Monthly Operating Rept for May 1979
ML18079A409
Person / Time
Site: Salem PSEG icon.png
Issue date: 06/11/1979
From: Miller L
Public Service Enterprise Group
To:
Shared Package
ML18079A408 List:
References
NUDOCS 7906150153
Download: ML18079A409 (15)


Text

.ti ' ti

  • eAVERAGE DAILY UNIT POWER LEVEL IXJCKET NO.

272 UN IT Salem #1 DATE June 11, 1979 COMPLETED BY L. K. Miller TELEPHONE 609-365-7000 X507 May 1979 MONTH DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-NET) (MWE-NET) 1 0 17 0 2 0 18 0 0 19 0 3

0 20. 0 4

0 0 5 21 6 0 22 0 0 0 7 23 8 0 24 0 9 0 25 0 10 0 26 0 11 0 27 0 12 0 28 0 13 0 29 0 14 0 30 0 15 0 31 0 16 0 Pg. 2 of 16 8.1-7.PJ.

7 9 061 5 0 15'3' ' .

DCCKET NJ.: _ _ 50-272 CATE : June 11, 1979

~ BY: L. K. Miller

'lEt.EE'lDNE: 609-365-7000 X507

i. Unit. Naire: S~lem #1 *Notes:
2. Reportinq Period: _ _ _. _Ma:_.._y_l_97_9~~-----

3.. Licel'sed 'llle:aral Power Ufit) : 3338 ';.

4.* Na!Ieplate Ratinq {Gzcss Kfe) : 1135

s. Cesign Electrical Rat.inq (Net .!<fie) --------~
__ 1_09_0_ _ __
6. .MaxjJmJm. Dependable Capacity 7.

(Gross. Kfe) :

MaxilmJm* Dependable Capacity {Net MNe) :

1124 1079

a. If Changes Cccllr ill Capacity Ratings {Itens Nul!Cer* 3 'nirou;h 7) Since Last Repo:c:t, Give Reason:
NONE
        • NONE
9. Power* Level To Which' Restticted, If Aey {Net MNe) :. - - - - - - - - - - - - - - - - - - - - -

10:... Reasons Far Restrictions,. u* Arri: -------NO~~-------------------

'!bis Mcnth' Year to Date Ctmllative 744 '*.*.* 3,623 16,824 ll. EQur.; In Reporting Period l2. Nllni:eJ:'. Of Hours Psactor Was Critical 0 2,184.5 9,841.4 l3. Reactor P.eserve Shutdcwn 5:)urs 0 22.7 22.7 l4. !lours Generator On-Lina 0 2 ,161.3 9,459.3

~ --*~~

15. Unit P.eserve Shlll:down l:Toi.ti:s* .o 0 0
16. Gzcss 'lbemal Energy Generated(MolH) 0 6,482,491 27,467,227 l7. Gress. Electrical Energy Genera.ted(MWH) 0 2,181,770 9,154,580 l8. Net Electrical Energy Generated{mH) (4' 414) 2,081,907 8,668,887 l9. . unit Service Factor 0 59.7 56.2
20. unit Availahiljty Factcr 0 59.7 56.2 2l. unit Capacity Factcr {Usinq MOC Net) 0 53.3 47.8 22:.. Unit Capaci:ey Factor {Usinq DER Net) .o 52.7 47.3
23. unit Forced outage Rate 0 3.0 31.3
24. Shutdoms Scheduled over Next 6 Months {Type, Date, arid Duration of Each) :

NONE

25. If Shut Down At Endo£ Rep:lrt Period~ Estimated oate o~ Startup: _ _ _ _J_u_l__y___2_1__,_1_97_9
26. units In Test Status (Prior to Catlnercial Cperation) : .

Forecast Achieved 9/10/76 12/11/76 11/01/76 12/25/76 8-l-7.R2 Pg. 3 of 16 12/20/76 6/30/77

