OCT 2 1979 Docket No. 50-255
- )
- LICENSEE:
Consumers Power Company (tPCO)
FACILIT,Y:
Palisades Plant
-s~BJECT:
SUMMARY
OF SEPTEMBER.26, 1979 MEETING WITH CONSUMERS POWER COMPANY ON PROPOSED *:HEAtUF:i: 'ANrr.£00LDOkJN '.'CURVES On September 26, 1979, we met with repr~~entatives pf.CPCO to discuss proposed revisions on pressure temper9t4re limits. A list of attendees
- . 1s attached.
'\\
/
The.subject of the meeting was the CP,CO a*1J1endment request dated *July 2, 1979 and an NRC response dated August*21, 1979.
The August 21, 1979
- letter found the July 2, 1979 r~quest unacceptable for three reasons:
~. one related to uncertainties in end-of-life vessel fluence, the* second
- related to. the un1rra~fa_te~ v~lue of RTNDT, and the third related tq the increase 1n RTNDT with r~d.ia~Jon-dam~ge *., It was agreed that disoussion.
of end-of-life fluence woula be deferred for about one week pending..
additional.calculations to be perfor111e~ ~Y the CPCO consultant. **The NRC staff provided additional backgrQµnd for the *positions stated in
- items (2) and (3) 1n the August' 21, 1979 letter. The CPCO represen-tatives provide~ additional data* wit~ r~spect to vessel welds (attached).
Based on the-meeting an understand1ng wa~ reached that CPCO would submit revised pressure. temperature operating 11mits based on th.e August 21,
- 1979 NRC 1 etter subsequent to ver1 fy1 rm ihe end-of-1 i fe fl uence.
- Original Signed by*
~!chard D. Sil v.era
- Rich~rd D~ Silver, Project Manager Operating Reactors Branch #2 D1yis1on of Operating Reactors.
. Attachments:
- 1. List of Attendees
-2._. Data Sheet
- ~
cc:
See next page
- . /?91o3/0003
. OPPIC:BJ>
01.IRNAIH~.
RD lver:sah DLZiemann DATK~
... loi'£i1*9*.. ** *-*... ~i~79........ _
............... ~..................................................................................
Nae.PORM 318 (9-76) NB.CM 0240
- u.a. OOVlrRNMllNT PRINTING OP"P"ICB: t 871 - Zll - 1**
i
)_/
\\J.
MEETING
SUMMARY
DISTRIBUTION:
'icket so-2s[)
.C PDR..
\\,.
- . Lo*C:J,>l/i:~DR '/\\',
.0Rtr#2 *Readin~r..
"_:.,d1',,NRR Readin.g -
H. R. Denton. ;
E. G. Case
- o. Eisen hut R. Vollmer
- B. Grimes w.* Gammill J. Miller L Shao.
T. Carter D.
- Crutchff eld
, D. Zf emarm
- v. Noonan Se1 smi c Review Group*
. A. Schwencer T. Ippolito
- R. Reid.
G. Lainas.
P. Check R. Clark F.-Pagano G. Knighton*
R. Silver
- OELD Ol&E(3)
H. Smith R.
Fraley~ ACRS(-16)
- K. Hoge C.Cheng H. *Randal 1 J. R. Buchanan.
. TERA
' \\
(*
+
_' --~
\\,.
l.' "
REGU1 n~n..
uilURV DOCKET FILE COPY.
I Y\\/\\(~
/
i i
l 1
t' t
'CIP'P'ICB.
,.......... *..... : *.'.... *.................... ~
w-***~ [................. ~--**.................... -**********............ -............................................. ~..................
