  • Ji Docket No. 50-255 LSQ5..,85-05-005 Mr. David J. VandeWalle Director, Nuclear Licensing Consumers Power Company 1945 W. Parnall Road Jackson, Michigan 48071

Dear Mr. VandeWalle:

May 3, 1985

SUBJECT:

LOCA-ECCS ANALYSIS PERFORMED BY EXXON NUCLEAR Re: -

Palisades Plant Your letter dated March 27, 1985 responded to our telephone call on March 20, 1985 concerning problems identified with Exxon Nuclear LOCA-ECCS analysis of W~stinghouse plants for which Exxon provides reload fuel and supporting analyses. **You stated that the Exxon analyses for Palisades predate the introduttion of the multiplication factors and augmentation factqrs in the*

TOODEE2 computer code.

You also stated that the K factor was not employed in the analyses for Palisades but rather an axial ~hape sensitivity study was performed and was reported in Exxon report XN-NF 78-16.

This -was reviewed

_by the_ staff and accepted in approving the use* of Exxon fuel for reload.

On this basis we find that this issue is not applicable to Palisades Plant and consider* the matter closed.

Sincer~ly,

~~*l *isned by:

John A. Zwolinski, Chief Operating Reactors Branch #5 Division of Licensing

  • cc:

See next. page DISTR*IBLITION Docket NRC PDR Loca*1 PDR ORB #5 Reading HThompson OELD.

DL:ORB#5 w C,Jamerson * :b S' I;).. /85 BGrimes TWambach CJamerson

. JZwol inski ACRS (10)

EJordan

.~rw-DYORB#5 TWambach f I a/85 8505080358 850503 PDR ADOCK 05000255 P

PDR*

J ;J

  • J_

I

(' 1

~. * :. :_.J '

DS~S BS 5 :3 /85

~

DL:ORR#5 JZwolinski 5 I> /85

    • ~

Mr. David J. VandeWalle Consumers Power Company cc M. I. Miller, Esquire Isham, Lincoln & B~ale 51st Floor*

Three First National Plaza Chicago, Illinois 60602 Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michig~n A~e~~e Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator Palisades Plant Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health P. 0. Box 30035 Lansing, Michigan 48909 Nuclear Regulatory Commission, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 llerr.v Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Palisades Plant ATTN:

Mr. Joseph F. Firlit General Manager 27780 Blue Star Memorial Hwy.

Covert, Michigan 49043

Regional Radiation Representative 230 South Dearborn Street Chicago, Illinois 60604 Resident Inspector c/o U.S. NP.C Palisades Plant 27782 Blue Star Memorial Hwy.

Covert, Michigan 49043