UNIT smn:roms l\ND PCl'IBR IlEOOCTIONS DOCKET NO. : 50-272

~~~~~~~~~-

REPORT MJlffll May 1979 *UN IT !NAME: Salem #1 DATE: June 11, 1979 .

COMPLETED BY: .L. K. Miller TELEPHONE: 609-365-7000 X507 METIDD OF OORATIOO s11l1ri!tr. LICENSE SYSTEM WIPOOENl' CAUSE 1\ND CORROCTIVE

00. DATE TYP~ (llXIRS) RF.ASON2 ram EVEN!' CODE4 CODE~ ACTION 'IO REACroR REPoRT I PREVENT REOJRRmCE 79-189 4/3/79 5 744 c 1 - - - RC FUELXX Annual Refueling outage 1 2 j 4 5 F: Forced Reason: M:?thod: Exhibit G - Instructions Exhibit 1-Sarre 1-Manual for Preparation of Data Souroa S: Scheduled A-B:Jui?lEl'lt Faiiure(Explain)

B-Maintenance or Test 2-Manual Scram. Entry Sheets for Licensee C-Refueling l-Aut:anatic Scram. Event Report (LER) File D-RegUlatm:y Restriction . 4-other (Explain) (NlJREI}-0161)

E--Operator Training & License Examinatibn F-ildministrative A. IDad Reduction

~ational Error(Explain)

II-Other (Ellplain) B. Continuation of Previous outage.

Page 4 Of 16 B-1-7.Rl .

DOCKET NO.: 50-272 MAJOR PLANT MODIFICA~~S REPORT MONTH May i979 UNIT 9-m: Salem #1 DATE: June 11, 1979 COMPLETED BY: L. K. Miller TELEPHONE: ( 6 09) 365-7000 X507

  • DCR NO. PRINCIPLE SYSTEM SUBJECT lED-0246 Pressurizer Spray Replace positioners for PSl and PS3 lED-0312 Auxiliary Feed Modify controls to allow restarting from Control Room lED-0319 Fire Protection Construct equipment dike around 11, 12 and 13 Chillers lE:C-0415 Transformer Instruments Change watt transducer from Phase 2/N to Phase 2/3 lE~-0416 Spent Fuel Cooling Install tie-in for future heat exchanger lEC-0450 Waste Liquid Add Auxiliary Relay in Control Circuit of 1WL12 lEC-0471 Control Air TGA Replace 1CA129 with pipe nipple lOD-0044 Circulating Water Install sample valves on upper motor bearing reservoirs
  • DESIGN CHANGE REQUEST Page 5 of 16 8-l-7_~Rl

-~*-*

DOCKET NO.: 50-272

  • r.t~JOR PLANT MODIFICATa1S UNIT-.ME: Salem #1 REPORT MONTH May 191'1J June 11, 1979 DATE:

COMPLETED BY: L. K. Miller TELEPHONE: ( 6 09) 365-7000 X507

  • DCR NO. 10CFRS0.59. SAFETY EVALUATION lED-0246 The functional '.operation of the Pressurizer Spray Control Loop remains unchanged. Instruments are to be replaced to improve system reliability.

lED-0312 The basic system design function remains unchanged. The design change permits greater operator flexibility.

lED-0319 Design change is not safety related and will not affect safe operation of plant.

lEC-0415 Safety related **equipment is not affected. This change will improve watt transducer accuracy.

lEC-0416 This design change does not affect any presently performed safety analysis nor does it create any new safety hazards.

The basis of the Tech. Specs. are not affected.

lEC-0450 This design change is not safety related and does not, in any way, affect any safety related systems or the safe shutdown of the unit.

lEC-0471 The subject design change request is non-safety related and does not impair any safety related system function or reliability function. The changes involved are non-nuclear and seismic class 3.

lOD-0044 This change affects a system which is not safety related.

Incorporation of this change will not affect a safety related system.

Page 6 of 16

SUMMARY

OF SAFETY RELATED DEPARTMENT

~*NTENANCE Performance DOCKET NO.:

UNIT N.: ___

DATE :

