ACCESSION=NBR:9607290220 DOC.DATE: 96/07/22 NOTARIZED: NO DOCKET I FACIL:50-'260 Browns Ferry Nuclear Power Station, Unit 2, Tennessee 05000260 AUTH.NAME AUTHOR AFFILIATION SALAS,P.,

Tennessee Valley Authority RECIP.NAME RECIPIENT AFFILIATION Document 'Control Branch (Document Control Desk)

SUBJECT:

Forwards "BFN Unit 2 Cycle 8 ISI NIS-1 Rept."

DISTRIBUTION CODE:

A047D COPIES RECEIVED:LTR 1

ENCL 1

SIZE:

TITLE: OR Submittal:.Inservice/Testing/Relic(

from ASME Code GL-89-04 NOTES:

RECIPIENT ID CODE/NAME PD2-3 WILLIAMS,J.

INTERNAL: ACR E CEN E

NRR

. DE/EMCB NUDOCS-ABSTRACT RES/DET/EMMEB EXTERNAL: LITCO ANDERSON NRC PDR COPIES LTTR ENCL 1

1 1

1 6

0 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD2-3-PD AEOD/SPD/RAB NRR/DE/ECGB NRR/DE/EMEB OGC/HDS3 RES/DSIR/EIB NOAC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 0

1 1

1 1

D U

E NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!

CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN 5D-5(EXT. 415-2083)

TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF'OPIES REQUIRED:

LTTR 21 ENCL 14

lQI

~

'.1 II~

Tennessee Valley Authority. Post Office Box 2000. Oecatur. Alabama 35609 JUL 32 1996 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C.

20555 Gentlemen:

In the Matter of Tennessee Valley Authority Docket No. 50-260 BROWNS FERRY NUCLEAR PLANT (BFN)

UNIT 2 CYCLE 8 INSERV1CE INSPECTIONS AND REPAIR AND REPLACEMENTS

SUMMARY

REPORTS In accordance with paragraphs IWA-6220 and IWA-6230 of the American Society of Mechanical Engineers Boiler and Pressure Vessel

Code,Section XI, 1986 Edition, TVA is submitting the BFN Unit 2 summary reports for NRC review.

The summary reports are for inservice inspection, and repair and replacement activities for Unit 2 Cycle 8 from November 24,

1994, through April 24, 1996.

Additionally, TVA is including an update to the Unit 2 Cycle 6 inservice inspection report and corrections to the Unit 2 Cycle 6 repair and replacement report.

These reports were initially transmitted to NRC by TVA letter dated August 27, 1993.

Enclosure 1 contains BFN's Unit 2 inservice inspection summary reports for Code Class 1 and 2 pressure retaining components and their 'supports.

Enclosure 2 contains repair and replacement reports for Code Class 1 and 2 components and supports.

Additionally, Enclosure 3 provides an update to BFN's Unit 2 'Cycle 6 inservice inspection report.

Enclosure 4

provides a correction to NIS-2 Forms for two workplans submitted in the Unit 2 Cycle 6 repair and replacement data report.

9 OQQ71 ttf607290220 960722 PDR DR ADQCK 050002 PDR 8

Ck

~li

U.S. Nuclear Regulatory Commission Page 2

JUL P,2 1996 There are no commitments contained in this letter. If you have any questions regarding these reports, please contact me at '(205) 729-2636.

Si el ro Sa'las Manager.of 'Site Licensing Enclosures cc:

See page 2

'li J

U.S:. Nuclear Regulatory Commission Page 3

JUL 22 1996 Enclosures cc (Enclosures):

Mr. 'Mark S:." Lesser, Branch Chief U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta,, Georgia 30323 NRC Resident Inspector Browns Ferry Nuclear Plant 10833 Shaw Road

Athens, Alabama 35611 Mr. J.

F. Williams, Project Manager U.S. Nucl'ear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852

I~

~P 7

ENCLOSURE 1

TENNESSEE'ALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNIT 2 INSERVICE INSPECTIONS AND AUGMENTED EXAMINATIONS

SUMMARY

REPORT FOR CYCLE 8 OPERATION (SEE ATTACHED)

4l 0

11 I