May 2, 1990 Docket No. 50-255 Serial No. PAL-90-028 Mr. Kenneth W. Berry Director, Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201
Dear Mr. Berry:
DISTRIBUTION Docket l'11e NRC & Local PDRs PD31 Reading JZwolinski MRShuttleworth ADeAgazio OGG EJordan ACRS(lO)
TRoss
SUBJECT:
CONSUMERS POWER COMPANY CONFIRMATION RELATED TO ACTIONS REQUIRED BY NRC GENERIC LETTER 89-10 (MPA B-110)
By letter dated December 20, 1989, Consumers Power Company (CPCo) responded to NRC Generic Letter 89-10 related to motor-operated valve testing and surveillance~ In that response, CPCo indicated that the Palisades Plant will comply with the schedule and recommendations set forth in Generic Letter 89-10.
Your letter constitutes confirmation of your commitment to implement the actions as requested. Therefore, this action item considered complete.
Revie\\-J and verification of program implementation wi 11 be addressed by the regional inspection process.
cc:
See next page PM/ PD31 rJll,rY ADeAgazio y !JIJ90 CfJ (J fJ (A)D/PD3l:DRSP DDiianni (j) 'f I )CJ /90 Sincerely,
~i_nal signed by Albert W. De Agazio, Sr. Project Manager Project Directorate III-1 Division of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation
)
\\
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Docket No. 50-255 Serial No. PAL-90-028 Mr. Kenneth W. Berry Director, Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson~ Michigan 49201
Dear Mr. Berry:
May 2, 1990
SUBJECT:
CONSUMERS POWER COMPANY CONFIRMATION RELATED TO ACTIONS REQUIRED BY NRC GENERIC LETTER 89-10 (MPA B-110)
By letter dated December 20, 1989, Consumers Power Company (CPCo) responded to NRC Generic Letter 89-10 related to motor-operated valve testing and surveillance.
In that response, CPCo indicated that the Palisades Plant will comply with the schedule an~ recommendations set forth in Generic Letter 89-10.
Your letter constitutes confirmation of your commitment to implement the actions as requested. Therefore, this action item considered complete.
Review and verification of program implementation will be addressed by the regional inspection process.
cc: See next page Sincerely,
~~.sr.
Project Directorate III-1 Division of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation
' I,_,
Mr. Kenneth W. Berry Consumers Power Company cc:
M. I. Miller, Esquire Sidley & Austin 54th Floor One First National Plaza Chicago, Illinois 60603 Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Conrnission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Jerry Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Mr. Gerald B. Slade Plant General Manager Palisades Plant 27780 Blue Star Memorial Hwy.
Covert, Michigan 49043 Resident Inspector c/o U.S. Nuclear Regulatory Corrmission Palisades Plant 27782 Blue Star Memorial Hwy.
Covert, Michigan 49043 Palisades Plant Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health P.O. Box 30035 Lansing, Michigan 48909