Docket No.50-255 MEMORANDUM FOR:

FROM:

SUBJECT:

Date & Time:

Location:

Purpose:

Participants:

March 28, 1984 e Dennis M. Crutchfield, Chief Operating Reactors Branch #5, DL Walter A. Paulson, Project Manager Operating Reactors Branch #5, DL FORTHCOMING MEETING WITH CONSUMERS POWER COMPANY -

PALISADES PLANT Tuesday, April 10, 1984 9:00 am Room P-114, Phillips Building Bethesda, Maryland To discuss Palisades steam generator repair (see enclosed agenda).

Consumers Power Company D. VandeWa 11 e W. Beckius J. Jandovitz J. Hinkle J. Schepers NRC W-:-Paulson C. Cheng H. Conrad C. McCracken J. Rajan L. Lois B. Mann W. Key (Region III)

Original signed by Walter A. Paulson, Project Manager Operating Reactors Branch #5 Division of Licensing cc: See next page DL~ #5 V./Paulson:jc 3 /'Y~/84 g~~~~~~~,

.:J /:J~/~~

~g~33000b4 840328 ---- --------

p ADOCK 05000255 PDR

Mr. David J. VandeWalle cc M. I. M i 1 1 er, Es q u i re Isham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois 60670 Mr. Paul A. Perry, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 James G. Keppler, Regional Administrator Nuclear Regulatory Commission, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Township Supervisor Covert Township Route 1, Box 10 Van Buren County, Michigan 49043 Office of th~ Governor Room 1 - Capitol Building Lansing, Michigan 48913 Palisades Plant

  • ATTN:

Mr. Robert Montross Plant Manager Covert, Michigan 49043 U.S. Environmental Protection Agency Federal Activities Branch Reqion V Office ATTN:

Regional Radiation Representative 230 South Dearborn Street Chicago, Illinois 60604 Resident Inspector c/o U.S. NRC Palisades Plant

~oute 2, P. 0. Box 155 Covert, Michigan 49043 Lee E. Jager, P.E., Chief Environmental and Occupational Health Services Administration Michigan Department of Public Health 3500 N. Logan Street Post Office Box 30035 Lansing, Michigan 48909

Meeting Between Consumers Power Company and NRC Palisades Steam Generator Repair April 10, 1984 AGENDA Introduction & Purpose Failure Analysis - Metallurgical Test Program, Damage Scenario ET Examination - Qualification Program, Location and Size of Defects, Rate of Defect Growth Steam Generator Tube Repair Criteria Condition of Support Plates Required Licensing Actions & Schedule

4 DISTRIBUTION

. ---DOcket--Fi--1 e-*_

NRC PDR Local PDR NSIC ORB #5 Reading FMiraglia GHolahan HDenton DCrutchfield LA PM OELD ELJordan JMTayl or ACRS {10)

SEPB MSchaaf NRC Participants Receptionist Phillips Building cc list

Docket No.50-255 e

UNITED STATES e

NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 March 28, 1984 MEMORANDUM FOR:

Dennis M. Crutchfield, Chief Operating Reactors Branch #5, DL FROM:

Walter A. Paulson, Project Manager Operating Reactors Branch #5, DL

SUBJECT:

FORTHCOMING MEETING WITH CONSUMERS POWER COMPANY PALISADES PLANT Date & Time:

Tuesday, April 10, 1984 9:00 am Location:

Room P-114, Phillips Building Bethesda, Maryland

Purpose:

Participants:

To discuss Palisades steam generator repair (see enclosed agenda).

Consumers Power Company D. VandevJalle W. Beckius J. Jandovitz J. Hinkle J. Schepers NRC W:-Paulson

  • c. Cheng H. Conrad
  • c. McCracken J. Rajan L. Lois B. Mann

\\.!.Key (Region III)

!Jo.PAA*~

Walter A. Paulson, Project Manager Operatin~ Reactors Branch #5 Division of Licensing cc: See next page

-: ~-- -

~