REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:8106120217 OOC ~ DATE: 81/06/10 'OTARIZED:
NO DOCKET ¹ FACII.:50 387 Susquehanna Steam 'Electric Stations Unit 1>.Pennsyiva 05000387 50 388 Susquehanna Steam Electric Stationr Unit 2E Pennsylva 05 AUTH BYNAME AUTHOR'FFILIATION'URTIS p N ~ Ii ~
Pennsylvania Power 8 Light Co ~
RKCIP ~ NAME RECIPIENT AFFILIATION SCHWENCERPA ~
Licensing Branch 2
SUBJECT:
Advises that sympton based emergency procedures have been constructed to caution operator against diversion of I.PCI flow to wetwell spray unless adeauate core cooling is assured>resolving SER.Outstanding Issue 37.
DISTRIBUTION CODE:
SOOIS COPIES RECEIVED:LTR J ENCL SIZE:
TITLE: PSAR/FSAR AMDTS and Related Corresoondence NOTES:Send I8E 3 copies FSAR 8 all amends F 1 cytB'AR LRG PM(L RIB)
Send I8,E 3 copies FSAR 8 all
- amends, 1
cy:BNR LRG PM(CRIB) 05000387 05000388 RECIPIENT ID COOK/NAME ACTION:
A/D LICENSNG LIC BR ¹2 LA lNTERNAI: ACCID EVAL BR26 CHEM ENG BR 11 CORE PERF BR 10 EMKRG PREP 22 EMRG PRP LIC 36 FE'IA REP DIV 39 HU"I FACT ENG 40 I'LC SYS BR 16 LI C GU ID
'3R 33 MATL ENG BR 17 MPA OELD PORER SYS BR 19 QA BR 21 REAC SYS BR 23 SIT ANAL BR 24 COPIES LTTR EN L
1 1
REC IP IENT ID CODE/NAME LIC BR ¹2 BC STARK'
~
04 AUX SYS BR 27 CONT SYS BR 09 EFF TR SYS BR12 EMRG PRP DKV 35 EQUIP QUAL BR13 GEOSC IENCES 28 HYD/GEO RR 30 I 8 E" 06 LIC QUAL BR 32 MECH ENG BR 18 NRC'DR 02 OP LIC BR, 34 PROC/TST REV 20 RAD ASSESS BR22 01 RUCT ENG BR25 COPIES LTTR ENCI 1
1 1
1 1
1 1
1 3
2 2
3 1
1 1
1 1
1 1
1 EXTERNAL: ACRS NSIC 41 ns 16 1
1 I POR 03
~q Z6 ~%1
$3 TOTAL NU'UIBER OF COPIES REQUIRED:
LTTR
'NCL 6
PPal C
TWO NORTH NINTH STREET., ALLENTOWN, PA. I 8101 PHONEr (215) 770-5151 NORMAN W. CURTIS Vice President-Engineering rL Construction-Nuclear 770-5381 June 10, 1981 Mr. A. Schwencer, Chief Licensing Branch No; 2
Division of Licensing U.S. Nuclear Regulatory Dommission Washington, D.C.
20555 Docket Nos.
50-387 50-388 SUSqUEHANNA STEAM ELECTRIC STATION SER OUTSTANDING ISSUE 111 37 ER 100450 FILE 841-2 PLA-800 SUVZ3.t'8l ur Sr NUCIIAitat0t'LAT03~
3 COMMI88ION
/~
Dear Mr. Schwencer:
To resolve the concern of the NRC staff that premature diversion of the Low Pressure Coolant Injection (LPCI) flow to wetwell spray could adversely affect core cooling, the Susquehanna SES symptom based emergency procedures have been constructed to caution the operator against such diversion unless "adequate core cooling is assured."
These procedures, which were developed with the assistance of the BWR Owners Group and reviewed and accepted by the NRC staff, clearly identify LPCI diversion as secondary to the core cooling requirements except in those instances, outside the plant design envelope, which involve multiple failures and for which maintenance of containment integrity is required to minimize'risk to the environment.
This letter completes our action on SER Outstanding Issue 837.
Very truly yours, N.
W. Curtis Vice President-Engineering and Construction-Nuclear cc."