ML18043A928

From kanterella
Jump to navigation Jump to search
Forwards Revision 3 to Plant Steam Generator Repair Rept, in Response to 790516 Request for Addl Info
ML18043A928
Person / Time
Site: Palisades Entergy icon.png
Issue date: 08/03/1979
From: Bixel D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Ziemann D
Office of Nuclear Reactor Regulation
Shared Package
ML18043A930 List:
References
NUDOCS 7908090350
Download: ML18043A928 (1)


Text

J..

e consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Michigan 4g201

  • Area Code 517 788-0550 August 3, 1979 Director, Nuclear Reactor Regulation Att Mr_ Dennis L Ziemann, Chief Operating Reactors Branch No 2 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET. 50-255 - LICJ?NSE DPR PALISADES PLANT -

STEAM GENERATOR REPAIR REPORT - REVISION 3 JULY 1979 Attached is Revision 3 dated July 1979 of the "Palisades Plant Steam Generator Repair Report.", This Revisionp contains responses to requests for additional information transmitted by letter dated May 16, 1979.

David.A Bixel (Signed)

David', A Bixel Nuclear Licensing Administrator cc JGKeppler, USNRC

'l 90809 0 350 ~