JUL 12 1979

),_

Docket No. 50~255 Ii*

Mr.** David Bi xe*l

. :. '1

  • ~,~

Nt.icl ear L iee*ns_ing* A<imi n*1 strator' Consumers Powe*r CQmpany 212 West MiGhigan,l\\venue, Jackson-, Michigan : 49201 _

~

Dear. Mr. Bixel:

-- __J

/\\ * </ _.'

.... I

_,./(. --f buri ng -the managemeri.t i,pspe~tion at Pali sa~,~s* during the \\iieek of

'"/~>'

- -November 27, 1978, our Pffi ~e of lnspectio~j atid Enfgrcement found

/.

  • --- that you are using ballot.type reviews for !:both the Plant Review*.

/

Co_rrmittee (P-RC) and-the Safety and Audit Re:v1ew Board (SARB).. - As'

l.

you were 1nforme~ during the inspection and by Inspection* Report 50-255/78-30 the ballot type review* does not conform with the position of NRR and Ol&E that each cotrnnittee must formally-convene a quorum to act on issues for which it is responsi.ble *. Our, position

  • on conmi ttee performance is stated fo the sections addressing re~{ew

-committee quorum requirements in the Standard Technical Specifications issued with *new operating licenses. Suggested 'Technical Specification -

changes for Palisades, based on the Standard Technical Specifieation

, model and in conformance w~th our pos.-ition are enclosed.

In addition, during a recent review of Technical Specffication require-ments for supervision of core alterations we noted that-the Technical-,,

..

  • Specif1cat1ons *for the Palisades Plant do not conform w1th the.current'......

NRC posit1_on.

The NRC position is that all core alterations should be

. d~rectly supervised by either a licensed Senior Reactor Operator* or Senior Reactor Operator Limited to Fuel Handling who has no other "qm-cur~ent responsibilities during this operation.

Your Technical Specifications require that core alterations be performed by a-*

licensed Reactor Opera tor under the g~nera 1 supervision of a Senior Rea*ctor Operator.

Si11ce the _ 1 icensed Reactor Operator ex,amination does 'l'lOt appropriately emphasize core alterations, your cu_rrent Technical Specification_ Section 6~2.2.e does *not assure. the required

. degree of direct control of core alterations.

79*os1 a obct7 REGULATORY DOCl{frEl.lE COPY

\\

OP'P'ICK..

. t. i *. l *t t.* I

~............................. ~..... :................... :*........... :

.......... ~................ :............. :

DATE.

NW: POUi 318 (9*76~ NB.CM, 02"9

  • u.a. GOVllRNMBNT ~RINTINO OP'P'ICa:; t 071
  • ZOii... 1**

Mr*. David Bi xe 1

.-LJ.

2 JUL l*t; 1979 You are requested to r~view -the *enclosed_ suggested specification_ and

. to propose* Technical Spec1f1cat1on changes to bring the. reviews by Palisad~s review committee and the control of core alterations into confonnance with our positions.

We request that you submit your proposed* changes to Technical Specifications within 60 days of the date of this letter.

EnclOsure:

As_ stated cc:

s'ee next page

. Sincerely,._* -.

Original Signed by:.

Denni~*L. Z1~I118Jin Dennis L. Ziemann, Chief

.Operating* Reactors Bran~h #2 Division of Operating Reactors

~::uno~*

~~~

50~.2~

Local PDR ORB#2 RDG NRR. RDG. *

-OEi sen hut

  • sGrimes RVollmer*

TCarter

  • WRussel 1
  • Attorney, OELD.
  • OI&E(3)

DLZiemqnn RSilver

. HSmi th DBri n kman SBryan, *r &E JRBuchanan TERA ACRS(l6)

'/

(

  • ~

. ~h

~~~~~:!~ H~~i*;~~!:~.. ***:.. ::.. -'...:.::. :.......... ***:*:*.......

/

/

: !.!./.:;;/ ?.~:: :~:: ~::.. :~:?iii :d:~:: :: : : : : :.
  • ." :?Y J:if.I. ~ '.:::::::. : : : : : : : : : : : : : : : '.:::::::::.: : : : : : : :: : : :.:::::: :.: : : : : : : : : : : : : : : :.::::::: :::::

OURNAMB.

DATK~

NRC PORM 318 (9*76) NJlCM 0240 1't.. u.s. 'GOVURNMBNT PRINTING OP'P.ICR :-t t7~:. ZOI.. 711

Mr. David Bixel cc M. I. Miller, Esquire Isham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois. 60670 Mr. Paul A. Perry, Secretary Consumers Power Company 212 West Mi~higan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power.Company 212 West Michigan Avenue Jackson, Michigan 49201 Myron M. Cherry, Esquire Suite 4501 One IBM Plaza Chicago, Illinois 60611 Kalamazoo Public Library 315 South Rose Street Kalamazoo, Michigan 49006

  • ..JUL 1 2 1979

L REVIEW COMMITTEE QUORUM REQUIREMENTS PALISADES PLANT

. ENCLOSURE Technical Specifications which conform to the NRC position on review corrmittee actions are stated below:

QUORUM 6.5.1.5 The minimum quorum of the PRC necessary for the performance of the PRC responsibility and authority provisions of these technical specifications shall consist of the Chairman or his designated alternate and four members inc 1 ud i ng alternates.

QUORUM 6.5.2.6 The minimum quorum of the SARB necessary for the performance of.

the SARB review and audit functions of these technical specifications shall consist of the Chairman or his designated alternate and at least 4 SARB members including alternates.

No more than a minority of *the quorum shall have line responsibility for operation of the unit;

  • l...

CORE ALTERATIONS. SUPERVISION PALISADES.PLANT ENCLOSURE Technical Specifications which confonn to the NRC position on supervision of core alterations are stated below:

6 *. 2. 2. e ALL CORE ALTERATIONS shall be directly supervised by either a licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling who has no other concurrent responsibilities during this operation.

Table 6.2-1 Footnote

  • Does not include the licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling, supervising CORE ALTERATIONS.