June 29, 1998

Mr. Thomas J. Palmisano

Site Vice President and General Manager

Palisades Nuclear Generating Plant

27780 Blue Star Memorial Highway

Covert, Ml 49043-9530

SUBJECT:

NOTICE OF VIOLATION (NRC INSPECTION REPORT NO. 50-255/98004(DRS))

Dear Mr. Palmisano:

This will acknowledge receipt of your letter dated June 17, 1998, in response to our letter

dated May 18, 1998, transmitting a Notice of Violation associated with a failure to conduct a

J

comprehensive written requalification examination for licensed operators at the Palisades Nuclear

Plant. We have reviewed your corrective actions and have no further questions at this time.

These corrective actions will be examined during future inspections.

Docket No.: 50-255

License No.: DPR-20

Sincerely,

1G~&

n A. Grobe, Director

sion of Reactor Safety

Enclosure:

Ltr dtd 6/17/98 from T. Palmisano,

Consumers Energy to USNRC

See Attached Distribution

To receive a co

OFFICE

Riii

NAME

Bielby:sd ff4"'~

DATE

06~98

980i020340 980629

PDR

ADOCK 05000255

G

PDR

T. Palmisano

-2-

cc w/o encl:

R. Fenech, Senior Vice

President, Nuclear, Fossil

and Hydro Operations

N .. Haskell, Director, Licensing

cc w/encl:

R. Whale, Michigan

Distribution:

CAC (E-Mail)

Public Service Commission

Michigan Department of

Environmental Quality

Department of Attorney General (Ml)

Emergency Management

Division, Ml Department

of State Police

Project Mgr., NRR w/encl

C. Paperiello, Rll I w/encl

J. Caldwell, Riii w/encl

B. Clayton, Riii w/encl

SRI Palisades w/encl

DRP w/encl

TSS w/encl

DRS w/encl

Riii PRR w/encl

PUBLIC IE-01 w/encl

Docket File w/encl

GREENS