OFFICIAL USE ONLY - PROPRIETARY INFORMATION February 1, 2018 Mr. Wren Fowler Licensing Manager NAC International 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092
SUBJECT:
APPLICATION FOR AMENDMENT NO. 8 TO THE MODEL NO. MAGNASTOR STORAGE CASK - REQUEST FOR ADDITIONAL INFORMATION
Dear Mr. Fowler:
By letter dated June 23, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17179A382), as supplemented on July 5, 2017 (ADAMS Accession NO. ML17206A077), NAC International (NAC) submitted an application in accordance with Title 10 of the Code of Federal Regulations Part 72 to amend Certificate of Compliance No. 1031 for the Model No. MAGNASTOR storage system to add a new damaged fuel basket and a shorter version of the canister, transfer cask, and storage cask.
In connection with our review, we need the information identified in the enclosure to this letter.
Additional information requested by this letter should be submitted in the form of revised safety analysis report pages. Please provide your response within 2 months from the date of this letter.
Please reference Docket No. 72-1031 and Enterprise Project Identifier (EPID) No.
L-2017-LRM-0009 in future correspondence related to this request. The staff is available to meet to discuss your proposed responses. If you have any questions, I may be contacted at (301) 415-6577.
Sincerely,
/RA/
Bernard H. White IV, Senior Project Manager Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-1031 EPID No. L-2017-LRM-0009
Enclosure:
Request for Additional Information OFFICIAL USE ONLY - PROPRIETARY INFORMATION Upon removal of Enclosure 2, this document is uncontrolled
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION APPLICATION FOR AMENDMENT NO. 8 TO THE MODEL NO. MAGNASTOR STORAGE CASK - REQUEST FOR ADDITIONAL INFORMATION, DATE: FEBRUARY 1, 2018 Electronic Distribution: S. Everard, G:\\SFST\\Bernie White\\Casework\\NAC\\MAGNASTOR\\Amd 8\\RAI 1.docx ADAMS Package Accession No.: ML18032A439 Letter ADAMS Accession No.: ML18032A440 ADAMS Accession No.: ML18032A441 ADAMS Accession No.: ML18032A442 OFC DSFM DSFM DSFM DSFM NAME BWhite WWheatley via email JBorowsky via emai EGoldfeiz via email DATE 1/19/18 1/ 19 /18 1/19/18 1/22/18 OFC DSFM DSFM DSFM NAME ABarto for TTate via email YDiaz-Sanabria via email MRahimi DATE 1/30/18 1/19/18 2/1 /18 OFFICAL RECORD COPY