Text
I **
UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION 111
799 ROOSEVELT ROAD
GLEN ELLYN, ILLINOIS 60137
Docket No. 50-255
Consumers Power Company
ATTN:
Mr. R. B. DeWitt
Manager of Nuclear
Plant Operations
212 West Michigan Avenue
Jackson, MI
49201
Gentlemen:
DEG 1 ~.
,.,8
-.:; I
This refers to the inspection conducted by Messrs. B. L. Jorgensen
and D. R. Hunter of this office on November 14-17, 1978, of activi-
ties at Palisades Plant authorized by NRC Operating License No.
DPR-20 and to the discussion of our findings with Mr. Keiser and
others at the conclusion of the inspection *
The enclosed copy of our inspection report identifies areas
examined during the inspection.
Within these areas, the
inspection consisted of a selective examination of procedures
and representative records, observations, and interviews with
personnel.
No items of noncompliance with NRC requirements were identified
during the course of this inspection.
In accordance with Section 2. 790 of the NRC's "Rules of
Practice," Part 2, Title 10, Code of Federal Regulations, a
copy of this letter and the enclosed inspection report will
be placed in the NRC's Public Document Room, except *as follows.
If this report contains information that you or your contractors
believe to be proprietary, you must apply in writing to this
office, within twenty days of your receipt of this letter, to
withhold such information from public disclosure.
The
application must include a full statement of the reasons for
which the information is considered proprietary, and should be
prepared so that proprieta-ry information identified in the
application is contained in an enclosure to the application .
790.tt.86 "'353
Consumers Power Company
-
2 -
DEC l"f.
We will gladly discuss any questions you have concerning this
inspection.
Sincerely,
Gaston Fiorelli, Chief
Reactor Operations and
Nuclear Support Branch
Enclosure:
IE Inspection
Rpt No. 50-255/78-27
cc w/encl:
Mr. J. G. Lewis. Plant
Superintendent
Central Files
Reproduction Unit NRC 20b
Local PDR
Ronald Callen, Michigan Public
Service Commission
Myron M. Cherry, Chicago
RIII
RIII
RIII
OFFICE .. ._ ___ t<Jf-.Ov------ '----'{\\\\~-----
it~------
SU RNAME!il>
.J.QIR~D.?_~uL<ies: _lIJJ_nt~_L _______ Riarnick _____ _
DAT~ 12/11/78
.
--- --- ---- -------- f------ ------ -- ---
RIII
~~~~:::::: ::::::::-:::::::
NRC Form 3186 (Rm) (l-78) NRCM 0240
- U. S, GOVERNMENT PRINTING OFFICE: 1978-253"'817