Notice of Violation from Insp on 890515-0615.Violation Noted:From 890510-25,only RHR Loop I Pump a Operable & RHR Loop II Pumps B & D Inoperable for Scheduled Outage.Caused by Pump Area Cooler Fan Motor Rotation Reversed
ML18033A884
Person / Time
Site: Browns Ferry  
Issue date: 08/04/1989
From: Wilson B
Office of Nuclear Reactor Regulation
To:
Shared Package
ML18033A883 List:
References
50-260-89-20, NUDOCS 8908180174
Download: ML18033A884 (3)


Text

ENCLOSURE 1 NOTICE OF VIOLATION Tennessee Valley Authority Browns Ferry 2

Docket No. 50-260 License No.

DPR-52 During the Nuclear Regulatory Commission (NRC) inspection conducted May 15-June 15,

1989, a violation of NRC requirements was identified.

The violation involved failure to comply with Technical Specification requirements to maintain a

minimum number of Residual Heat Removal (RHR) pumps operable.

In accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C (1985), the violation is listed below:

A.

Technical Specification (TS) 3.5.B.9 requires that at least one RHR loop with two pumps or two loops with one pump per loop be operable when the reactor vessel pressure is atmospheric and irradiated fuel is in the reactor vessel.

TS 3.5.D. 1 requires that the equipment area cooler associated with each RHR pump be operable at all times when the pump served by that specific cooler is considered to be operable.

TS 3.5.-D.2 states that when an equipment area cooler is not operable, the pump served by that cooler must be considered inoperable for TS purposes.

Contrary to the

above, during the period of May 10-25, 1989, the licensee did not meet the TS requirements for at least two operable RHR pumps.

During this period, only RHR Loop I pump "A" was operable, the RHR Loop II pumps ("B" and "D") were inoperable for a scheduled

outage, and RHR Loop I pump "C" was inoperable due to its associated pump area cooler fan motor rotation being reversed.

II This is a Severity Level IV Violation (Supplement I) and is applicable to Unit 2.

Pursuant to the provisions of 10 CFR 2.201, you are hereby required to submit a

written statement. or explanation to the Nuclear Regulatory Commission, ATTN:

Document Control

Desk, Mashington, DC 20555, with a copy to the Associate Director for Special
Projects, Office of Nuclear Reactor Regulation, and a

copy to the NRC Resident Inspector, Browns Ferry, within 30 days of the date of the letter transmitting this Notice.

This reply should be clearly marked as a "Reply to a Notice of Violation" and should include:

(1) admission or denial of the violation, (2) the reason for the violation if admitted, (3) the corrective steps which have been taken and the results

achieved, 8908i80i74 890804 PDR ADOCK 05000259 6

1 m

1

Tennessee Valley Authority Docket No. 50-260 License No.

DPR-52 (4) the corrective steps which will be taken to avoid further violations, and (5) the date when full compliance will be achieved.

Where good cause is shown, consideration wi 11 be given to extending the response time.

FOR THE NUCLEAR REGULATORY COMMISSION Bruce Wilson, Assistant Director

~

~

~

~

for. Inspection Programs TVA Projects Division Office of Nuclear Reactor Regulation Dated at Atlanta, Georgia this 4th day of Aug.

1989