ML18053A370

From kanterella
Jump to navigation Jump to search
Provides Confirmation That Required Procedures Re Generic Ltr 88-03 Concerning Generic Issue 93, Steam Binding of Auxiliary Feedwater Pumps, in Place & Will Be Maintained
ML18053A370
Person / Time
Site: Palisades 
Issue date: 05/09/1988
From: Kuemin J
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
TASK-093, TASK-93, TASK-OR GL-88-03, GL-88-3, NUDOCS 8805120272
Download: ML18053A370 (6)


Text

.

I, consumers Power l'OWERINli NllCHlliAN'S l'ROliRESS General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-0550 May 9, 1988 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

STEAM BINDING OF AUXILIARY FEEDWATER PUMPS - RESPONSE TO GENERIC LETTER 88-03 Generic Letter 88-03 concerning the resolution of Generic Issue 93, "Steam Binding of Auxiliary Feedwater Pumps" required Licensees to confirm that certain procedures are in place and will be maintained.

In particular, it r~quired that the Licensee should:

J. Maintain procedures to monitor fluid conditions within the AFW system each shift during times when the system is required to be operable.

This monitoring should ensure that fluid temperature at the AFW pump discharge is maintained at about ambient levels.

2.

Maintain procedures for recognizing steam binding and for restoring the AFW system to operable status, should steam binding occur.

As stated in our response to IE Bulletin 85-01 dated February 26, 1986, the requirement to monitor the Auxiliary Feedwater piping is a part of our Auxiliary Building Data Sheet (Primary).

This data sheet is completed by the Auxiliary Operator each shift and is reviewed and initialed by the shift Supervisor.

In addition, Attachment 2, Part III (system testing) to the Feedwater System Operating Procedure (SOP 12) specifies testing for check valve back leakage.

This part includes guidelines for restoring the AFW system should high pump temperatures occur.

By this letter, Consumers Power Company provides confirmation that the required procedures are in place and will be maintained.

OC0488-0116-NL02 8805120272 8:30509 PDR ADOCK 05000255 P

DCD

I'\\, Steam Binding of Auxiliary Feedwater Pumps -

Response to Generic Letter 88-03 May 9, 1988 3

A copy of the current data sheet and the pertinent page for SOP 12 *is attached.

/.~

L Kuemin Licensing Engineer CC Administrator, Region III, NRC NRC Resident Inspector - Palisades Attachment OC0488-0116-NL02

CONSUMERS POWER COMPANY Palisades Plant Docket 50-255 License DPR-20 Response to Generic Letter No 88-03 Dated February 17, 1988 At the request of the Commission and pursuant to the Atomic Energy Act of 1954 and the Energy Reorganization Act of 1974, as amended, and the Commission's Rules and Regulations thereunder, Consumers Power Company submits our response to NRC letter dated February 17, 1988, entitled,"Resolution of Generic Safety Issue 93, "Steam Binding of Auxiliary Feedwater Pumps (Generic Letter 88-03)."

Consumers Power Company's response is dated May 9, 1988.

CONSUMERS POWER COMPANY David P Hoffman, Nuclear Operations Sworn and subscribed to before me this 9th day of May 1988.

E Buehrer No ary Public Jackson County, Michigan My commission expires October 31, 1989 OA0488-0116-NL02

OPERATOR'S INI flALS 11*10 Hill EQUIPMENT ROOM F-54A PURIFICATION FILTER AP dPl-0204

(< 15 P51)

F-54B PURIFICATION Fil TER AP dPl-0205

(< 15 PSll WGDT T-101APRESSURE PIA-1160

(< 100 PS1G)

WGDT T-101B PRESSURE

.PIA-1161

(< 100 PSIG)

WGDT T-101C PRESSURE PIA-1162

(< 100 P51G)

WEST SAFEGUARDS SUMP'ROOM LEI/EL ll-10078 (2-15%)

EAST SAFEGUARDS SUMP1ROOM LEllEL Ll-11108 (2* 15~*l C-33 PANEL SECURE (2 LOCIC.S)

WASTE GAS SURGE TANI( PRESSURE PIA-1111 (14* 1 5 PSIA)

WGDT T*68A PRESSURE PIA-1119

(< 100 PSIG)

WGDT T-68B PRESSURE PIA-1120

(< 100 PS1Gl WGDT T-68C PRESSURE PIA-1121

(< 100 PSIG)