~~~~

50-272

.......~~~~~~~~~1 s_a_l_em...;....;ti;..;n~------i June 11, 1979

~~~~~__;~~~~~~~--

COMP LETED BY: L. K. Miller REPORT MONTH May 1979 ~~~~~~~~~~~~~--

TELEPHONE: ___6_0_9-_3_6_5_-_7o_o_o__x_5_0_7____~

WORK ORDER EQUIPMENT FAILURE DESCRIPTION CORRECTIVE ACTION NO.

I 900271 Instrument, N41 Out of spec. Calibrated.

Power Range Drawer.

~ 900276 Instrument, N43 Input amps NM301, NM302 Recal. NM301, 302, 307, 1QM431B, Power Range Drawer. Out of Spec. 1QM203A.

900281 Instrument, N31 Detector voltage bistable Reset loss of Det. Voltage Power Range Drawer. setpoint out of spec. bistable.

900284 Instrument, lROllA Calibration check. Check completed.

~00288 Instrument, N42 Out of Spec. Calibrated. I Power ;:Range Drawer.

900293 .Instrument, N32 - - Out of Spec *. --** Clean, tightened connection, Source Range Drawer calibrated.

900294 Instrument, Spare Channel for backup. Installed.

Source Range Det.

900484 Instrument, 1R012B Erratic Alarm. Replaced relay, functionally checked.

900487 Instrument, 1R002. Out of calibration. Calibrated.

900494 Instruments, iROllA Initiate channel alarms. Performed channel function -*

1R012B, *1R012A -*

tests.

902654 Instrument, N32 Counts increased high. Reverted to installed detector.

Source Range Drawer 902659 Instrument, N31 Check, Counts increased 10 Calibrated recorder.

Source Range Drawer. to 150.

902804 Valve Operator, Stroke valve. Stroked valve.

10PR018.

7 of 16 Page

DOCKET NO.: 50-272

~NTENANCE UNIT N . : Salem Ill

SUMMARY

OF SAFETY RELATED DATE: June 11, 1979 DEPARTMENT Performance COMPLETED BY: L. K. Miller REPORT MONTH May 19 79 TELEPHONE: 609-365-7000 X507 WORK ORDER EQUIPMENT FAILURE DESCRIPTION CORRECTIVE ACTION NO.

902805 Valve Operators, Stroke Valves. Stroked valves.

12GB004, 14GB004.

902809 Valve, 10SS107. Stroke valve. Stroked valve.

902811 Valve, 10SS049. Stroke Valve. Stroked valve.

903001 Valve Operator, Position Indication erratic Replaced bezel lamps.

903010 Instrument, N32. Indication.......erratic. Cleaned connectors .

Source Range Drawer.

903024 Instrument, N32 Reads higher than N31. Replaced detector, repaired Source Range Drawer. connector.

903348 Instrument, lTIC- High inlet temperature. Cleaned contacts, calibrated 0627A. switch. .. - ..

903359 Instruments, Out of Spec. Flow. Calibrated.

1FA3165Z-02, 1FA3540Z-01,

... 1F.A3165Z-03, 1FA3540Z-02.

903362 Valve, llAFOll Will not open past halfway. Adjusted controller, adjusted limit switch.

903368 Instrument, Output 2 failed. Replaced, calibrated.

1PC0514A/B.

903370 Instrument, 1PL9493. Gauge failed. Zero adjusted needle.

Q03376 Valve Operator, Will not open. . Adjusted limit switch

  • 11MS018.

903385 Valve Operator, No open indication. Adjusted limit switch.

10CH030.

Page 8 of 16

DOCKET NO.: 50-272

SUMMARY

OF SAFETY RELATED ~NTENANCE UN IT N~

_ __.s=a.....

1...e...

m_...#1..___ _ _ _ _ __

Performance DATE: __J_un_e__l_l_,__1_97_9______~---

DEP ARTMEN.T


~

REPORT MONTH~M~a~y.......,19~7~9--~~~-

COMl?LETED BY:

L. K. Miller TELEPHONE:

609-365-7000 X507 WORK ORDER EQUIPMENT FAILURE DESCRIPTION CORRECTIVE ACTION NO.

904017 Valves, 1188032, Support Maintenance Returned valve to normal.

1388032. Department.

904028 Valve Operator, Will not remain open. Adjusted close limit switch.

10VC002.

904038 Instrument,1LT0732 Out of Calibration. Calibrated.

904055 Instrument , 1FT0530 Out of Calibration. Calibrated.

904789 Instrument, Out of Calibration Replaced module.

1PC0514A/B.

904792 Instrument,. 1FT0640 Out of Calibration. Calibrated. I

. -- ---- I 904794 Instrument, 1LT0501 Out of Calibration Calibrated.

