Application to Amend License DPR-20,improving Containment Isolation Dependability & Meeting Intent of TMI Action Item II.E.4.2
ML18046B339
Person / Time
Site: Palisades 
Issue date: 03/01/1982
From: Vandewalle D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
Shared Package
ML18046B340 List:
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.E.4.2, TASK-TM NUDOCS 8203080334
Download: ML18046B339 (2)


Text

\\ '--

consumers

  • Power company General Offices: 1945 West Parnell Road, Jackson, Ml 49201 * (517) 788-0550 March 1, 1982 Dennis M Crutchfield, Chief Operation Reactor Branch No 5 Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR David J VandeWalle Nuclear Licensing Administrator RECEIVED MAR 051982*

PALISADES PLANT - PROPOSED TECHNICAL SPECIFICATIONS CHANGE REQUEST -

CONTAINMENT ISOLATION PRESSURE SET POINT Attached are three (3) originals and thirty seven (37) conformed copies of a request for change to the Palisades Technical Specifications.

The requested change improves containment isolation dependability and meets the intent of NUREG-0737, Item II.E.4.2.

The bases for arriving at the appropriate minimum pressure set point for initiating containment isolation included containment pressure history and instrument performance.

The containment isolation pressure set point established is the result for an agreement reached between the NRC and Consumers Power Company.

The proposed change involves a single safety issue.

Therefore, a check in the amount of $4,000.00 is attached pursuant to 10 CFR 170.22, Class III change.

Nuclear Licensing Administrator CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades ATTACHMENTS

Request Ir CONSUMERS POWER COMPANY Docket 50-255 Change to the Technical License DPR-20 e

SpecificatiOns For the reasons hereinafter set forth, it is requested that the Technical Specifications contained in the Provisional Operating License DPR-20, Docket 50..,,255, issued, tg Consumers Power Company on October 16, 1972*, f'or the Palisades Plant be changed as described in Section I below:

I.* Changes A.

Change Section 2. 3, Table 2. 3.1* (7) to read:

" 7, Containment High

  • Pressure

< 3. 70 Psig B.

Change Section 3.16 to read:

"Basis

S 3. 70 Psig

~ 3. 70 Psig "

r+o.4o)*

a.

High Containment Pressure ~_The basis for the 4 psig \\~0.30 set point for the high-pressure signal is to establish a setting which would be reached immediately in the event of a DBA, cover a spectrum of brea~ sizes and yet be far enough above normal operation maximtnn internal pressure.to prevent spurious initiation. (1,.2) 11 C.

Change Secti.on 3.16, Table 3.16.1 (1) to read:

"l.. High Containment Pressure

a. *safety Injection

. 3. 70

b.

Containment Spray

c.

Containment Isolation

d.

Containme~t Air Cooler DBA Mode 4.40 Psig"

. NOTE:

Revised Technical Specifications pages are attached.

Proposed changes are shown by a vertical, 'line in the rig~t-hand margin.

II. Discussion The Technical.Specifications change provides for improved containment isolation

. dependability.

The pressure set point is based upon the maximtnn observed pressure inside containment during normal operation:of,99 Psig and allowances f()r instrtnnent drift.an_d* fluctuation due to the ac;curacy of the pressure sensor.

In addition, the revi.sed pressure.set point was deemed appropriate when reviewed against ISA draft 867. 04.

This change was requested by the.'NRC and meets the int~nt of NUREG-0737, Item II.E.4.2, position 5.

III. Conclusion Based on the foregoing, l:>oth the Palisades. Pl'artt.Review Comn:d.ttee and the Safety and Audit Review Board have reviewed these changes.and find them acceptable.