,1J i
..-',~' Vice President, Nucle,Operations Consumers Power Company October 28, 1994 ti'
(
Palisades Plant.
27780 Blue Star Memorial Highway Covert, MI 49043
SUBJECT:
PALISADES PLANT - REVIEW OF PALISADES CONTAINMENT TWENTIETH YEAR TENDON SURVEILLANCE REPORT (TAC NO. M84017)
Dear Mr. Fenech:
By letter dated June 16, 1992, as supplemented by information contained in letters dated February 7 and September 8, 1994, you submitted for staff review a report on the results for the twentieth year physical surveillance of the Palisades Plant containment building post-tensioning system.
In accordance with the plant technical specifications (TS), you are required.to perform periodic tendon surveillances. The surveillance was performed in accordance with the procedure contained in Regulatory Guide (RG) 1.35, Revision 3.
On the basis of the results of the twentieth year surveillance and inspection of the various elements of the system as compared to the criteria established in the TS and in RG 1.35, Revision 3, you concluded that no abnormal degradation has occurred in the post-tensioning system used in the Palisades containment.
The staff concurs with this conclusion that the Palisades
.. containment building has experienced no abnormal degradation of the post-tensioning system.
However, you should use all the available data and perform an adequate regression analysis, as discussed in the enclosed safety evaluation, both before and after the 1997 scheduled surveillance.
This completes our review, if you have ahy questions regarding this subject, please contact Marsha Gamberoni at {301) 504-3024.
Docket No. 50-255
Enclosure:
Safety Evaluation cc w/encl:
See next page DISTRIBUTION (Docket.:: Ffl-e-J NRC & Local PDRs JRoe JHannon MGamberoni OGC WKropp, Riii CPTan OFFICE LA: PD31 PM:PD31 Sincerely, ORIGINAL SIGNED BY Marsha Gamberoni, Project Manager Project Directorate 111-1 Division of Reactor Projects - Ill/IV Office of Nuclear Reactor Regulation PD31 Reading LLessler ACRS (10)
D:PD31 ~
NAME LLess l er MGamberonM JHannon ~
DATE 10/).1/94 10/Z..7f'/94 10/).1/94 OFFICIAL RECORD COPY -
'FILENAME: G:\\WPDOCS\\PALISADE\\PAL84017.SE 9411040263 941028 PDR ADOCK 05000255 p
/
Mr. Robert A. Fenech Consumers Power Company cc:
Mr. Thomas J. Palmisano Plant General Manager Palisades Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Mr. Kurt M. Haas Plant Safety and Licensing Director Palisades Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043 M. I. Miller, Esquire Sidley & Austin 54th Floor One First National Plaza Chicago, Illinois 60603 Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, Illinois 60532-4351 Jerry Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 U.S. Nuclear Regulatory Commission Resident Inspector Office Palisades Plant 27782 Blue Star Memorial Highway Covert, Michigan 49043 Palisades Plant Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health Department of Public Health 3423 N. Logan Street P. 0. Box 30195 Lansing, Michigan 48909 Gerald Charnoff, Esquire Shaw, Pittman, Potts and Trowbridge 2300 N Street, N. W.