ML18068A426

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-255/98-12 on 980706-10 & 20-24 & Nov. Insp Reviewed Engineering & Technical Support Provided to Plant & Effectiveness of Controls in Identifying,Resolving & Preventing Problems
ML18068A426
Person / Time
Site: Palisades 
Issue date: 09/02/1998
From: Grobe J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Thomas J. Palmisano
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
Shared Package
ML18068A427 List:
References
50-255-98-12, NUDOCS 9809090201
Download: ML18068A426 (3)


See also: IR 05000255/1998012

Text

Mr. Thomas J. Palmisano

Site Vice President

September 2, 1998

Palisades Nuclear Generating Plant ..

27780 Blue Star Memorial Highway

Covert, MI 49043-9530

SUBJECT:

NRC INSPECTION REPORT NO. 50-255/98012 AND NOTICE OF VIOLATION

Dear Mr. Palmisano

On July 24, 1998, the NRC completed an inspection at your Palisades facility. The focus of this

inspection was to review engineering and technical support provided to the plant and the

effectiveness of your controls in identifying, resolving, and preventing problems. The inspection

also included review of previously identified inspection items. The enclosed report presents the *

results of that inspection.

Overall, the team concluded* that the engineering and technical support provided by the design

and system engineering groups was effective. In particular, implementation* of the modification

and the 10 CFR 50.59 processes, as well as the condition reporting system appeared to be

functioning well. The team also concluded that Palisades had an effective program for

identifying, resolving, and preventing problems. Corrective actions and enhancements to the

program over the pa$t two years had resulted in improvements.

Based on the results of this inspection, the NRC has determined that a violation of NRC

requirements occurred. The violation is cited in the enclosed Notice of Violation (Notice) and

the circumstances surrounding it is described in detail in the subject inspection report. The

NRC has concluded that information regarding the reason for the violation, the corrective

actions taken and planned to correct the violation and prevent recurrence is already adequately

addressed on the docket in LER 96-013 and Inspection Report No. 50-255/94002. Therefore,

you are not required to respond to this letter unless the description therein does not accurately

reflect your corrective actions or your position. In that case, or if you choose to provide

additional information, you should follow the instructions specified in the enclosed notice .

T. Palmisano

-2-

In accordance with 1OCFR2.790 of the NRC's "Rules of Practice," a copy of this letter, its

enclosures, and your response, if you choose to provide additional information, will be placed iil

the NRC Public Document Room.

Sincerely

~ro=~

Division of Reactor Safety

Docket No.: 50-255

License No.: DPR-20

Enclosures:

1. Notice of Violation

2. Inspection. Report

No. 50-255/98012(DRS)

cc w/encls:

R. Fenech, Senior Vice President, Nuclear

Fossil and Hydro Operations *

N. Haskell, Director, Licensing

R. Whale, Michigan, Public Service Commission

Michigan Department of Environmental Quality

Department of Attorney General (Ml)

Emergency Management Division, Ml Department

of State Police

DOCUMENT NAME: G:/DRS/PAL98012.DRS

OFFICE

Rill/DRS

NAME

RWestberg:sd

DATE

08/:i.rl /98

08~ 98 \\"

OFFICIAL RE

,0

...

'.~.

T. Palmisano

Distribution: *

CAC (E-Mail)

Project Mgr., NRR w/encls

J. Caldwell, Riii w/encls

C. Pederson, Riii w/encls

B. Clayton, Riii w/encls

SRI Palisades w/encls

DRP w/encls

TSS w/encls

DRS (2) w/encls

Rll 1 PRR w/encls

PUBLIC IE-01 w/encls

Docket File w/encls

GREENS

IEO (E-Mail)

DOCDESK (E-Mail)

,.. \\ ;'! .. ' ,.

r* ..

___
uu ... )0
  • t.

-3-