- 1 Distribution'"'
Docket File NRC PDR Local PDR LWR #3 File v'assallo Wi 11 iams Parr Dromerick Rushbrook OELD IE ( 3)
- BCC:
- JBuchanan TAbernathy ACRS (16)
Docket No. 50-311 APR 2 3 1979 Mr. R. L. Mittl, General Manaqer Licensing and Environment Engineering and Construction Department
- Public Service Electric and Gas Company 80 Pa,rk Place
- Newark, New Jersey 07101
Dear Mr. Mittl:
'SIJB.JECT:. SALEM NUCLEAR GENERATING STATION, UNIT NO. 2 STEAM GENERATOR
- CHANNELHE.t\\D CRACKING In your letter dated March 30, 1979 regarding the Salem Unit 2 st~am generators~ you stated that periodic penetrant tests performed on Unit 2 steam generator channelhead cladding exhibited increasingly numerous crack indications.* You proposed that the condition of Unit 2
- steam generator cha1inel head cladding during service be inferred by using the results from periodic ultrasonic examinations that are to be performed to monitor cracking in the Unit 1 steam generator channelhead cladding.
We have evaluated your propos~l and have determined that it is unacceptable because the crack indications of Unit 2 channelheads have increased in severity and extent during precritical operation.
We require* that you demonstrate the integrity of the channel heads of* Unit 2 by monitoring the cracks in Unit 2. This will provide more val id information on the condition of the Unit 2 channel heads, which may not have been manufactured*
entirely similar to those of Unit 1. Furthermore, the imperfections monitored by inspecting Unit 2 would be more responsive to the effects of the Unit 2 environment.
I I
- /
i I.
/./
'/f **:
/
/
,/,/,,'
/
,., /
I.
/' ;*
,~/,
~"'
/
,I; -
./
~
/
. t
. i t
1-t I
OFFICE,;...
- ***** *'* ***** *. *.......... * ********,. * ;,~..........
- ****** '.. * * * *.... * * ** * * ** *. *. * *. * * * * * * * * * * * *
- 0 SURN.......
......................... ~........................ U.:*************; :** ~.,.... :*...... :,, **~ **:*:**............................. *****
DATE~
- ,.. *:.************* ************************** ************************"' *.******.o****************** **********************
- NJLC FORM 318 (9*76) NRCM 02.40
.* U 0 S 0 GOVER~M.ENT PRINTING OFF;ICE: t D7ll - 2G5 '"'769
APR 2 3 1979 Mr. R. L. Mittl, General Manager 2 -
\\*Je require that you provide your pl an for monitoring the observed Unit 2 channel head imperfections,b.Y monitoring the Unit 2 chan_nel heads.
In order to maintain,otfr review schedule your submittal of the proposed pl an for monitoring the *unit 2 channel head imperfections is required promptly.
Please contact us if yo~ desire any discussion or cl~rification of tHe above request~
Sincerely,*
Original signed by A. W. Dromerick Olan D. Parr, Chief
- Light Water React.*~rs* Branch No. 3 Division of Project Management cc: -Richard Fryling, Jr., Esq.
OFFICE..
Assistant General Counsel Public Service Electric & Gas Comp~ny 80 Park Pl ace Newark~ New Jersey 07100 Mark Wetterhahn, Esq.
Conner, Moore & Caber 1747 Pennsylvania.£\\venue, N. W.
Suite 1050 Washington, D. C.
20006 Mr. Leif J.. Norr-holm
~. S. Nuclear Regulato0y Commission*
Region I Drawer I Hancocks Bridge, New Jersey 08038
/
f3URNA!;'IE.. :A.ci.~~~L.t J~~~*.*.*.. :-.-.*.*.-.:*.**.*.**.*.*.*.*.:-.:*:*.*.:*.*.*.* :::*.:: ::::;:::::::::::::.::::::::::::::::::::::::: :*.*.:*.*.:*.:.-.:::-.-.-.*.-.*.::
DATE~... ~(~'/.?.?..... "~!2~.!?.~............... ::::................................. ~....................................... ;...............
- NK.C FORM 318 (9*76) NRCM 0240
-ti. U.S. GOVERNMEtNT PRINTING OFFICE: t D7e - 2138 - 700