ML18064A652

From kanterella
Jump to navigation Jump to search
Record of Telcon W/Plant on 950228 Re Status of Palisades PTS Review.Staff Concluded That by Performing Calculations in Strict Compliance w/10CFR50.61,plant Would Not Reach Screening Until Year 2000
ML18064A652
Person / Time
Site: Palisades Entergy icon.png
Issue date: 03/06/1995
From: Gamberoni M
NRC (Affiliation Not Assigned)
To:
References
NUDOCS 9503210287
Download: ML18064A652 (1)


Text

\\~

)

NOTE TO:

FROM:

March 6, 1995 Cynthia Carpenter, Acting Director Project Directorate 111-1 M~

Marsha Gamberoni

.Project Manager

Project Directorate 111-1

SUBJECT:

RECORD OF TELEPHONE CONVERSATION, STATUS OF PALISADES PRESSURIZED
THERMAL SHOCK (PTS) REVIEW On February 28, 1995, a telephone call was held between the staff and Palisades plant to discuss the status of the Palisades PTS review.

This note provides documentation of that discu~sion. The staff informed Palisades that it is currently reviewing the information Palisades provided in recent submittals (November 1994 - January 1995), to show compliance with 10 CFR 50.61.

These submittals updated Palisades? PTS evaluation which included the results of testing performed on weld samples from Palisades' retired steam generators.

At the time of the telephone call, the staff had not reached a final determination.

Based on the results of the review to date, the staff has concluded that by performing calculations in strict complianc~ with 10 CFR 50.61, Palisades would not reach th~ screening criteria until the year 2000.

However, the staff has con.cerns about the variability in the chemistry data and is performing additional analysis to better understand the issue:

~.

The review is expected to be completed within the next few weeks and a safety evaluation should be issu*ed by the e.nd of March... A'meeting to discuss the results of the review could be scheduled after the licensee has received the safety evaluation and has time to develop questions and prepare for discussion.*

Palisades ;stated it is consider~ng annealing to get to end o~ license.

Discussions on annealing will continue following issuan<;:e of the PTS safety evaluation.

Docket 50..:255 DISTRIBUTION:

BS heron (Docl<eCFi-i-e*\\

Licensee and Service Li st GLainas PUBLIC --

JStrosnider CCarpenter KWichman MGamberoni BElliot CJamerson EHacket BMcCabe DOCUMENT NAME:

G:\\WPDOCS\\PALISADE\\TELECON.228 To receive a copy of this document, Indicate In the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy *see Previous Concurrence OFFICE LA:PD31 PM:PD31 BC:EMCB*

N NAME CJamerson DATE 3

to C\\.S 3

r,, G6 03/06/95 OFFICIAL RECORD COPY 210005 9503210287 95030b PDR ADOCK 050002551 p

PDR,;

~------

_____________.J....._,_L__ -----