ML18064A007
| ML18064A007 | |
| Person / Time | |
|---|---|
| Site: | 07109252 |
| Issue date: | 03/01/2018 |
| From: | John Mckirgan Spent Fuel Licensing Branch |
| To: | Travis Tate Framatome |
| Devaser N | |
| Shared Package | |
| ML18064A005 | List: |
| References | |
| EPID L-2018-LLA-0023 | |
| Download: ML18064A007 (3) | |
Text
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9252 9
OF 3
- 2.
PREAMBLE
- a. This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
b.
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3.
THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION
- a.
ISSUED TO (Name and Address)
2101 Horn Rapids Road, Richland, WA 99354 AREVA NP, Inc., consolidated application dated October 28, 2008, as supplemented.
- 4. CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.
- 5.
(a)
Packaging (1)
Model No.: 51032-2 (2)
Description A steel shipping container for fuel bundles, consisting of a strong-back and fuel bundle clamping assembly, shock mounted to a steel outer container. Nine separator blocks, which are 6" x 8" x 8-1/2" long and have a 3/8" thick wall and a rectangular gusset plate welded inside, are bolted between fuel bundles. The outer container is composed of an 11 gauge steel shell approximately 43" diameter by 216" long. The maximum weight of the package, including contents, is 7,500 pounds.
(3)
Drawings The packaging is constructed and assembled in accordance with the following AREVA NP Inc. Drawing Nos.: 02-1215926C-002; 02-1215929D-003; 02-1215930D-003; 02-1215931D-003; 02-1215932D-003; 02-1215933D-003; 02-1215934C-002; 02-1215935D-003; 02-1216010D-001.
5.(b)
Contents
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9252 9
OF 3
(1)
Type and form of material Unirradiated fuel assemblies, composed of uranium dioxide fuel pellets clad in zircaloy tubes. The fuel assemblies have the following parameters:
Fuel Rod Array 15x15 17x17 16x16 Assembly Type 1
MkB HTP 2
Adv W HTP 1
Adv W HTP 2
MKC CE 16 Long Nominal Fuel Rod Pitch, in 0.568 0.563 0.496 0.502 0.506 Number of Fuel Rods 208 204 264 264 236 Maximum Enrichment, wt%
235U 4.8 4.8 4.8 4.8 5.0 Maximum Pellet Density,
%TD 97.5 97.5 97.5 97.5 97.5 Minimum Pellet Outer Diameter, in 0.3693 0.3668 0.3218 0.3238 0.3245 Minimum Clad Outer Diameter, in 0.428 0.422 0.372 0.377 0.38 Minimum Clad Wall Thickness, in 0.023 0.023 0.0205 0.022 0.0238 Number of Guide Tubes 16 20 24 24 4
Minimum Guide Tube Outer Diameter, in 0.528 0.542 0.478 0.472 Minimum Guide Tube Wall Thickness, in 0.014 0.0145 0.013 0.02 Number of Instrument Tubes 1
1 1
1 1
Minimum Instrument Outer Diameter, in 0.491 0.542 0.478 0.472 Minimum Instrument Wall Thickness, in 0.024 0.0145 0.013 0.02 Clad/Tube Material Type Zr Alloy Zr Alloy Zr Alloy Zr Alloy Zr Alloy Maximum Active Fuel Length, in 144 144 144 144 196 (2)
Maximum quantity of material per package Two fuel assemblies. Total weight of fuel assemblies, including control rod assemblies, not to exceed 3300 pounds.
Maximum quantity of radioactive material within a package may not exceed a Type A quantity.
5.(c)
Criticality Safety Index (CSI): 1.0
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9252 9
OF 3
- 6.
Each fuel assembly must be unsheathed or must be enclosed in an unsealed polyethylene sheath which will not extend beyond the ends of the fuel assemblies. The ends of the sheaths must not be folded or taped in any manner that would prevent the flow of liquids into or out of the sheathed fuel assemblies.
- 7.
Hydrogenous shims are not permitted within the fuel assemblies.
- 8.
In addition to the requirements of Subpart G of 10 CFR Part 71:
(a)
The package shall be prepared for shipment and operated in accordance with Chapter 7.0 of the application.
(b)
Each packaging shall be maintained in accordance with Section 8.2 of the application.
(c)
Each packaging shall meet the acceptance tests in Section 8.1 of the application.
- 9.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.17.
- 10.
Transport by air of fissile material is not authorized.
- 11.
Revision No. 7 of this certificate may be used until November 30, 2014.
- 12.
Expiration date: October 31, 2018.
REFERENCES AREVA NP Inc. consolidated application dated October 28, 2008.
Supplement dated: November 4, 2008; July 7, 2009; September 19, and December 18, 2013.
Framatome Inc., name change request dated January 17, 2018.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
/RA/
John McKirgan, Chief Licensing Branch Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Date: 03/01/18