904795 Instrument, 1LT0502 Out of Calibration Calibrated.

904799 Instruments, Out of Calibration. Calibrated.

1FM0542A, 1FM0542B, 1FM0542C.

904801 Instrument, SSAT Remove diode input leads Removed and restored.

1 Gen. Diff. TLA685.

904801 Instrument, SSBT Remove diode input leads Removed and restored.

Gen. Diff. TLB685.

904802 Instrument, Out of Calibration. Calibrated 1FM0522B 1FM0522C.

904805 Instrument, 1FT0512 1FM051A/B out of Calibrated 1FM0512A/B.

calibration .

Page 9 of 16

DOCKET NO.: 50-272 UNIT Nie:: Salem f/l

SUMMARY

OF SAFETY RELATED .NTENANCE Performance DATE.: June 11, 1979 DEPARTMENT May 1979 COMPLETED BY: L. K. Miller REPORT MONTH TELEPHONE: 609-365-7000 X507 WORK ORDER EQUIPMENT FAILURE DESCRIPTION CORRECTIVE ACTION NO.

904806 Instrument, 1FT0540 1FM0540B, 1FC0540A/B,- out Calibrated 1FM0540B, 1FC0540A/B.

of calibration.

I 904807 Valve Operator, Inspect/Rework/Replace Replaced positioner.

12SW008.

904807 Instrument, 1PL0311 Inspect/Rework/Replace Replaced gauges. I I

904807 Valve, 12SW008 Inspect/ Rework/Replace Reworked.

904807 Valve Operator, Inspect/RewO'rk/Replace Replaced control air .solenoid.

15SW024.

904807 Instrument, 1PL0310 I!!spect/Rework/Replace Replaced gauges.

904807 Valve, 15SW015. Inspect/Rework/Replace Reworked.

904807 Valve, 15SW024. Inspect/Rework/Replace. Reworked.

904808 Valve, 16SW015, Inspect/Rework/Replace Reworked.

16SW024 904808 Instruments, Inspect/Rework/Replace Cleaned, Calibrated 1PL0313, 1PL0312, 1PL0260 904808 IValv.e Operator., Inspect/Rework/Replace Replaced control air solenoid.

16SW024.

904809 Instruments; Inspect/Rework/Replace Cleaned, Calibra.ted 1PL0309, 1PL0258, 1PL0308, 1TL3757 ,

~O[f809 Valves, 14SW024, Inspect/Rework/Replace Reworked.

14SW015 Page 10 of 16

50-272

. DOCKET NO.:

SUMMARY

OF SAFETY RELATED ~NTENANCE UNIT Nll-: Salem Ill Performance DATE: June 11, 1979 DEPARTMENT REPORT MONTH May 1979 COMPLETED BY: L. K. Miller TELEPHONE: 609-365-7000 X507 WORK ORDER EQUIPMENT FAILURE DESCRIPTION CORRECTIVE ACTION NO.

904809 Valve Operator, Inspect/Rework/Replace Replaced control air solenoid.

14SW024.

i 904812 Instrument, 1FT0510 No output from 1FM0510A Calibrated.

904814 Instrument, 1PT0506 Out of Calibration. Calibrated.

904815 Instrument, 1PT0505 Out of Calibration Calibrated.

9.04816 Instruments, Out of Calibration. Calibrated.

1TM0505A, 1TM0505C 904819 Instrument, 1FT0113 Out of Calibration. Calibrated.

I 904884 Instrument, 1FT0435 Out of Calibration. Calibrated.

904887 Instrument, 1FT0128 Out of Calibration. Calibrated.

904889 Instrument, 1LT0730 Out of Calibration. Calibrated.

904890 Instrument, 1PT0142 Erratic Output. Calibrated.

904891 Instrument, 1LT0734 Out of Calibration. Calibrated.

9.04892 Instrument,.1FT0511 1FM0511B Out of Calibration Calibrated 1FM0411B.

904899 Instrument, 1FT0520 1FM0520B out of Calibration Calibrated 1FM0520B 904900 Damper, lCAA031, Rework Control Air Solenoid Cleaned 1SV0690 032, 033 1SV0690.

904901 Instruments, lROllA Perform Channel Functional. Performed Functional Sur-1R012B, 1R012A veillance .

Page 11 of 16

N.:

DOCKET NO.: 50-272

SUMMARY

OF SAFETY RELATED ~TENANCE UNIT Salem tfl June 11, 1979 DATE:

DEPARTMENT Performance COMPLETED BY: L. K. Miller REPORT MONTH May 1979 TELEPHONE: 609-365-7000 X507 WORK ORDER EQUIPMENT FAILURE DESCRIPTION CORRECTIVE ACTION NO.

. 904904 Valves, 12GB004, Provide Support for Provided hand sender, stroked 14GB004 Maintenance Department. Valves.

904912 Instruments, 1R012I Perf drm Channel Functions. Performed Functional.

lROllA,. 1R012A.

Q04918 Instruments, lROlH Perform 7 Day Channel Performed functional surveil..:.,

