins Issued in the Last 6 Months cc w/encls:

F. P. Librizzi, General Manager - Electric Production E. N. Schwalje, Manager - Quality Assurance R. L. Mittl, General Manager - Licensing and Environment H. J. ~idura, Manager - Salem Generating Station 79083 00(~7