ML18079A701

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 79-19, Pipe Cracks in Stagnant Borated Water Sys at PWR Plants. No Action Required
ML18079A701
Person / Time
Site: Salem 
Issue date: 07/17/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Schneider F
Public Service Enterprise Group
References
NUDOCS 7908060010
Download: ML18079A701 (1)


Text

e UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA 19406 JUL 17191~

Public Service Electric and Gas Company ATTN:

Mr. F. W. Schneider

  • Vice President - Production 80 Park Place Newark, New Jersey 0710.l

. Gentlemen:*

This Information Notice is provided as an early notification of a possibly significant matter. It is expected that recipients will review the information for possible applicability to their facilities.

No response is requested at th1s time however. licensees should be aware that the NRC is evaluating the issuance of a Bulletin to operating PWR 1s requesting information on previous inservice inspections of stagnant borated water systems and requesting inspection of systems which have not been inspected recently. If you have questions or comments regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Sincerely,*

. g __ ~JI~

~ ~~- Grier

Enclosures:

i~

IE Information Notice No. 79-19

2.

. IE Circ~lar 76-06 Director

3.

Li st of Information Notices Issued in 1979 cc w/encl s:

F. P. Librizzi, General Manager - Electric Production E. N. Schwalje, Manager - Quality Assurance R. L. Mittl, General Manager - Licensing and Environment H. J. Midura, Manager - Salem Generating Station