1R012A, 1R012B Functional Surveillance. lance.

905070 Instrument, No alarm, 7 GPM indicated Returned retainer ring to 1FI0940. fl.ow when 0 Flow. positioner. *-***

Page 12 of 16

DOCKET NO.: 50-272

. -* Salem Ill UNIT N4:

SUMMARY

OF SAFETY RELATED &TENANCE June 11, 1979 DATE:

DEPARTMENT Maintenance COMPLETED BY: L. K. Miller REPORT MONTH May 1979 TELEPHONE: 609-365-7000 X507 WORK ORDER EQUIPMENT FAILURE DESCRIPTION CORRECTIVE ACTION NO.

901312 Compressor, Replace compressor with Replaced compressor, unloader.

13 Chiller. spare.

901400 Motor, 15 Serv. Chang*e motor with spare. Replace motor with spare.

Water Pump.

901723 Motor, 12 RC;El. Repair bearing oil lift Repaired junction bo:X:.

pump press. device.

901726 Air Lock, l00 1 :-:E;1; Repair Inner door. Replaced failed cam follower.

Containment.*

901735 Crane, 1 Man-'-. Repair/replace crane motor Cleaned contacts.

ipulator capacitor.

901973 Air Lock, 100' El. Mech. Interlock is jammed/ Replaced cam follower, adjusted.

Containment broken.

901994 Valve, 10CV021. Excessive seal leakoff. Repacked.

902806 Valve, 10NT026. Repair, leaks thru. Replaced dis:c, spring, gasket.

902812 Valve, 10NT034. Repair, leaks. Rebuilt valve.

902850 Breaker, 11 Serv. Repair, Replace cover and Replaced Term. Block, Repaired Water Pump 4KV. Term. block. Cover.

903058 Sump, 11 Cont. ... Inspect, clean out. Cleaned debris from sump ..

903058 Sump, 12 Cont. Inspect, clean out. Cleaned debris from sump.

903286 Valve, 11RC027 Split packing gland fol-: Replaced packing follower.

lower.

903289 Compressor, 12 Trips on oil pressure. Added oil and set unlo.aders.

Chiller.

Page 13 of 16

DOCKET NO.: 50-272

~~----~--------------

SU~~ OF SAFETY RELATED ~TENANCE UN IT N~:~s_a_1_em__H_1____~---------

DATE: June 11, 1979 DEPARTMENT Maintenance REPORT MONTH May 1979 COMPLETED BY:__,;L;;;.-.*~K~*--M~il~l~e=r--..~~~~~

TELEPHONE: 609-365-7000 X507 WORK ORDER EQUIPMENT FAILURE DESCRIPTION CORRECTIVE ACTION NO.

903342 Screen, 14 Service Screen runs only in inch Calibrated lPD-2734 Water. mode.

903409 Valve, 14SJ025. Repack. Repacked.

903417 Valve 12SJ025. Repack. 0 Repacked.

903425 Valve, 11SJ023. Repack. Repacked.

903426 Valve, 11SJQ25. R~pack. Repacked.

903766 Valve, 12SW025. Install new diaphragm. Replaced diaphragm.

904870 Air lock, 100' El.' Inner door wil_l not close....

~

Replaced cam follower.

Containment.

Page 14 of 16

~.

,.. . ..l ~

SALEM UNIT I OPERATING

SUMMARY

MAY 1979 5-1 thru REFUELING OUTAGE.

5-31 Page 15 of 16

  • REFUELING INFORMATION '

DOCKET NO.: 50-272 UN IT: Salem #1 DATE: June 11,. 1979 COMPLETED. BY:. L. K. Miller TELEPHONE: 609-365-7000 x 5*07 MONTH:~_ _ M_a_y_l_9_7_9_______________

1. Refueling information has changed from last month:

YES X NO

2. Scheduled date of next* refueling: March 29, 1980
3. Scheduled date* for restart following. refueling: May 2 5, 19 8 O
4. A. Will Technical. Specification changes or other. license
  • amend.men ts be required'? YES NO NOT DETERMINED TO-DATE May 19 7 9

- B-.. *- Has the* reload* fue1. -design.. been reviewed. by the Station Operat~~g Review Committee?

If no, when is it scheduled?

YES

--- NO X 5.

February 1980 Scheduled date(s) for submitting proposed licensing action:

February 1980 (If required).

6. Importan.t licensing considerations associated with refueling:

NONE

7. Number of Fuel Assemblies:

A. In-Core 193 B. In Spent Fuel Storage* 0

8. Present licensed spent fuel storage capacity: 264 Future spent fuel storage capacity*: 1,170
9. Date of last refueling that can be discharged to the spent fuel pool assuming the present 'licensed capacity: April 1982 Page 16 of 16 8-l-7.R4