Corrects 860710 Response to Open Item 1 from Insp Rept 50-255/86-11.Cs-137 Activity for Activity Detector 2 Should Read 5.8E-5 Uci/Ml (3)
ML18052A725
Person / Time
Site: Palisades 
Issue date: 09/26/1986
From: Johnson B
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 8610100535
Download: ML18052A725 (1)


Text

consumers Power POWERINli MICHlliAN'S PROliRESS General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-0550 September 26, 1986 James G Keppler, Administrator Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

RESPONSE TO INSPECTION REPORT 86-011 OPEN ITEM 50-255/86011-01, REVISION 1 Consumers Power Company letter dated July 10, 1986 responded to NRC Open Item 50-255/86011-01 by giving the results of the analysis of an unknown sample from the NRC.

During a review of the information submitted, an error in the reported activity of CS-137 for Activity Detector #2 was discovered.

This information should read CS-137 5.8E-5 uci/ml (3).

Brian D Johnson Staff Licensing Engineer CC Director, Office of Nuclear Reactor Regulation Director, Office of Inspection & Enforcement NRC Resident Inspector - Palisades OC0986-0161-NL02 ISEp 2 91986