Monthly Operating Rept for June 1989 for Palisades Nuclear Plant
ML18054A834
Person / Time
Site: Palisades Entergy icon.png
Issue date: 06/30/1989
From: Goralski G, Mlynarek M
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 8907130248
Download: ML18054A834 (4)


Text

C~ITTlS~~~IHBl~~

!Pl~wer l'DWERINli ft/llCHlliAN'S l'ROliRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 July 3, 1989 US Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 LICENSEE REPORT OF MONTHLY OPERATING DATA DPR-20, DOCKET NO 50-255 Enclosed is a copy of the Monthly Operating Data and a Summary of Operating Experience for the Palisades Nuclear Plant for the month of June, 1989.

George Goralski Reactor Engineer CC: DPHoffman, P26-117B KMHaas, Palisades ABDavis, USNRC KWBerry/RRFrisch, P24-614B CSKozup, Palisades Resident Inspector, Palisades DLHackett, Pll-4208 DRHahn, Div of Rad Health Services, Lansing, MI SLHall, Michigan Dept of Labor, Lansing, MI RCallen, Michigan Public Service Commission Records Center, INPO, Atlanta, GA RWTaylor, CE, Palisades AAAlatalo, Palisades LLBumb, P21-135 GBSzczotka, P-21-135A HRSnider, P-21-129 Administrator, USNRC Document Control, 950*22*35*10/L MGM89*018 OC0185-0001A-OP03 A CMS ENERGY COMPANY

OPERATING DATA REPORT DOCKET NO 50-255 DATE 07-03-89 COMPLETED BY MGMlynarek TELEPHONE (616)764-8913 OPERATING STATUS NOTES

1.

Unit Name: Palisades


~

2.

Reporting Period:

890601-890630

3.

Licensed Thermal Power (MWt):

2530

4.

Nameplate Rating (Gross MWe):

811.7

5.

Design Electrical Rating (Net MWe):

805

6.

Maximum Dependable Capacity (Gross MWe): -k-k770

7.

Maximum Dependable Capacity (Net MWe):

~'*730

8.

If Changes Occur in Capacity Ratings (Items Number 3 through 7) since last report, give reasons:

9.

Power Level to Which Restricted, if any (Net MWe):

623 (80%)

10.

Reasons for Restrictions, if any:

80% power limitation implemented based upon administrative guidelines with intent to improve steam generator reliability (not

11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.

based upon regulatory requirements).

Hours In Reporting Period Number of Hours Reactor Was Critical Reactor Reserve Shutdown Hours Hours Generator On-Line Unit Reserve Shutdown Hours This Month 720.0 720.0 720.0 Yr-to-Date 4,343.0 3,627.9 3,611.0 Gross Thermal Energy Generated (MWH) 1,457,664 7,255,584 Gross Electrical Energy Generated (MWH) 467,760 2,343,710 Net Electrical Energy Generated (MWH) 439,149 2,199,436 Unit Service Factor 100.0 83.1 Unit Availability Factor 100.0 83.1 Unit Capacity Factor (Using MDC Net) 83.6 69.4 Unit Capacity Factor (Using DER Net) 75.8 62.9 Unit Forced Outage Rate 0.0 16.9 Cumulative 153,686.0 82,635.3 78,733.1 165,806,589 51,888,195 48,851,685 51.2 51.2

  • 48.7 39.5 34.4 Shutdowns Scheduled Over Next Six Months (Type, Date and Duration of Each):

45 day scheduled maintenance outage for steam generator repair to start October 1 1989.

If Shut Down at End of Report Period, Estimated Date of Start Up:

Units in Test Status (Prior to Commercial Operation):

INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

    • Based on condenser backpressure Forecast
  • Weighted Average (635 MWe used as MDC Net prior to October 1985)

Achieved OC0185-0001B-OP03

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO 50-255 UNIT Palisades DATE 07-03-89 COMPLETED BY MGMlynarek TELEPHONE (616)764-8913 MONTH JUNE 1989 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 606 17 616 2

616 18 609 3

611 19 I 608 4

613 20 609 5

612 21 609 6

609 22 602 7

607 23 600 8

605 24 616 9

610 25 593 10 615 26 602 11 615 27 602 12 614 28 607 13 615 29 614 14 615 30 612 15 619 16 618 INSTRUCTIONS:

On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

OC0185-0001C-OP03

SUMMARY

OF OPERATING EXPERIENCE FOR JUNE, 1989 Power was maintained at 80% for the entire month of the June at Palisades.

OC0185-0001E-OP03