ML18045A798

From kanterella
Jump to navigation Jump to search
Immediate Action Ltr Withdrawing 83% Power Level Restriction from Facility.Personnel Must Be Instructed & Procedures Updated to Require Initial Auxiliary Feedwater Flow of 300 Gpm to Single Steam Generator
ML18045A798
Person / Time
Site: Palisades 
Issue date: 10/01/1980
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Youngdahl R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
NUDOCS 8010170034
Download: ML18045A798 (1)


Text

,,.........,

\\* -

~

NUCLEAR REGULATORY COMMISSION REGION Ill 799 ROOSEVELT ROAD GLEN ELLYN, ILLINOIS 60137 Docket No. 50-255 Consumers Power Company ATTN:

Mr. R. C. Youngdahl Executive Vice President 212 West Michigan Avenue Jackson, MI 49201 Gentlemen:

October 1, 1980 This refers' to the Immediate Action Letter of September 4, 1980, regarding the limitation of Palisades Plant power.level to 83% pending further evaluation of auxiliary feedwater flow rates. and feedwater system water hammer.

As a result of ineetings held.in Bethesda, Maryland on September 30, 1980, between representatives of the Consumers Power Company*and NRC staff members, this power level restriction is withdrawn with.the understanding that the following items will be performed:

1.

Plant operations personnel are immediately instructed, and appropriate plant operating and emergency procedures are updated in a timely manner, to require an initial auxiliary feedwater flow rate of 300 gpm to a single steam generator in the event that the full power cooldoivn load is imposed on a single steam generator.

2.

Studies will l;>e*initiated such that by December 1, 1980, a program and schedule will be defin~d for the. mitigation or eliniination of feedwater line and steam generator water hammer~

Please inform us immediately if your understanding of these items is different from that stated above.

cc:

Mr. D. P. Hoffman, Nuclear Licensing Administrator Mr. R. W. Montross, Manager Central Files AEOD R~production 1vPDR

' LPDR NSIC TIC Unit NRC 20B Ronald Callen, MPSC Myron M. Cherry, Chicago 1

Sincerely,

~

t..>/~"';f

~James G. Keppler

()-Director

~IMMEOt-AT&:

__.;,ACTi ON.. L~TTEH*

/