RKGULATORY INFORMATION DISTRIBUTION Sh KH (RIOS)
ACCESSION NBR:8105220169 DOC ~ OA'TE: 81/05/20 NOTARIZE5:
NO DOCKET ¹ FACIL:50 387 Susquehanna Steam Electric Stationr Unit 1P Pennsylva 5%1938 50 388 Susquehanna Steam Electric Station~
Unit 2> Pennsylva 05000388 AUTH SNARE AUTHOR AFFILIATION CURT?SENT
're
-Pennsylvania Power Z. Light Co, REC IP. VA lE RECIPIENT AFFILIATION VOUNGBLOOOrB.J, Licensing Branch 1
SUBJECT; Commits to installation fo automatic r'eset mod detection logic prior. to fuel loading continE3ent delivery ot aualified equioyent
~ Mods address SER Issues 91 8
92 respectively'ISTR ISUTIO"I CODE:
BOO IS COPIES RECEIVED:LTR
~RCL TITLE: PSAR/FSAR AHOTS and Related Correspondence oreak uDon Outstanding SIZE:
NOTES:Send l8E 3 cooies FSAR 8 all amends.i cy:BAR LRG PR(L.RIB)
Send IRK 3 copies FSAR L al l amends
~ 1 cy.'BWR-LRG Pv(L ~ RIB) 05000387 0S000388 RKC IP IEhj T CODE/NATE ACTION:
A/0 LICENSNG RUSHBROOK0M ~
INTERNAL'CCID EVAL BR26 CHK'4 KNG BR Od CORE PELF BR 10 K<ERG PREP 22 GEOSCIEVCES 1Q AYD/GEO BR 15 ILK 06 LIC QUAL RR MECH EVG SR 18 NRC POR 02 OP LIC BR PROC/TST REV 20 S
BR22 REG FI 01 CT ENG BR25 COPIES LTTR ENCL 1
1 RECIPIENT ID COOK/NAhtE LIC BR ¹2 BC STARKr R ~ '~
AUX SYS BR 07 CONT SYS BR 09 EFF TR SYS BR1P EQUIP QUAL BR13
'lUM FACT KNG BR lKC SYS BR 16 LIC GUIO 9R NATL ENG BR 17
~PA OELD
>OWER SYS BR 19 QA BR 21 REAC SYS BR 23 SIT ANAL BR 2~
COPIES LTTR ENC 1
EXTERNAL:
1 LPOR 0'3
~7 TOTAL NURSER OF CO IES REQUIRED:
LTT~ ~ ENCL
TWO 'NORTH NINTH STREET, ALLENTOWN. PA.
18101 PHONE: (215) 821-5151 IIQRMANVA CURTIS Vice President-En~neefing a Constfcc'tion 82l-538 t May 20, 1981 Mr. B.J.
Youngblood, Chief Licensing Branch No.
1 U.S. Nuclear Regulatory Commission Washington, D.C.
20555
~ Docket Nos 50-387 50-388 Susquehanna Steam Electric Station RCIC System - Automatic Reset Modification (SER Outstanding Issue 91)
HPCI and RCIC System - Break Detection Logic (SER Outstanding Issue 92)
ER100450 File 841-2
Dear Mr. Youngblood:
PP&L commits to install both of the subject modifications prior to fuel loading contingent upon delivery of qualified equipment.
These modifications are those developed by General Electric and accepted by the BWR Owners Group.
( 12/29/80 - letter from D.B. Waters to D. Eisenhut)
Very truly yours, N.W. Curtis Vice President-Engineering 5 Construction-Nuclear CTM/mks Attachment cc:
R.M. Stark
/~n fi