Part 21 Rept Re Failure of Ashcroft Glycerin Filled Bourdon Tube Pressure Gauges That Failed at Pressure within Operating Range.Caused by Separated Weld.Faulty Gauges Replaced
ML18054A307
Person / Time
Site: Palisades 
Issue date: 05/25/1988
From: Berry K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Office of Nuclear Reactor Regulation
References
REF-PT21-88-059-000 PT21-88-059-000, PT21-88-59, NUDOCS 8806010295
Download: ML18054A307 (1)


Text

,..

L' consumers Power POWERIN&

MICHlliAN"S PROliRESS General Offices:

1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-1636 May 25, 1988 Director Nuclear Reactor Regulator Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

10CFR PART 21 REPORT - ASHCROFT PRESSURE GAUGE Kenneth W Berry Director Nuclear Licensing Consumers Power Company provides this written follow-up notification of the failure of three Ashcroft glycerin filled bourdon tube pressure gauges that failed at pressure within their operating range.

The three gauges were located on the diesel generator secondary fuel oil filter.

All have the same identification stamp on the back of the gauge.

The stamping is a circled 7, a circled Qll, followed by XS.

The bourdon tubes on two of the gauges were found with a separated weld.

The third bourdon tube separated from the sensing port.

The gauges were supplied from Dresser Industries Instrument Division, 250 E Main Street, Stratford, Connecticut.

The gauges are 0-100 psig type 1009 Duralife pressure gauges.

Verbal notification was provided to Mr Bruce Burgess, USNRC Region III on May 23, 1988.

Corrective action has been to replace the faulty gauges.

Further corrective action will be to locate and replace all gauges, with the same identification stamp, by July 1, 1988.

No further advice is suggested at this time.

The responsible individual for corrective action is Mr M D King, Mechanical System Engineering Section Supervisor.

Kenneth W Berry Director, Nuclear Licensing CC Administrator, Region III, NRC NRC Resident Inspector - Palisades OC0588-0020A-NL02

\\