ML18045A420

From kanterella
Jump to navigation Jump to search
Forwards LER 80-020/01T-0
Date released: 10/31/2018 Download: ML18045A420


LER 80-020/01T-0:on 800711,control Rod Drive Mechanism Failed to Operate Properly,Resulting in Rod Being Misaligned for Approx Five Minutes.Caused by Dirty Control Relay Armatures & Contractor Interlock Which Resulted in Sticking
ML18045A421
Person / Time
Site: Palisades Entergy icon.png
Issue date: 07/29/1980
From:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML18045A421 (1)
Forwards LER 80-020/01T-0
ML18045A417
Person / Time
Site: Palisades Entergy icon.png
Issue date: 07/29/1980
From: Hoffman D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML18045A417 (2)