ML18064A112

From kanterella
Jump to navigation Jump to search

Enclosure 1: Certificate of Compliance (Revision No. 6 Certificate of Compliance No. 9289, for the Model No. WE-1 Transportation Package)
ML18064A112
Person / Time
Site: 07109289
Issue date: 03/01/2018
From: John Mckirgan
Spent Fuel Licensing Branch
To: Travis Tate
Framatome
Devaser N
Shared Package
ML18064A111 List:
References
EPID L-2018-LLA-0024
Download: ML18064A112 (5)


Text

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9289 6

71-9289 USA/9289/B(U)F-85 1

OF 5

2.

PREAMBLE a.

This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.

b.

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3.

THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION

a.

ISSUED TO (Name and Address) b.

TITLE AND IDENTIFICATION OF REPORT OR APPLICATION Framatome Inc.

2101 Horn Rapids Road, Richland, WA 99354 Framatome Cogema Fuels application dated May 1, 2002, as supplemented.

4.

CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.

5.

(a)

Packaging (1)

Model No.: WE-1 (2)

Description A fresh fuel assembly shipping container. The package has two shipping configurations: one for shipping a single BW 17x17 fuel assembly composed of uranium dioxide pellets within zircalloy cladding; and the other for shipping up to 48 Pathfinder fuel assemblies within a steel canister which functions as a secondary containment vessel. The package consists of a cylindrical outer container and a rectangular inner container bolted to a strongback. The outer container is constructed of 11 gauge carbon steel and opens into two semi-cylindrical halves.

The inner container is comprised of 1-inch thick carbon steel plates that are bolted together.

The inner container is secured to the strongback by bolts and clamp arms. Wood blocks surround the region between the inner container and the strongback. The strongback is supported by 14 shock mounts attached to the outer container.

For BW 17x17 Fuel Shipment Configuration:

The BW 17x17 fuel assembly shipment configuration consists of the fuel assembly placed into the inner container. The fuel assembly is surrounded by thermal insulation and secured inside the inner container with nine integral clamp frames.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9289 6

71-9289 USA/9289/B(U)F-85 2

OF 5

5.

(2)

Description (Continued)

For Pathfinder Fuel Shipment Configuration:

Pathfinder Fuel shipment configuration consists of the Pathfinder fuel in the Pathfinder Canister, which is placed into the inner container. The Pathfinder Canister is a sealed cylindrical canister which houses up to 48 Pathfinder fuel assemblies. Wood dunnage or empty sheaths may be used to fill empty spaces in the canister. The canister is made of austenitic stainless steel and has a welded body and a bolted closure lid. The Pathfinder Canister is surrounded by thermal insulation, and secured inside the inner container with five integral clamp frames. The clamp frames, which consist of bolted clamp arms, are bolted to the inner rectangular container. Wood blocks surround both ends of the Pathfinder Canister. A stainless steel spacer tube is used to fill the space between the Pathfinder Canister and the inner container.

The approximate dimensions and weights of the package are as follows:

Inner container length 165 inches Inner container width (sq) 16 1/2 inches Outer container length 216 inches Outer container diameter 44 inches Maximum content weight 1610 pounds Maximum package weight (including contents) 9090 pounds (3)

Drawings The packaging is constructed in accordance with the following Framatome Cogema Fuels Drawing Nos.:

1273964, Rev. 0 1273965, Rev. 1 1273966, Rev. 0 1273967, Rev. 0 1273968, Rev. 0 The Pathfinder Canister Configuration is constructed in accordance with the following Framatome ANP Drawing Nos.:

5016270, Rev. 1 5021426, Sheets 1 and 2, Rev. 0.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9289 6

71-9289 USA/9289/B(U)F-85 3

OF 5

(b)

Contents (1)

Type and form of material (i)

For BW 17x17 Fuel Shipment Configuration:

A fuel assembly composed of uranium dioxide pellets within zircalloy cladding. The fuel assembly has the following specifications:

Assembly type BW 17x17 No. fuel rods 264 No. non-fuel tubes 25 Nominal fuel rod pitch, in.

0.496 Maximum fuel pellet OD, in.

0.3232 Nominal clad OD, in.

0.374 Nominal clad thickness, in.

0.022 Nominal guide and instrument tube OD, in.

0.48 Nominal guide and instrument tube ID, in.

0.452 Nominal active fuel length, in.

144 Maximum uranium enrichment, weight percent U-235 4.6 Maximum U-235 mass, kg 22.14 (ii)

For Pathfinder Fuel Shipment Configuration:

An unirradiated fuel assembly composed of six fuel pins clustered around a center absorber pin in a hexagonal pattern. The fuel pins consist of uranium dioxide pellets inside Incoloy 800 cladding. The absorber pin consists of Incoloy 800 cladding with or without poison material. Fuel pins and absorber pins are separated by spacer wires and enclosed in a cylindrical sheath made of stainless steel, incoloy or incoloy alloy.

The fuel assembly has the following specifications:

Assembly type Pathfinder No. fuel pins per assembly 6

No. non-fuel pins per assembly 1

Maximum uranium enrichment, weight percent U-235 7.51 Maximum uranium mass per assembly, kg U 2.2281

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9289 6

71-9289 USA/9289/B(U)F-85 4

OF 5

5.

(b)

Contents (continued)

Maximum UO2 density, g/cm3 10.61 Fuel pellet outer diameter (OD), in.

0.207 +/- 0.0005 Nominal active fuel length, in.

72.0 Minimum clad OD, in.

0.246 Maximum clad inner diameter (ID), in.

0.212 Nominal center-to-center pin pitch, in.

0.289 Nominal sheath ID, in.

0.945 Nominal sheath OD, in.

1.00 (2)

Maximum quantity of material per package (i)

For the contents described in Item 5(b)(1)(i):

One BW 17x17 fuel assembly contents, not to exceed 1610 pounds. The radioactive material may not exceed any of the following limits:

U-232 0.01 microgram per gram of uranium U-234 0.001 gram per gram of uranium U-236 0.013 gram per gram of uranium Tc-99 5 micrograms per gram of uranium Fission Products 4.4 x 105 MeV-Becquerel per kilogram of uranium Np and Pu 35 Becquerels per gram of uranium (ii)

For the contents described in Item 5(b)(1)(ii):

Up to 48 unirradiated Pathfinder fuel assemblies inside a Pathfinder Canister. The weight of the fully loaded canister not to exceed 800 pounds.

(c)

Criticality Safety Index (CSI):

100

6.

In addition to the requirements of Subpart G of 10 CFR Part 71:

(a)

The package shall be prepared for shipment and operated in accordance with the Operating Procedures of Chapter 7 of the application, as supplemented.

(b)

The packaging must meet the Acceptance Tests and Maintenance Program of Chapter 8 of the application, as supplemented.

7.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR §71.17.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9289 6

71-9289 USA/9289/B(U)F-85 5

OF 5

8.

Transport by air of fissile material is not authorized.

9.

Revision No. 4 of this certificate may be used until February 28, 2015.

10.

Expiration date: March 31, 2019.

REFERENCES Framatome ANP, Inc. application dated: May 1, 2002.

Supplement dated: November 12, 2002; January 8, 2004; January 23, 2009; and January 29, 2014.

Framatome Inc., name change request dated January 17, 2018.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

/RA/

John McKirgan, Chief Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Date: 03/01/18