ML18066A304

From kanterella
Jump to navigation Jump to search
Forwards Palisades Nuclear Plant SG Tube Inservice Insp, Per Plant TS 6.6.9b.Ltr Contains No New Commitments & No Revs to Existing Commitments
ML18066A304
Person / Time
Site: Palisades Entergy icon.png
Issue date: 09/24/1998
From: Haskell N
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18066A305 List:
References
NUDOCS 9810020399
Download: ML18066A304 (1)


Text

  • . ..:. *~ ti; A CMS Energy Company Palisades Nuclear Plant Tel: 616 764 2276 27780 Blue Star Memorial Highway Fax: 616 764 2490 Covert. Ml 49043 Nathan L. Haskell Director. Licensing September 24, 1998 U.S. Nuclear Regulatory Commission ATIN: Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT SPECIAL REPORT ON 1998 INSERVICE INSPECTION OF STEAM GENERATOR TUBES Attached is a Special Report on the Palisades steam generator tube inservice inspection which was completed on May 14, 1998. Palisades Technical Specification 6.6.9b requires that this report be submitted to the Nuclear Regulatory Commision within 12 months following completion.

Our letter dated May 15, 1998, reported that eight tubes were plugged in Steam Generator E-50A and three tubes were plugged in Steam Generator E-508 as a result of the inspection. Four of the tubes in Steam Generator E-50A were plugged as a preventive measure only.

SUMMARY

OF COMMITMENTS This letter contains no new commitments and no revisions to existing commitments.

~*

athan L. Haskell rector, Licensing CC Administrator, Region Ill, USNRC Project Manager, NRR, USNRC NRC Resident Inspector - Palisades Enclosure

(

\