Startup Test Program Description Salem Unit 1 Cycle 2 Test Power Coefficient Initial Conditions:

Reactor power is not changing.

The Xenon concentration is within 3% of its equilibrium value.

This test is run twice during the startup program.

First at 50% power, then at 100%.

Test

Description:

Take a heat balance.

Change turbine power be-tween 2% and 4% with the control rods in manual.

The Tavg andilT recorders will monitor changes in these parameters as a function of time.

Acceptance Criteria:

Design:

Design value ~ 30%

FSAR/T.S.

Must fall between upper and lower curve assumed in FSAR accident analysis.