June 30, 1982 DISTRIBUTION Docket Docket No. 50-255 LS05..;;82-06-l29 NRC PDR Local PDR ORB Reading NSIC DCrutchfield HSmith TWambach OELD Mr. David Vandewalle Nuclear Licensing Administrator Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201

Dear Mr. VandeWalle:

OI&E ACRS (10)

SEPB

SUBJECT:

TMI ACTION PLAN ITEM II.K.3.3, REPORTING RELIEF VALVE AND SAFETY VALVE FAILURES /\\ND CHALLENGES - PALIS.l\\DES PU\\NT We have reviewed your response dated December 19, 1980 to the above TMI Action Plan item.

Your response states that all challenges and failures of the safety valves and relief valves must be reported in accordance w*ith the Technical Specifications for the Palisades Plant.

No further revie\\v of this item by NRR is planned.

Because you have stated that you meet the above reporting requirements~ we consider this item resolved for your facilit.Y.

cc:

See next page

--~gcr7o9013-3-926630

  • __ -_~~ _ -, "'

p R ADDCK 05000255 PDR OFFICE'* D.L:... _,QRS..J§,.. D6¥>J7iJ#t,7..

ti -v ~,, DciMl!lf're1 d SURNAME> T-W.am~~wn+eE::**........................

DATE. f?..f.~!'./.82........ ~.1.91J1.a2........

Sincerely, Original signed by Dennis M. Crutchfield, Chief Operating Reactors Branch C5 Division of Licensing NRG FORM 318 (10-80) NRCM 0240 OFFICIAL. RECORD COPY USGPO: 1981-335-960

Mr. David June 30, 1982 cc M. I. Miller, Esquire Is"ham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois 60670 Mr. Paul A. Perry, Secretary Consumers Power Company

  • 212 West Michigan Avenue Jackson, _Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michjgan Avenue Jackson, Michigan. 49201 CHERRY & FLYNN Suite 3700 Three First National Plaza Chicago, Illinoi~ 60602 Ms. Mary P. Sinclair Great Lakes Energy Alliance 5711 Summerset Drive Midland, Michigan 48640.

William J. Scanlon, Esquire 2034 Pauline Boulevard

____ A_i:!n_ Arbor, Michigan 48103 Township Supervisor Covert Towns!'ti Route 1, Box 10 Van Buren County, Michigan 49043 Office of the Governor (2)

Room l - C_apitol Building

  • - ~~an_si~~-~ Michigan 48913 Palisades Plant ATTN:

Mr. Robert Montross

Regional Radiation Representative

  • 230 South Dearborn Street Chicago, Illinois 60604
  • Mr. James A. Laurenson, Chairman Atomic Safety and Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Dr; George C. Anderson D~parpnent of Oceanography University of Washington Seattle, Washington 98195 Dr. M. Stanley Livingston 1005 Cal1e Largo Santa Fe, New Mexico 87501 R£siden~Inspector c/o U.

S._l:H~C Pal isade°f1>1ant Route 2, P. 0. Box 155 Covert, Michigan 4904~.

James'G. Keppler, Regional Administrator Nuclear Regulatory Commission, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137