WASTE GAS DECAY TANK IN SERll1CE SOUTH LAUNDRY DRAIN TANK LEVEL LIA*l 124 (20* 75~o)

NORTH LAUNDRY DRAIN TANK LE\\/El LIA-1127 (20*7S%)

WEST DIRTY WASTE TANK LEVEL LIA-1115 (20-92%)

EAST DIRTY WASTE TANK LEVEL LIA* 1117

{20-92.,.l NORTH FILTERED WASTE TANK LEVEL LIA* 11 30

-(0-88'+-ii)

SOUTH Fil TE RED WAS TE TANK LEVEL LIA* 1133 (0-88~)

Fil TERED WASTE TANK IN SERlll(E PRIMARY SYSTEM DRAIN TANK PRESSURE PIA-100'1 (0-S PS1G)

PRIMARY SYSTEM DRAIN TANI( LEI/El LIA-1001 (20-90~*.)

VACUUM DEGAS1F1ER TANK LEI/EL LI(* 1061 (40-60%)

VACUUM DE GA SI FIE RT ANI( PRESSURE Pl-1004 (3*10PSIA)

VACUUM DEGAS1F1EA PUMP DISCH Pl* 1005 (65*90 PSIG)

CLEAN WASTE ACVR TANI< PRESSURE PIA-1065

(<lPSIG)

'A' CLEAN WASTE AC\\/A TANK LEVEL llA-1012

(<95"'i.l

'B' CLEAN WASTE ACllA TANK LEVEL LIA-1014

(<95~**>

  • c CLE AN WAS TE AC11A T ANIC LEVEL LIA-1016

(<95~.)

'D' CLEAN WASTE. RCVA TANK LEllEL LIA-1018

(<95%)

CLEAN WASTE ACVA TANK IN SERVICE NORTH CHEM DRAIN TANK LEVEL LIA-1006 (20*80~**)

SOUTH CHEM DRAIN TANK LEVEL LIA-1007 (20-80,.)

FUEL POOL DEMIN

. p dPIA 0924

(< 30 PSI)

CONSUMERS POWER COMPANY

.ILIARY BUILDING DATA SHEET e (Primary)

A B

c E~UIPMENT DRAIN TANK LEI/EL LI *1008 (20 90~.)

~* :~

NORTH TREATED WASTE TANK LEI/EL

(....

LIA*1046 (0-90%)

SOUTH TREATED WASTE TANIC LEI/EL LIA* 1048 (0*90~o) 1ND1CATED DILUTION FLOW FR-1050 C-161 GAS BOTTLES (3)

(>200 PSIG)

STATION 5 BOTTLE PRESSURE Pl-22 79A

( ~ 2000 PSIG)

STATIONS HEADER PRESSURE Pl-2279B (80-90 PSIG)

'A' CCW HEAT EXC11

~p dPl-0918

(< 1 7 PSI)

'B' CCW HEAT EXCH 6P dPl-0919

(< 17 PSI)

~

y T T

.,,. 1J

  • c* AFW DISCH PIPING TO B SIG CCW TtMPtlUlTV"E TIC-OB21 (74-90° f) r

"(

_y)

A&B AFW PIPING TO B SIG l

A&B AFW PIPING TO A S1G I

\\ 'C' AFW PIPING TO A StG STATI'QN 1 BOTTLE PJftSSURE P1-2273A

( ~ 2000 PSIG)

STATION 1 HEADER PRESSURE Pl-2 2 738 (60* 70 PSIG)

ST A TION 1 A BOTTLE PRE SS URE Pl-2280A

( ~ 2000 PSIG)

STATION lA HEADER PRESSURE P1*2280B (80*90 PSIGl SIRW TANK RECIRC TEMPERATURE n-0371

<45-100* Fl SPENT FUEL POOL PUMPIHX ROOM TREATED WASTE EQUIPMENT ROOM

'8' BORIC ACID STOR TANK TEMPERATURE TIC-0206 (158-16S°Fl

'B' BORIC ACID STOA TANK TEMPERATURE TIC-0207 (lSB-165° F)

'A' BORIC ACID STOA TANK TEMPERATURE TIC-0208

{158-165* Fl

'A' BORIC ACID STOA TANIC: TEMPERATURE TIC-0209 (158*165° F)

PURIFICATION DE MIN

~p dPl-0203

(< 15 PSI)

C* 162 GAS BOTTLES (3)

( >200 PS1Gl CWRT~ESIN PUMP ROOM

'A' CHARGING PUMP OIL PRESSURE Pl-0217A

(> 20 PSIG)

