ML18069A000
| ML18069A000 | |
| Person / Time | |
|---|---|
| Site: | NuScale |
| Issue date: | 03/10/2018 |
| From: | NRC |
| To: | NRC/NRO/DNRL/LB1 |
| References | |
| Download: ML18069A000 (3) | |
Text
1 NuScaleDCRaisPEm Resource From:
Chowdhury, Prosanta Sent:
Saturday, March 10, 2018 6:48 PM To:
Request for Additional Information Cc:
Lee, Samuel; Cranston, Gregory; Murray, Demetrius; Kent, Lauren; D'Agostino, Amy; NuScaleDCRaisPEm Resource
Subject:
FW: Request for Additional Information No. 381 eRAI No. 9397 (Ch. 18)
Attachments:
Request for Additional Information No. 381 (eRAI No. 9397).pdf Attached please find NRC staffs request for additional information (RAI) concerning review of the NuScale Design Certification Application.
Please submit your technically correct and complete response within 60 days of the date of this RAI to the NRC Document Control Desk.
If you have any questions, please contact me.
Thank you.
Prosanta Chowdhury, Project Manager Licensing Branch 1 (NuScale)
Division of New Reactor Licensing Office of New Reactors U.S. Nuclear Regulatory Commission 301-415-1647
Hearing Identifier:
NuScale_SMR_DC_RAI_Public Email Number:
409 Mail Envelope Properties (BN7PR09MB260983F14A764B033E22B81D9EDD0)
Subject:
FW: Request for Additional Information No. 381 eRAI No. 9397 (Ch. 18)
Sent Date:
3/10/2018 6:48:08 PM Received Date:
3/10/2018 6:48:28 PM From:
Chowdhury, Prosanta Created By:
Prosanta.Chowdhury@nrc.gov Recipients:
"Lee, Samuel" <Samuel.Lee@nrc.gov>
Tracking Status: None "Cranston, Gregory" <Gregory.Cranston@nrc.gov>
Tracking Status: None "Murray, Demetrius" <Demetrius.Murray@nrc.gov>
Tracking Status: None "Kent, Lauren" <Lauren.Kent@nrc.gov>
Tracking Status: None "D'Agostino, Amy" <Amy.D'Agostino@nrc.gov>
Tracking Status: None "NuScaleDCRaisPEm Resource" <NuScaleDCRaisPEm.Resource@nrc.gov>
Tracking Status: None "Request for Additional Information" <RAI@nuscalepower.com>
Tracking Status: None Post Office:
BN7PR09MB2609.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 556 3/10/2018 6:48:28 PM Request for Additional Information No. 381 (eRAI No. 9397).pdf 74820 Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received:
Request for Additional Information No. 381 (eRAI No. 9397)
Issue Date: 03/10/2018 Application
Title:
NuScale Standard Design Certification 048 Operating Company: NuScale Power, LLC Docket No.52-048 Review Section: 18 - Human Factors Engineering Application Section:
QUESTIONS 18-19 Title 10 of the Code of Federal Regulations (10 CFR) Section 52.47(a)(8) requires an applicant for a design certification to provide a final safety analysis report (FSAR) that must include the information necessary to demonstrate compliance with any technically relevant portions of the Three Mile Island requirements set forth in 10 CFR 50.34(f), except paragraphs (f)(1)(xii),
(f)(2)(ix), and (f)(3)(v). Section 10 CFR 50.34(f)(2)(iii) requires an applicant to "Provide, for Commission review, a control room design that reflects state-of-the-art human factor principles prior to committing to fabrication or revision of fabricated control room panels and layouts. Chapter 18, Human Factors Engineering, of NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition, and NUREG-0711, "Human Factors Engineering Program Review Model, identify criteria the staff uses to evaluate whether an applicant meets the regulation. The applicant stated in the FSAR, Tier 2, Section 18.0, "Human Factors Engineering - Overview," that its human factors engineering (HFE) program incorporates accepted HFE standards and guidelines including the applicable guidance provided in NUREG-0711, Revision 3.
NUREG-0711, Section 11.4.3.6.4, criterion 2 says, To assure that the participants performance is representative of plant personnel, the applicants training of participants should result in near asymptotic performance (i.e., stable, not significantly changing from trial to trial) and should be tested for such before conducting the validation.
In Section 4.6.4 of the V&V IP the applicant states, To assure near-asymptotic performance and a consistent level of proficiency between individuals making up the operating crews, only participants who have successfully completed the training program and have reached an acceptable level of proficiency are considered to be qualified for operating crew assignment. Please clarify how participants proficiency levels will be assessed prior to conducting validation testing.