DATii:~
N&C PORM 318 (9*76) NRCM 0240
- u.11. CIOVll~NMllNT PRINTING oprir1c11: t 971
- 111
- 1 **
. l
...,,. ~o~n~umers Pow.er Company
/~
cc M. I. Mil1er, Esquire Isham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois 60670 Mr. Paul A. Perry, Sesretary Consumers Power Company 212 West Michigan Avenue
- Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Myron M. Cherry, Esquire Suite 4501 One IBM Plaza Chicago, Illinois 60611 Ms. Mary P. Sinclair Great Lakes Energy Alliance 5711 Summerset Drive Midland, Michigan 48640 Charles Bechhoefer, Esq., Chairman Atomic Safety and Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Or. George C. Anderson Department of Oceanography University of Washington Seattle, Washington 98195 Or. M. Stanley Livingston 1005 Calle Largo Santa Fe, New Mexico 87501 Kalamazoo Public Library 315 South Rose Street Kalamazoo, Michigan 49006 OCT 2 1979 Mr. David Bixel Nuclear Licensing Administrator Consumers Power Company 212 West Michigan Avenue Jackson,. Michigan '49201
CPCO
- S. Ca she 1'1
- _
- R. Jenkins NRC R. Silver K. Hoge C: Cheng *
.H. Randal 1 Att<,lchment 1 LIST OF ATTENDEES
.. SEPTEMBER 26, 1979 I.
........ t.
t *. l t
t I
w-****........................ ~............................. :.................. ~................................................ ~...... **........
0 DATIE.
l<&C FORM 318 (9-76) NRCM 0240
- ~.&. OOVBRNM*NT PRINTING OP'P'ICB: 1171... 181 - 711
- 2)
CP~o has reviewed the referenced Standard Review Plan for its appropriateness with respect to setting unirradiated reference temperatures.
Additional WELD A
B c
D E
F G
H data on Combustion Engineering welds was sought in order to provide a reasonable technical basis for determining a FTNDT for Palisades vessel weld metal.
Table 1 contains data on eight CE weld.men-ts nominally the same with respect to wire and *flux as those employed in the fabrication of:
TABLE 1 Combustion Engineering Charpy Weld 0
Data -
-80
-65
-60
-70
-70
-60
-45
-45
-50
-50
-55
-35
-35
-60
-60
-45
-30
-39
-60
-60
-80
-70
-80
-70
-70
-60
-50
-50
-70
-70
-50
-10
-10
-70
-70
-60
-20
-20
-70
-70 TABLE 2 Charpy Base Metal Data from Palisades Surveillance Program - OF Material T30 T50 T035 NDTT RTNDT Base Long 0
20 5
-10
-10 Base Trans 25 55 40 O*
TABLE 3 Charpy Weld Metal Data From Palisades Surveillance Program -
-85
-50
- Reference Temperature Determined Per Section NB-2331 (a,3) of the ASME Boiler and Pressure Vessel Code,Section III, Division I, 1977 ed.
. t.
MEETING
SUMMARY
DISTRIBUTION:
Docket 50-255 N
ocal PDR 0
eading NRR Reading H. R. Denton E. G. Case D. EisenhLit R. Vollmer B. Grimes W. Gammi 11.
J. Miller L. Shao T. Carter D. Crutchfield D. Ziemann V. Noonan Seismic Review Group A. Schwencer T.. Ippolito R. Reid G. Lainas P. Check R. Clark F. Pagano G. Knighton R. Silver OELD OI&E (3)
H. Smith R. Fraley, ACRS(l6)
K. Hoge C. Cheng H. Randall**
J.. R. Buchanan TERA
UNITED STATES....
NUCl.EAR REGULATORY.COMMISslON :
WASHINGTON, D. C. 20555...
October 2, 1979 Docket No. 50-255 LICENSEE:
Consumers Power Company (CPCO)
FACILITY:
Palisades Plant
SUBJECT:
SUMMARY
OF SEPTEMBER.26_, 1979.MEETING WITH.CONSUMERS POWER COMPANY ON PROPOSED HEATUP AND COOLDOWN CURVES On September 26, 1979, we met with represeritatives of CPCO to discuss*
proposed revisions on pressure temperature limits. A list of attendees is attached.
The subject of the meeting was the CPCO amendment request dated July 2, 1979 and an NRC response dated August 21, 1979.
The August 21, 1979 letter found the July 2, 1979 request unacceptable for three reasons:
one related to uncertainties in end-of-life vessel fluence, the second related to the unirradiated value of RTNDT' and the third related to the increase in RTNtiT with radiation damage.
It was agreed that discussion of end-of-life fluence would be deferred for about one week pending additional calculations to be performed by the CPCO consultant. The NRC staff provided additional background for the positions stated in items (2) and (3) in the August 21, 1979 letter. *The CPCO represen-tatives provided additional data with respect to vess~l welds (attached).
