Rev 1 to 50147-C-012, HCLPF Calculations for Selected Blockwalls.
ML18039A627
Person / Time
Site: Browns Ferry 
Issue date: 11/10/1998
From: Dizon J
EQE ENGINEERING CONSULTANTS (FORMERLY EQE ENGINEERING
To:
References
REF-GTECI-A-46, REF-GTECI-SC, TASK-A-46, TASK-OR
Download: ML18039A627 (30)
Rev 1 to 50147-C-011, HCLPF Calculations for Electrical Equipment on A-46 Safe Shutdown Equipment List.
ML18039A626
Person / Time
Site: Browns Ferry 
Issue date: 07/15/1996
From: Dizon J
EQE ENGINEERING CONSULTANTS (FORMERLY EQE ENGINEERING
To:
References
REF-GTECI-A-46, REF-GTECI-SC, TASK-A-46, TASK-OR
Download: ML18039A626 (177)
Rev 1 to CD-Q0000-940339, Calculation of Basic Parameters for A46 & IPEEE Seismic Program.
ML18039A625
Person / Time
Site: Browns Ferry 
Issue date: 10/16/1995
From: Beason J, Ghosal P, Glass J
TENNESSEE VALLEY AUTHORITY
To:
References
REF-GTECI-A-46, REF-GTECI-SC, TASK-A-46, TASK-OR
Download: ML18039A625 (87)
Forwards Partial Response to NRC 980916 RAI Re BFN Ipeee. Response Discusses Seismic,Fire,Flooding & Transportation & Nearby Facility Accidents.Revised Relevant Calculation, Encl
ML18039A619
Person / Time
Site: Browns Ferry 
Issue date: 11/25/1998
From: Abney T
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
REF-GTECI-A-46, REF-GTECI-SC, TASK-A-46, TASK-OR
Download: ML18039A619 (98)