ML18057A332

From kanterella
Jump to navigation Jump to search
Proposed Tech Specs Re Overpressure Protection Sys
ML18057A332
Person / Time
Site: Palisades 
Issue date: 07/11/1990
From:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Shared Package
ML18057A330 List:
References
NUDOCS 9007170158
Download: ML18057A332 (4)


Text

ATTACHMENT 1 Consumers Power Company Palisades Plant Docket 50-255 Proposed Technical Specification Page July 11, 1990 1 Page L

~~~-_,;:;: __,_ ___ _.!; ____ --"='--

{

9007170158 900711 1

PDR ADOCI< 05000255

(

p PDC

..., -- _.,, ______ +----

~---r +/-. f;

'r-r

..., \\

e 4.1 INSTRUMENTATION AND CONTROL Applicability Applies to the reactor protective system and other critical instrumentation and controls.

Objective To specify the minimum frequency and type of surveillance to be applied to critical plant instrumentation and controls.

Specifications Calibration, testing, and checking of instrument channels, reactor protective system and engineered safeguards system logic channels and miscellaneous instrument systems and controls shall be performed as specified in 4.1.1 and in Tables 4.1.1 to 4.1.3.

4.1.1 Overpressure Protection Systems

a. Each PROV shall be demonstrated operable by:
1.

Performance of a channel functional test on the PORV actuation channel, but excluding valve operation, within 31 days prior to entering a condition in which the PORV is required operable and at least once per 31 days thereafter when the PORV is required operable.

2.

Performance of a channel calibration on the PORV actuation channel at least once per 18 months.

3.

Verifying the PORV isolation valve is open at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> when the PORV is being used for overpressure protection.

4.

Testing in accordance with the Inservice Inspection requirements for Section XI, Subsection IWV, for Category B valves.

4-le Amendment No.

11~

TSP0790-0051-NL04 I

I I

ATTACHMENT 2 Consumers Power Company Palisades Plant Docket 50-255 Marked Up Technical Specification Page July 11, 1990 1 Page

. *~

4~1 4.1. l INSTRUMENTATION AND CONTROi.

Applicability

'Applies to the reactor protective. system and other critical ins.trumentation and controls.

Objective To specify the minimum frequency and type of surveillance to be applied to criti.cal plant instrumentation and controls *.

Specifications Calibration, testing, and checking of instrument channels, reactor protective system and engineered safeguards system logic channels and miscellaneous instrument.systems and controls shall be performed as specified in 4.1.1 and in Tables 4*. 1. l to 4. 1. 3

  • Overpressure Protection Systems
a.

Each PROV shall be demonstrated operable by:

1.

Performance of a channel functional test on the PORV actuation channel, but excluding valve operation, within 31 days prior to entering a condition in which the PORV is required operable and at least once per 31.days thereafter when the PORV is required operable.

2.

Performance.of *a channel calibration on the PORV actuation channel at least once per 18 months.

3.

Verifying the PORV iso.lation valve. is open at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> when the PORV is being used for overpressure protection.

4-.

Testing in accordance with the ins.ervice inspection requirements for ASME Section XI>> Section IWV Category C valves.

1

'L~ pec:..J-u.....

Tes*L") ;"' a...c.c..erdo..,,,,c.c we~ fhe. i.~~e"u'c.e fe~~l("C!ke_~{s ~r. Sec+.tc~ ll, Sl4..6~hM r l0 v,.(:("

Co...1e5o'"1 i l)cLLJeS.

4-le Amendment No. 130 March 23, 19.90 TSP0588-0025-NL02-NL04