Based on the meeting an understanding was reached that CPCO would submit revised pressure temperature operating limits based on the August 21, 1979 NRC letter subsequent to verifying the end-of-life fluence.
- Attachments:
- 1.
List of Attendees
- 2.
Data Sheet
\\
\\---
f f*-
I l.
\\
\\,,. ""'.... ~.....
'*4.
~.:-:.-.....
~~ l -., '-* '---
Richard D. Silver, Project Manager Operating Reactors Branch #2 Division of Operating Reactors cc:
---See-next-page _______ ---
Coniumers Power Company cc M. I. Miller, Esquire Isham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois 60670 Mr. Paul A.
Perry,.Se~retary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Myron M. Cherry, Es qui re*
Suite 4501,
One IBM Plaza Chicago, Illinois 60611 Ms. Mary P. Sinclair Great Lakes Energy Alliance 5711 Summerset 'Drive Midland, Michigan 48640 Charles Bechhoefer, Esq., Chairman Atomic Safety and Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D. c.
20555 Dr. George C. Anderson Department of Oceanography University of Washington Seattle, Washington 98195 Dr. M. Stanley Livingston 1005 Cal 1 e Largo Santa Fe, New Mexico 87501 Kalamazoo Public Library 315 South Rose Street Kalamazoo, Michigan 49006 October 2., l 9Z9 Mr. David Bixel
~-------
--Nucl ear-tfcerfsinq-AamTriTstrafor ___ _
Consumers Power Company 212* West Michiqan Av.enue Jackson, Michigan 49201
CPCO S. Cashell R. Jenkins NRC R. Silver K. Hoge C. Cheng*
H. Randall LIST OF ATTENDEES
.. SEPTEMBER.2f)', l,9.J9 *.
- At.tachment.,
l*
e Attachnient.2
- 2) 8PCo has reviewed the referenced Standard Review Plan for its appropriateness*
with respect to setting unirradiated reference temperatures.
Additional data on Combustion Engineering welds was sought in order to provide a reasonable technical basis for.determining a:,FT NDT. for Palisades vessel weld metal;. Table 1 contains *data:* on eight.CE* weldnent;s nominally the same with
.. respe~t to wire and flux as t:qose ~mployed in* the fabrication of:
TABLE 1 Combustion Engineering Charpy Weld 0
Data -
F WELD T30 T50 T035 NDTT RTNDT A
-80
-65
-60
-70
-70 B
-60
-45
-45
-50
-50 c
-55
-35
-35
-60
-60 D
-45
-30
-39
-60
-60 E
-80
-70
-80
-70
-70 F
-60
-50
-50
-70
-70 G
-50
-10
-10
-70
-70 H
-60
-20
-20
-70
-70 TABLE 2 Charpy Base Metal Data from Palisades Surveillance Program - OF Material T30.
Base Long 0
20 5,
-10
-10 Base Trans 25 55 40 '
O*
TABLE 3 Charpy Weld Metal Data From Palisades Surveillance Program -
9F Material T30 T50 T035.
--~* !-*-----* - ________ ! __________ _
-85. __
.::5_0 _________ 55 __ : __ _:. *
-- ---~-------- -----------
- Reference Temperature Determined Per Section NB-2331 (a,3) of the ASME Boiler and Pressure Vessel Code,Section III, Division r,*1977*ed.
~.' ;
j
. MEETING SUMMAR{ DISTRIBUTION:
Docket 50-255 NRC PDR
. Local PDR ORB#2 Reading NRR Reading
.H. R. Denton
- E. G. Case D. Eisen hut R. Vollmer B~ Grimes W. Gammi 11 J. Miller L. Shao T. Carter D. Crutchfield D: Ziemann V. Noonan Seismic Review Group A. Schwencer T. Ippolito R. Reid G. Lainas P. Check R. Clark F. Pagano G. Knighton R. Silver OELD OI&E {3)
H. Smith R. Fraley, ACRS(l6)
K. Hoge C. Cheng H. Randall
- J.
- t Buchanan*
Crrn~~
I
)
I Docket No. 50-255 l.JNITED STATES..
NUCt.EAR REGULATORY'.CQMMISSION.
