Text
c::
f Docket No. 50-255
. Mr. Kenneth W. Berry *
.Di rector, Nuclear l*i ce'ns i ng' Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201
Dear Mr.* Berry:
JUN 2 6.
- 1997.
--r
SUBJECT:
PALISADES PLANT - REACTOR TRIP~SYSTEM R~LIABILITY~ ITEMS 4.2.3 AND 4.2.4 OF GENERIC LETTER 83-28, SALEM ATWS EVENT (TAC NO. 53926)
We have reviewed your response to the subject items dated February 3, 1984;
- and agree with your position that the reliability concerns raised by these items regarding t.rip circuit breakers do not apply to Palisa.des where a-c contactors a~e used f9r this:function.
We, therefore, corisider these items closed.
. Distribution Docket File N*Rc PDR Local PDR G. Holahan R." Ingram *
- T. Wambach
- OGC-Bethesda
.E. Jordan J;.Partlow ACRS (10)
PD31 Plant Gray File cc:
Plant *service list t/'Y¥ LA:PD3l:DRSP RINGRAM N
~ IJ./87 PM:PD3l:DRSP TWAMBACH:dlm
? /~/87
!8707060516 870626 I
~DR ADOCK 05000255
\\
P PDR:
L...i....
i Sincerely~
Thomas V. Wambach, Project Manager
.Project Directorate III-1 Divisitin of Reactor Projects - III, IV, V and Special *Projects rv/.
ACTINGD:PD3l:DRSP MJVIRGILIO
~l?P/87
Mr. Kenneth W. Berry Consumers Power Company cc:
M. I. Miller, Esquire Isham, Lincoln & Beale Slst Floor Three First National Plaza Chicago, Illinois 60602 Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Jerry Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Palisades Plant ATTN:
Mr. David P. Hoffman Plant General Manager 27780 Blue Star Memorial Hwy.
Covert, ~ichigan 49043 Resident Inspector c/o U.S. Nuclear Regulatory Commission Palisades Plant 27782 Blue Star Memorial Hwy.
Covert, Michigan 49043 Palisades Plant Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health P.O. Box 30035 Lansing, Michigan 48909