  • 9* CHARGING PUMP OIL PRESSURE Pl-021 78

(>20 PSIG}

'C Ct1AAGING PUMP OIL PRESSURE I

Pl-02 17(

( > 20 PSIG)

'A' CHARGING PUMP SEAL LEAKAGE

( < 500 ML/MIN)

'B' CHARGING PUMP SEAL LEAKAGE

( < 200 ML/MIN)

  • c* CHARGING PUMP SEAL LEAKAGE

(<200 ML'MIN)

PRIMARY SYSTEM DRAIN TANK PUMP ROOM S112W TAN< i.JOZ. Z.1.£ 1..~ICA<.~.. ~"

  • PIPING SHOULD BE COOL TO TOUCH. SIGNIFYING NO BA.CK LEAKAGE FROM THE STEAM GENERATORS

~,., I I 8 I A

B c

I I

~
T.r i

l I

I I

I I

I

--r-.. -----j H~i~ +;;;,?;w~

I I

I I

l I i I

I

WG COMPRESSOR ROOM LAUNDRY TANK ROOM C-54 WG COMPRESSOR ROOM BAMIX TANK STATUS BA EYE WASH STATION FLUSH AUX BUILDING CHILLER & HN ROOM FUEL POOL TEMPERATURE TIA-0925 FUEL POOL LEVEL LOCAL VISUAL SFP GATE N2 PRESSURE Pl 2252 (80-110°F)

{2*8" <SKIM)

{ ~ 10PS1G)

SFP AREA SAFETY CHAINS IN PLACE SFP VENT & MCC ROOM V-8A&B VENT EQUIPMENT ROOM CV-3029 HP AIR Pl-30298 CV-3029 LP AIR Pl-3029A CV-3057 HP AIR Pt-30578 CV-3057 LP AIR Pl-3057A EAST SAFEGUARD HP AIR Pl-0439

  • {170-175PSIG)

(55-65 PS1G)

{ 170-1 75 PSIG)

(55-65 PSIG)

(300-325 PSIG)

A B

c CV-3031 HP AIR Pl-30318 CV-3031 LP AIR P1-J031A CV-3030 HP AIR Pl-30308 CV-3030 LP AIR Pl-3030A WEST SAFEGUARD HP AIR Pt-0441

( 170-1 75 PSIG)

(55-65 PS1G)

( 1 70-1 75 PSIG)

(55-65 PSIG)

(300-325 PSIG)

CONTAINMENT SAFETY CHAINS CONTAINMENT TOUR IF REACTOR HEAD REMOVED*

CHECK FOR LOOSE MA TE RIAL SUPERVISOR"S REVIEW COMMENTS A

NOTE: Out-of-specification readings are to be circled in red ink, and a brief explanation concerning the problem provided in the Comments Section.

SYSTEM TESTING

?roe No SOP 12 Revision 12 Page 2 of 2

3.

Stop the **K-7A; **K-78 auxiliary oil pump by turning its Local hand switch (Panel '"'EC-24; *EC-25) from "auto" to "off" to "auto."

III.

TEST FOR CHECKVALVE BACKLEAKAGE

l. Verify, by carefully touching the AFW piping near each flow control valve, that there is no backleakage from the steam generators.

(If the piping is cool to the touch, significant backleakage does not exist.)

2. If the AFW piping is hot to the couch, take the following actions:

2.1 Notify Control Operator and Shift Supervisor.

2.2 Check temperature of the associated AFW pump(s).

2.3 Start an AFW pump and flush the hot portions of the AFW piping to the steam generator(s).

2.4 Monitor piping and pump temperatures for reoccurrence of backleakage.

2.S If an AFW pump is found too hot to touch (Step 2.2) or if high piping temperatures reoccur a Work Request/Work Order, to repair the leaking valves at the next shutdown, should be issued.

2.6 If backleakage is sufficient to cause high pump temperatures, isolation of the leakage path with one of the FOGG valves should be considered.

(Backleakage has actually disabled AFW pumps by steam-binding at other nuclear plants.)

With the backleakage path isolated, the pump and local discharge piping should be vented to refill the pump with cool condensate.

The discharge piping should then be flushed to the steam generators and the FOGG valve reopened.

NOTE:

Isolating FOGG valve renders associated flow control valve inoperable and initiates a 72 hrs LCO; see Technical Specification 3.S.

pa0280-l043c-89-91