- WASHINGTON, D. C. 20555 October 2, 1979 LICENSEE:
Consumers Power Company (CPCO)
FACILITY:
Palisades Plant
SUBJECT:
SUMMARY
OF SEPTEMBER 26.,' 1979 MEETING WITH. CONSUMERS POWER COMPANY ON PROPOSED HEATUP AND COOLDOWN CURVES On September 26, 1979, we met with representatives of CPCO to discuss proposed revisions on pressure temperature limits'. A list of attendees is attached.
The subject of the meeting was the CPCO amendment request dated July 2, 1979 and an NRC response dated August 21, 1979.
The August 21, 1979 letter found the July 2, 1979 request unacceptable for three reasons:
one related to uncertainties in end-of-life vessel fluence, the second related to the unirradiated value of RTNDT' and the third related to the increase in RTNOT with radiation damage.
It was agreed that discussion of end-of-life fluence would be deferred for about one week pending additional calculations to be performed by the CPCO consultant.
The NRC staff provided additional background for the positions stated in items (2) and (3) in the August 21, 1979 letter. *The CPCO represen-tatives provided additional data with respect to vessel welds (attached).
Based on the meeting an understanding was reached that CPCO would submit revised pressure temperature operating l.imits.based on the August 21, 1979 NRC letter subsequent to verifying the end-of-life fluence.
Attachments:
- l. List of Attendees
- 2.
Data Sheet cc:
------See--nex t*-*page _______ _
Richard D. Silver, Project Manager Operating Reactors Branch #2.
Division of Operating Reactors
e Consumers Power.company.
cc M. I. Miller, Esquire Isham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois 60670 Mr. Paul A. Perry, Se~retary Consumers Power Compariy 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue J ackscn, Michigan 49201 Myron M. Cherry, Es qui re Suite 4501 One IBM Plaza Chicago, Illinois 60611 Ms. Mary P. Sinclair Great Lakes Energy Alliance 5711 Summerset Dri~e Midland, Michigan 48640 Charles Bechhoefer, Esq., Chairman Atomic Safety and Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D. c.
20555 Dr. George C. Anderson Department of Oceanography University of Washington Seattle, Washington 98195 Dr. M. Stanley Livingston 1005 Calle Largo Santa Fe, New Mexico 87501 Kalamazoo Public Library 315 South Rose Street Kalamazoo, Michigan 49006 Mr. David Bixel
--*-----Nacrear-TTcerisTnq *-A-ami nTsTra-for ____ ---
Consumers Power Company 212 West Michiqan Av.enue Jackson, Michiqan 49201 October 2., 1979
CPCO S. Cashell R. Jenkins NRC R. Silver K. Hoge C. Cheng H. Randall LIST OF ATIENDEES.
SEPTEMBER 2fr. 197,9,
~ Attachment 2
- 2) ~ CPCo has reviewed the referenced Standard Review Plan for its appropriateness*
with respect to setting unirradiate-d reference temperatures.
Additional data on Combustion Engineering welds was sought in order to provide a reasonable technical basis for determining a.FTND'J' for Palisades vessel weld metal 1 Table 1 contains*data: on eight.CE weld.men-rs nominally the same with
.respect to wire and flux.as* those *employed in.the fabrication of:
- TABLE 1 Combustion Engineering Charpy Weld 0
Data -
F WELD T30 T50 T035 NDTT RTNDT A
-80
-65
-60
-70
-70 B
-60
-45
-45
-50
-50 c
-55
-35
-35
-60
-60 D
-45
-30
-39
-60
-60 E
-80
-70
-80
-70
-70 F
-60
-50
-50
-70
-70 G
-50
-10
-10
-70
-70 H
-60
-20
-20
-70
-70 TABLE 2 Ch~py Base Metal Data from Palisades.Surveillance Program - OF.
Material T30 T50 T035 NDTT RTNDT Base Long 0
20
- 5.
...:10
-10 Base Trans 25 55 40 O*
TABLE 3 Charpy Weld Metal Data From Palisades Surveillance Program -
9F Material NDTT
_________ _\\ielQ_ ________ =-8.5 ______.=5.o _ _:_ _______ g§c-----------:--~!---------?---------:..-
-*Reference Temperature Determined Per Section NB-2331 (a,3) of the ASME Boiler and Pressure Vessel Code,Section III, Division I, 1977 ed.