Advises That 900928 Response to Generic Ltr 90-03 Re Vendor Interface for safety-related Components Acceptable
ML18057A571
Person / Time
Site: Palisades Entergy icon.png
Issue date: 11/15/1990
From: Brian Holian
Office of Nuclear Reactor Regulation
To: Slade G
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
GL-83-28, GL-90-03, GL-90-3, TAC-76269, NUDOCS 9011190221
Download: ML18057A571 (3)


Text

Docket No. 50-255 Mr. Gerald B. Slade Plant General Manager Palisades Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043

Dear Mr. Slade:

Nov6!1ber 15, 1990

SUBJECT:

RESPONSE TO BULLETIN 90-03 FOR PALISADES (TAC NO. 76269)

On March 20i 1990 9 the NRC issued Generic Letter (GL) 90-03 11 Relaxation of Staff Position in Generic Letter 83-28, Item 2.2 Part 2 'Vendor Interface for Safety-Re 1 ated Components. 111 The GL requested that a 11 1 i censees and applicants review their present vendor interface programs and modify them as necessary using thE* guidance suppl*ied in the GL.

By 1e:tter dated September 28 9 1990, you responded to Generic Letter 90-03 and indicated that the Palisades vendor interface programs have been reviewed.

Your review confirmed that the elements and expectations established in Generic.

Letter 90-03 have been addressed at Palisades 9 and no further actions have been identified. The staff has reviewed your response and finds it acceptable.

This action closes TAC No. 76269.

cc:

See next page

/

/... ~,,.*

DISTRI~~JlON/

DOCKET FILE NRC & LOCAL PDRs PD31 RIF JZ\\~OLINSKI SMEADOR LJl./PD31 :y SMEADOR 111,'Jl90 OGC EJORDAN ACRS(lO)

DLABARGE BHOLIAN Sincerely, Isl Brian E. Holian, Project Manager Project Directorate III-1 Division of Reactor Projects - Ills IVs V & Special Projects Office of Nuclear Reactor Regulation PMIPD31:DRSP BHOLIJl.N --efti).._

111\\1\\ 190 D/PD31 :DRY/1' <;)Ip p t I RPIERSON

/

/i ~

{X jj 11lit;l90

~f D { y PALISADES RESPONSE TO 90-03 I~

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Docket No. 50-255 Mr. Gerald B. Slade Plant General Manager Palisades Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043

Dear Mr. Slade:

Novamer 15, 1990

SUBJECT:

RESPONSE TO BULLETIN 90-03 FOR PALISADES (TAC NO. 76269)

On March 20, 1990, the NRC issued Generic Letter (GL) 90-03 "Relaxation of Staff Position in Generic Letter 83-28, Item 2.2 Part 2 'Vendor Interface for SafEty-*Related Components."' The GL requested that all licensees and applicants review their preserit vendor interface programs and rr:odify them as necessary using the guidance supplied in the GL.

By letter dated September 28, 1990, you responded to Generic Letter 90-03 and indicated that the Palisades vendor interface progra~s have been reviewed.

Your review confirmed that the elements and expectations established in Generic Letter 90-03 have been addressed at Palisades, and no further actions have been idt~tifi~d. The staff has reviewed your response and finds it acceptable.

This actic~ closes TAC No. 76269.

cc:

See next page Sincerely, Brian E. Holian, Project Manager Project Directorate III-1 Division of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation

Mr. ~erald E. Slade Consurners Po\\f;er Company cc:

M. I. Miller, Esquire Sidley & Austin 54th Floor One First Natior1al Plaza Chicago, Illinois 60603 Mr. Thomas A. McNish, Secretary Consu~ers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Corr.par:y 212 West Michigan Avenue Jackson, Michigan 49201

  • Regional AC:n1iriistrator, Region III U.S. Nuclear Regulatory Corm;issicr1 799 Rcosevelt Road Glen Ellyn, Illinois 60137 l1E:rry Sarno Tow~ship Sup~rvisor CovE:rt Township 36197 M-140 Highway Covert, MiLhigan 49043 Office uf the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Mr. David J. Vande~alle Director, Safety and Licensing Palisades Plant 27780 Blue Star Memorial Hwy.

Covert, Michigan 49043 Resident Inspector c/o U.S. Nuclear Regulatory Cornmissior1 Palisades Plant 27782 Blue Star Memorial Hwy.

Covert, Michigan 49043 Paliscides Plant Nuclear Facilities and Environmental Monitoring Sectiorr Office Division of Radiological Health P.O. Box 30035 Lansing, Michigan 48909 Gerald Charnoff, P.C.

Shaw, Pittman, Potts &

Trowbridge 2300 N. Street, N.W.

Washington, D.C.

20037 Mr. David L. Brannen Vice President Pelisades Generating Plant c/o Bechtel Po~er Corporatio~

15740 Shady Grove RcaC:

Gaithersburg, Mary lar.d 20877