\\J consumers Power company General Offices: 1945 West Parnall Raad, Jackson, Ml 49201
- 15171 788-0550 November 30, 1984 Joyce Tichler Atmospheric Scietices Division Brookhaven National Laboratory Upton, NY 11973 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -
JE FILE copy, C-:..0 CONSUMERS POWER COMPANY COMMENTS ON BROOKHAVEN NATIONAL LABORATORY DRAFT REPORT, EFFLUENT AND WASTE DISPOSAL.ANNUAL REPORT FOR YEAR 1983 The summary of radioactive effluents released from the Palisades Plant during 1983 sent to us October 31, 1984 has been reviewed by Consumers Power Company and found to be acceptable with the following corrections:
- 1)
Page 1 - Liquid Effluents Nuclides Released H-3 2.35E + 02 Ci
- 2)
Page 8
- C Particuletes Average Release Rate for Period - Quarter 4 1.32E-04 UCI/SEC For clarity marked copies of the revised pages are attached.
Brian D Johnson (Signed)
Brian D Johnson Staff Licensing Engineer CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades Attachments 1---9-4-1-2 =3-.:o:-=3:::9:::e::--<:;::;*e:';'i~I7 1:;;3"o-
.. -_,_,;\\
PDR ADOCK *0.5,0.0()~5~
R OC1184-0011-NL02
\\ -
,J OC1184-00ll~NL02 ATTACHMENT Consumers Power Company - Palisades Plant Docket 50-255 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT FOR THE YEAR 1983 2 Pages
INSTALtATION1PALISADES LOCATION15 HI S SOUTH HAVEN, MI EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT FOR VEAR 1983 AIRBORNE AND LIQUID EFFLUENTS UNIT NUMBER* l TVP E 1 P\\JR DOCKET N0.158-255 LICENSEE1CONSUMERS PO\\JER LICENSED PO\\JER CM\\JT)125J8.BB INITIAL CRITICALITV185/24/71 COOLING \\/ATER SOURCE1LAKE MICHIGAN AIRBORNE EFFLUENTS NUCLIDES RELEASED BE-7 AR-4 l MN-54 C0-58 C0-68 SE-75 KR-85 KR-85H KR-87 KR-88 1-131
><E-131M 1-132 1-133
><E-133
><E-133M CS-134 1-135
><E-135
><E-135H CS-137 UNIDENTIFIED LIQUID EFFLUENTS NUCLIDES RELEASED H-3 CR-51 MN-54 co-50 C0-68 NB-95 ZR-95 AG-118H 1-l 3 l I-133
><E-133 CS-134 CS-136 CS-137 BA-14" LA-I 40 UNIDENTIFIED N/A*NOT APPLICABLE N/D*NOT DETECTED N/R 0 NOT REPORTED ACTIVl*TY !CI>
2.45E-86 2.69E-82 3.89E-86
- 6. 64E:..05 7.75E-85 l.83E-83 3.12E+88 9.96E-02 6.33E-82 l.47E-81 3.31E"-82 I. 78E+08" 2.57E-83 l.46E-02 2.99E+83 9.BlE-82 4.19E-86 6.48E-83 6.71E-81 4.91E-81 5.B2E-85 4.26E-85 ACTIVITY ICI)
~
9 65..,..... :l *.3J ~ +IJ-\\.
l.52E-05 3.17E-83 3.66E*82 l.15E-82 7.88E-86 2.26E-B6 Z.98E-85 3.UE-84 5.52E-87 2.53E-82 7.29E-83 2.llE-85 I. 46E-9'2 l.58E-84 9.36E-85 8.77E-84
INSTALLATION=PALl~ADES EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT FOR 1983
-~
GASEOUS EFFLUENTS -
SUMMATION OF ALL RELEASES UNIT QUARTER QUARTER EST TOTAL 3
4 ERROR X A.FISSION AND ACTIVATION GASES
- 1. TOTAL RELEASE Cl
- 2. AVERAGE RElEASE RATE FOR PERIOD UC I/SEC I.9'2E 2
- 1. 66E-3
- 3. PERCENT OF TECHNICAL SPECIFICATION L IHIT x
6.82E-2 l.llE-6
- e. IODINES I. TOTAL IODINE-131 Cl
- 1. 89E-2
- 8. I SE-4 5.ZBE B
- 2. AVERAGE RELEASE RATE FOR PERIOD UC I/SEC 2.26E-3 l.BJE-4
- 3. PERCENT OF TECHNICAL SPECIFICATION LIMIT x
l.58E-I
- 7. 29'E-3
- c. PARTICULATES
). PARTICULATES \\/ITH HALF-LIVES >B DAYS Cl I.SSE-4 I.SSE-3 2.92E 14
- 2. AVERAGE RELEASE RATE FOR PERIOD UC I/SEC 1.BBE-5 ~e-+ 1.az£".-"
- 3. PERCENT OF TECHNICAL SPECIFICATION LIMIT x
I. 34E-..
l.97E-4
- 4. GROSS ALPHA RADIOACTIVITY Cl 1.6BE-6 l.19E-6 D. TRITIUM
). TOTAL RELEASE Cl I. 78E B
2.38E B
- 2. AVERAGE RELEASE RATE FOR PERIOD UC I/SEC Z.24E-1 2.99E-I
- 3. PERCENT OF TECHNICAL SPECIFICATION L IHIT x
2.24E-4 2.99E-..
N/DaNOT DETECTABLE N/AaNOT APPLICABLE