Text

h/d

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION I

631 PARK AVENUE

KING OF PRUSSIA, PENNSYLVANl.A 19406

Docket Nos. 50-272

50-311

JAN 0 2 1979

Public Service Electric and Gas Company

ATTN:

Mr. F. W. Schneider

Vice President - Production

80 Park Place

Newark, New Jersey 07101

Gentlemen:

Subject:

Combined Inspection 50-272/78-30; 50-311/78-52

This refers to the inspection conducted by Mr. J. R. White of this

office on December 12-15, 1978 at the Salem Nuclear Generating Station,

Units l and 2 of activities authorized by NRC License Nos. DPR-70; CPPR-

53 and to the discussions of our findings held by Mr White with Mr. H.

J. Midura of your staff at the conclusion of the inspection.

Areas examined during this inspection are described in the Office of

Inspection and Enforcement Inspection Report which is enclosed with this

letter. Within these areas, the inspection consisted of selective

examinations of procedures and representative records, interviews with

personnel, and observations by the inspector.

Our inspector also verified the steps you have taken to correct the item

of noncompliance brought to your attention in a letter dated June 12,

1978.

We have no further questions regarding your action at this time.

Based on the results of this inspection, it appears that certain of your

activities were not conducted in full compliance with NRC requirements,

as set forth in the Notice of Violation, enclosed herewith as Appendix

A.

These items of noncompliance have been categorized into the levels

as described in our correspondence to you dated December 31, 1974.

This

notice is sent to you pursuant to the provisions of Section 2.201 of the

NRC's "Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

Section 2.201 requires you to submit to this office, within twenty (20)

days of your receipt of this notice, a written statement or explanation

in reply including:

(l) corrective steps which have been taken by you

and the results achieved; (2) corrective steps which will be taken to

avoid further items of noncompliance; and (3) the date when full compli-

ance will be achieved .

790307013'-

Public Service Electric and Gas Company

JAN 0 2 1979

2

In accordance with Section 2.790 of the NRC's

11Rules of Practice," Part

2, Title 10, Code of Federal Regulations, a copy of this letter and the

enclosures will be placed in the NRC's Public Document Room.

If this

report contains any information that you (or your contractor) believe to

be proprietary, it is necessary that you make a written application

within 20 days to this office to withhold such information from public

disclosure. Any such application must be accompanied by an affidavit

executed by the owner of the information, which identifies the document

or part sought to be withheld, and which contains a statement of reasons

which addresses with specificity the items which will be considered by

the Commission as listed in subparagraph (b) (4) of Section 2.790.

The

information sought to be withheld shall be incorporated as far as possible

into a separate part of the affidavit. If we de not hear from you in

this regard within the specified period, the report will be placed in

the Public Document Room.

Should you have any questions concerning this inspection, we will be

pleased to discuss them with you.

Enclosures*

1. Appendix A, Notice of Violation

Sincerely,

G ri~.~~

F el Facility and Materials Safety

Branch

2.

Office of Inspection and Enforcement Inspection

Combined Report Numbers 50-272/78-30; 50-311/78-52

cc w/encls:

F. P. Librizzi, General Manager - Electric Production

E. N. Schwalje, Manager - Quality Assurance

R. L. Mittl. Genera1 Manager - Licensing and Environment

H. J. Midura, Manager - Salem Generatirig Station