ML18033A415

From kanterella
Jump to navigation Jump to search
Application for Amends to Licenses DPR-33,DRP-52 & DPR-68, Amending Tables 3.2.A & 3.2.B to Allow Specific Reactor Low Level Instruments to Be Out of Svc When Reactor Vessel Water Level Monitoring Sys Mod Being Performed.Fee Paid
ML18033A415
Person / Time
Site: Browns Ferry  
Issue date: 10/17/1988
From: May M
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML18033A416 List:
References
GL-84-23, NUDOCS 8810260225
Download: ML18033A415 (6)


Text

REGULAt P

INFORMATION DISTRIBUTIQl YSTEM (RIDS)

ACCESSION NBR: 8810260225 DQC. DATE: 88/10/17 NOTARIZED:

YES DOCKET 8 FACIL: 50-259 Browns Ferry Nuclear Power Stations Unit 1I Tennessee 05000259 50-260 Browns Ferry Nuclear Power Stationi Unit 2i Tennessee 05000260 50-296 Browns Ferry Nuclear Power Stat ioni Unit 3I Tennessee 0500029'6 AUTH. NAME AUTHOR AFFILIATION MAYiM. J.

Tennessee Valley Authority RECIP. NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Application for amends (TS-260) to Licenses DPR-33'RP-52 Zc

~

DPR-68 re core spray sos.

DISTRIBUTION CODE:

DOSOD COPIES RECEIVED: LTR Q ENCL i

SIZE:.~ +/7 i TITLE:

TVA Facilities Routine Correspondence NOTES: 1 B.

B.

1 B ~

Copy each to:

F. McCog. J. G. Partlowi S. Richardson> S. Blacks D. Liaw.

Copy each to:

S. Blacks J. G. Partlowi S. Richardson D. Liawi F. McCog.

Copy each to:

S.

Blacks J. G. Partlowa S. Richardson D. Liaw> F. McCog.

, 05000259 05000260 0500025'6 RECIPIENT ID CODE/NAME SIMMSI M GEARS' INTERNAL: ACRS OCS ABSTRACT 01 EXTERNAL:

LPDR NSIC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD ADM/LFMB OGC/HDS2 NRC PDR COPIES LTTR ENCL 1'

1 0

1 0

1 1

NOTES:

5

>G4&< g Z'&

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 16 ENCL 14

II

~P

]

IP e

I PP l,"

P 4

g g

f L

TVA-BFN-TS-260 TVA-BFN-TS-261-T 0

~

TENNESSEE VALLEYAUTHORITY CHATTANOOGA. TENNESSEE 37401 5N 157B Lookout Place QIT.i7 1988 U.

S.

Nuclear Regulatory Commission ATTN:

Document Control Desk Nashington, D.C.

Gentlemen:

In the matter of Tennessee Valley Authority Docket Nos.

50-259 50-260 50-296 BRONNS FERRY NUCLEAR PLANT (BFN) UNITS 1, 2, AND 3 TVA TECHNICAL SPECIFICATION (TS)

NO. 260-CORE SPRAY SYSTEM <3.5.A.5)

AND UNIT 2 TECHNICAL SPECIFICATION NO. 261-T TABLES 3.2.A AND 3.2.B This letter supercedes our letter dated October 14, 1988 in which TVA inadvertently omitted the

$ 150 amendment fee as required by 10 CFR 170.12 and failed to include a signature under "oath or affirmation" as required by 10 CFR 50.30(b).

Please replace the October 14, 1988 letter with this letter.

TVA regrets any inconvenience this omission may have caused.

In accordance with the provisions of 10CFR50.4 and 50.90, we are submitting a

request for amendment (TS-260) to licenses DPR-33, DPR-52, and DPR-68 to change the BFN TS for units 1, 2, and 3 and temporarily amend unit 2 TS (TS-261-T) license DPR-52 (enclosure 1).

NRC Generic Letter 84-23, dated October 26, 1984 discussed some problems NRC identified pertaining to the Reactor Vessel Level Monitoring System which was installed in many BNR plants.

In evaluating this concern, TVA subsequently committed to move the reactor vessel water level reference column outside the drywell prior to BFN unit 2 restart.

In recent discussions with NRC, it was agreed that the subject modification be completed prior to BFN unit 2 fuel load.

In order to support this schedule, TVA is requesting your approval of the enclosed proposed Technical Specifications.

Proposed TS 260 amends the Limiting Condition f'r Operation (LCO) section 3.5.A.5 which requires specific conditions to be met when various work, involving the reactor vessel, is being performed.

Proposed TS 261-T temporarily amends the unit 2 Tables 3.2.A and 3.2.B to allow specific reactor low water level instruments to be out-of-service during that time the Reactor Vessel Hater Level Monitoring System modification is being performed.

PDR 22~ 88i0i7 88i 02 R

ADOCK 05000259 PDC

~

An Equal Opportunity Employer g0)

< lpg

)cent V

]y$2

U.S.

Nuclear Regulatory Commission OIT.i.'I 188 Reason for change, description and justification in support of the proposed changes are enclosed (enclosure 2).

A proposed determination of no significant hazards consideration is provided in enclosure 3.

Enclosed is a check for the

$ 150 amendment fee required by 10CFR170.12.

If you have any questions please contact Mr. P.

P. Carier at (205) 729-3566.

Very truly yours, TE SEE VALLEY RITY Michael J.

May, Act M

Technical Services Subscribed tid sworn to before me on is, 'ay of 1988.

C otal Publicp My Commission Expires Enclosures cc:

See page 3

~

ill E

'a 1

~

k,r'$

4h~

0

~'>

f y CP

/

~

~

V

U.S.

Nuclear Regulatory Commission cc (Enclosures):

Ms.

S.

C. Black, Assistant Director for Projects TVA Projects Division U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 Mr. Charles RE Christopher

Chairman, Limestone County Commission P.O.

Box 188

Athens, Alabama 35611 Dr. C.

E.

Fox State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36104 Mr. J.

E. Jones General Electric Company No.

1 Union Square 808 Krystal Building Chattanooga, Tennessee 37402 Mr. F.

R.

McCoy, Assistant Director for Inspection Programs TVA Projects Division U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Browns Ferry Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637

Athens, Alabama 35611 American Nuclear Insurers Attention:

Librarian The Exchange,: Suite 245 270'armington Avenue Farmington, Connecticut 06032