Docket No.:

50-255 LS05-84 011 Mr. David J. VandeWalle Nuclear Licensing Administrator Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201

Dear Mr. VandeWalle:

August 8, 1984

SUBJECT:

ENVIRONMENTAL REVIEW FOR LICENSE CONVERSION Re:

Palisades Plant t

In preparation for the conversion of the provisional dperating license for the Palisades PTant, the NRC staff is assessing what updating of the informa-tion in the Final Environmental Statement (FES) and Final Addendum to the FES will be necessary.

We find that additional information is needed to continue

. our review.

Please pro~ide your response to the enclosure within 30 days of the receipt of this letter. The items in the enclosure have been discussed with your staff.

The reporting and/or recordkeeping requirements contained in this. letter.

affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

Enclosure:

As stated cc w/enclosure:

See next' page DISTRIBUTION NRC PDR L PDR OELD ACRS (10)

Docket 50-255 ORB#5 Rdg.

WPaulson CJamerson JLyons JNGrace ELJordan Sincerely, Original signed by Walter A.

Paulson~ Acting Chief

  • Operating Reactors Branch #5 Division of Licensing EHE-t(JU o~
  • ,~

ORB#5:LA~

CJamerson k 7 /'J-t,/84 ORB~PM JLy~

7 I ;_fl/84 R.B!~*

(;,! f /84 WP~lson

'I /'J /84 SEOI J

Mr. David J. VandeWalle cc M. I. Miller, Esquire Isham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois 60670 Mr. Paul A. Perry, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 James G. Keppler, Regional Administrator Nuclear Regulatory Comrni.ss ior:i,_ -~~gion I I I 799 Roosevelt Road Glen Ellyn, Illinois 60137 Township Supervisor Covert Township Route 1, Box 10 Van Buren County, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Palisades Plant ATTN:

Mr. Robert Montross Plant Manager Covert, Michigan 49043 U.S. Environmental Protection Agency Federal Activities Branch Region V Office ATTN:

Regional Radiation Representative 230 South Dearborn Street Chicago, Illinois 60604 Resident Inspector c/o U.S. NRC Pa 1 i sades Pl ant Route 2, P. 0. Box 155 Covert, Michigan 49043 August 8, 1984 *------

Lee E. Jager, P.E., Chief Environmental and Occupational Health Services Administration Michigan Department of Public Health 3500 N. Logan Street Post Office Box 30035 Lansing, Michigan 48909

/

291.1 291.2 291.3 291.4 REQUEST FOR ADDITIONAL INFORMATION PALISADES PLANT The NPDES Pennit Monitoring Requirement A.9 required the licensee to conduct a study of the free-chlorine component of the total residual chlorine.

Provide a copy of this report and, when available, a copy of the State's review of this report.

The NPDES Pennit Monitoring Requirement A.10 required the licensee to conduct a chlorine minimization study to determine the minimum quantity of chlorine necessary to prevent biofouling of the cooling system.

Provide a copy of this report and, whe.n available, a copy of the State's review of this report.

Specify the changes in intake volume from the lake as a result of elimination of dilution pumping.

In the 1978 final addendum to the Palisades FES Section 10.1.5.4 the staff recommended that the applicant inspect for leakage in the water distribution channels and all other sources of additional drift and larger drops (of water) and report to*the staff all repairs undertaken to correct leaks in the water distribution system and all other sources of additional dri.ft. Please provide the results of------ - --

these inspections and repairs.