Hematite Decommissioning Project Procedure: HDP-PR-FSS-701, Final Status Survey Plan Development Westinghouse Non-Proprietary Class 3 Revision: 4 Appendix P-6, Page 1 of 2 APPENDIX P-6 FSS FIELD LOG Quality Record Survey Area:
LSA 08
==
Description:==
Central Open Land Area (Tc-99 SEA)
Survey Unit:
12
==
Description:==
Class 1 Area 7; (Survey Unit between 08-11 and 08-13)
FSS Field Log:
Date/Time:
03/18/16 Observation or Comment:
Prior to performing the GWS of LSA 08-12, a quality walk down of the area was conducted. Isolation controls consisting of green and white rope were in place. Asphalt and concrete pieces were removed from the area and disposed of properly before the GWS was performed. Weather conditions were cool and overcast at 51 degrees Fahrenheit. Ludlum 2221 and 44-10 B and N were used to perform the GWS. The background for instrument B was 10,500 GCPM. The background for instrument N was 10,000. The GWS was started at 0900 and paused at 1055. The GWS resumed at 1300 and was completed at 1530. LSA 08-12 was exited and the personnel returned to the office to process data and perform instrument post-checks.
GWS Files Generated:
LSA_08_12_031816_B_JMB LSA_08_12_031816_N_JH Technician Jacob Boxdorfer Jeff Hoffman 03/18/16 Following a GWS using Ludlum 2221 and 44-10 B and N systematic sample locations were taken along with one biased sidewall sample. The background for instrument B was 10,500 GCPM. The background for instrument N was 10,000. The weather conditions were cool and overcast at 51 degrees Fahrenheit.
Sample ID:
L08-12-18-T-E-B-00 Kyle Weldon Michael Dekeyser 03/24/16 Prior to performing the GWS of LSA 08-12, a quality walk down of the area was conducted. Isolation controls consisting of green and white rope were in place. Weather conditions were cool and overcast at 52 degrees Fahrenheit.
Ludlum 2221 and 44-10 B were used to perform the GWS. The background for instrument B was 10,500 GCPM. The GWS was started at 0805 and completed at 1115. LSA 08-12 was exited and the personnel returned to the office to process data and perform instrument post-checks.
GWS Files Generated:
LSA_08_12_032416_B_JMB Jacob Boxdorfer
Hematite Decommissioning Project Procedure: HDP-PR-FSS-701, Final Status Survey Plan Development Westinghouse Non-Proprietary Class 3 Revision: 4 Appendix P-6, Page 2 of 2 APPENDIX P-6 FSS FIELD LOG Quality Record Survey Area:
LSA 08
==
Description:==
Central Open Land Area (Tc-99 SEA)
Survey Unit:
12
==
Description:==
Class 1 Area 7; (Survey Unit between 08-11 and 08-13)
FSS Field Log:
Date/Time:
03/28/16 Observation or Comment:
Prior to commencing the biased sampling of LSA 08-12 the FSS Supervisor conducted a task-specific safety brief. The FSS personnel performed a quality walk-down to ensure I&C measures were in place. Weather conditions were clear and cool at 63°F. Biased sampling commenced at 1555 and was secured at 1635. The FSS personnel returned to the FSS office to prepare samples for shipment.
Sample IDs:
L08-12-19-T-R-B-00, L08-12-20-T-R-B-00, L08-12-21-T-R-B-00, L08-12-22-T-R-B-00, L08-12-23-T-R-B-00, L08-12-24-T-E-B-00, L08-12-25-T-E-B-00, L08-12-21-T-R-Q-00 Technician Jahmai Williams 03/29/16 Prior to continuing the GWS and biased sampling of LSA 08-12 the FSS Supervisor conducted a task-specific safety brief. The FSS personnel performed a quality walk-down to ensure I&C measures were in place.
Weather conditions were clear and cool at 63°F. General area background was measured at 8K-10K. The GWS commenced at 1349 and was secured at 1501. A second GWS was conducted from 1615 to 1621. Biased sampling commenced at 1620 and concluded at 1630. LSA 08-12 was exited and the personnel returned to the office to prepare samples for shipment, process data and perform instrument post-checks.
GWS Files Generated:
LSA_08_12_032916_N_JW LSA_08_12_032916_N_JW(POST)
Jahmai Williams