ML18068A455

From kanterella
Jump to navigation Jump to search

Forwards Correction to Safety Evaluation of Third 120-month Interval Inservice Insp Program & Requests for Relief. Incorrect Info Was Stated in Original Safety Evaluation
ML18068A455
Person / Time
Site: Palisades Entergy icon.png
Issue date: 10/14/1998
From: Carpenter C
NRC (Affiliation Not Assigned)
To: Haskell N
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
Shared Package
ML18068A456 List:
References
TAC-M93628, NUDOCS 9810200173
Download: ML18068A455 (3)


Text

)

i r

\\-.,.1 t

Mr. Nathan L. Haskell

  • Director, Licensing Palisades Plant 27780 Blue Star Memorial Highway Covert, MI 49043 October 14, 1998

SUBJECT:

PALISADES PLANT - CORRECTION TO SAFETY EVALUATION OF THE THIRD 120-MONTH INTERVAL INSERVICE INSPECTION PROGRAM AND ASSOCIATED REQUESTS FOR RELIEF (TAC NO. M93628)

Dear Mr. Haskell:

By letter dated January 9, 1997, we transmitted the staffs safety evaluation (SE) and Idaho National Engineering Laboratory's (INEL) technical evaluation report (TER) related to the Palisades Plant Third 10-year Interval lnservice Inspection (ISi) Program Plan and associated Requests for Relief. Your staff subsequently identified a discrepancy between the staffs SE and the INEL TER regarding Request for Relief No. RR-11.

The staffs SE, in the last paragraph on page 2, states: "The licensee's proposed alternative to perform manual examinations from the outside surface of the reactor pressure vessel (RPV) lower head meridional welds provides reasonable assurance of operational readiness* of the RPV lower head meridional welds." The INEL TER, in the third paragraph on page 10, states:

"The examinations that can be performed from the inside surface will provide reasonable assurance of structural integrity for the lower head meridional welds." Emphasis has been added in both references.

We have reviewed this discrepancy and have det~rmined that an error was made in preparing the staffs SE. The staff's SE should state, "The licensee's proposed alternative to perform manual examinations from the inside surface of the reactor pressure vessel (RPV) lower head meridional welds provides reasonable assurance of operational readiness of the RPV lower head meridional welds." A corrected staff SE is enclosed. The enclosed SE also includes a footnote that updates the status of Request for Relief RR-09. We regret any inconvenience this error may have caused. If you have any questions regarding this letter, please contact Robert Schaaf of my staff at (301) 415-1312.

Sincerely, ORIGINAL SIGNED BY


~- ------- ---- ------

Cynthia A. Carpenter, Project Director Project Directorate 111-1 9810200173 981014 PDR ADOCK 05000255,I/

P

_PDR _ :J Docket No. 50-255 Division of Reactor Projects - 111/IV Office of Nuclear Reactor Regulation

Enclosure:

See attached

'.*? C ~ C ]_ 3 cc w/encl: See next page DISTRIBUTION: See attached list DOCUMENT NAME: G:\\WPDOCS\\PALISADE\\PAL93628.COR

  • See previous concurrence To receive a copy of this document, indicate in the box C=Copy w/o attachmenUenclosure E=Copy with attachment/enclosure N = No copy OFFICE PM:PD31 LA:PD31
  • BC:ECGB
  • OGC D:PD31 NAME RSchaaf:d CJamerson GBagchi MYoung DATE 10/ t) /98 101 B 09/28/98 10/07/98 10/

FFICIAL RECORD COPY

Mr. Nathan L. Haskell Consumers Energy Company cc:

Mr. Thomas J. Palmisano Site Vice President Palisades Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043 Mr. Robert A. Fenech, Sr Vice Pres Nuclear, Fossil, and Hydro Operations Consumers Energy Company 212 West Michigan Avenue Jackson, Michigan 49201 Arunas T. Udrys, Esquire Consumers Energy Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region Ill U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, Illinois 60532-4351 Jerry Sarno, Supervisor Covert Township P. 0. Box 35 Covert, Michigan 49043 Office of the Governor P. 0. Box 30013 Lansing, Michigan 48909 U.S. Nuclear Regulatory Commission Resident Inspector's Office Palisades Plant 27782 Blue Star Memorial Highway Covert, Michigan 49043 Palisades Plant Drinking Water and Radiological Protection Division Michigan Department of Environmental Quality 3423 N. Martin Luther King Jr Blvd P. 0. Box 30630 CPH Mailroom Lansing, Michigan 48909-8130 Michigan Department of Attorney ~------

General Special Litigation Division 630 Law Building P.O. Box 30212 Lansing, Michigan 48909 August 1998

Distribution for Letter to Consumers Energy Co.. Palisades Plant. dated: October 14, 1998 DocketFile (50-255)

PUBLIC PD3-1 Rdg E. Adensam (EGA 1)

R. Schaaf C. Jamerson G. Hill (2)

G. Bagchi

. T. Mclellan T. Hiltz OGC ACRS B. Burgess, RI 11 SEBO (TLH3)

/

/