SUBJECT:
Interim deficiency rept re defective limitorque limit switch rotors.Following engineering evaluationiinso program will be implemented.Defective rotors will be reolaced.
DISTRIBUTION COOK:
B019S COPIES RECEIVED:LTR KNCL SIZE:
O TITLE: Construction Deficiency Report (10CFR50
~ 55E)
NOTES:Send I8K 3 copies FSAR 8 all
- amends, Send I8E 3 copies FSAR 8 all
- amends, 05000387 05000388 REC IP IEVT ID CODE/NA'iIE ACTION:
A/D LICENSiVG 04 RUSHBROOKgM ~
06 INTERNAL: AD/RCI/IE 17 ASLBP/J ~ HARD EDO 8
STAFF 19 HYD/GEO BR 22 LIC QUAL BR 12 NRC POR 02 PRO ST RKV 13 EG Fl 01 STANDRDS DEV 21 COPIES LTTR ENCL 1
RKCIPIKNT ID CODE/NARK YOUNGBLOODtB 05 STARKgR ~
07 AEOD 18 D/DIR HUM FAC15 EQUIP QUAL BR11 I8K 09 MPA 20 OKLD 21 QA BR 14 RUTHERFORDgd ~ IK COPIES LTTR KNCL 1
1 EXTERNAL: ACRS NSIC 16 08 16 1
1 LPDR 03 Qg g 'f4~@
TOTAL iVU!4IBER OF COPIES REQUIRED:
LTTR ~
ENCL
c'~- ~n TWO NORTH NINTH STREPT, ALLENTOWN, PA.
18101 PHONEME (215) 821 SISI September 23, 1980 19406 Mr. Boyce H. Grier Director, Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania SUSQUEFAKNA STEAM ELECTRIC STATION INTERIM REPORT OF A DEFICIENCY ON DEFECTIVE LZMZTORQUE LIMIT SWITCH ROTORS ERs 100450/100508 FILE 840-4 PLA-547
Dear Mr. Grier:
This letter serves to confirm information provided by telephone to NRC Region I representative Mr. R. McGaughy by Mr. A. R. Sabol of PPaL on August 21, 1980.
During that conversation, Mr. McGaughy was advised that the subject condition was under evaluation for reportability under the provisions of 10CFR50.55(e).
The deficiency involves limit switches on Limitorcpxe valve operators that control the valve operator and are used to provide position indication.
During preoperational checkout of the Limitorcpxe valve operators, cracks were found in the limit switch rotor, The rotor is made of a phenolic material and is staked to a metal pinion shaft.
As the valve operates, the limit switch rotor turns, rotating a moving contact which opens or closes a limit switch contact.
The cracks were found in the limit switch rotor where it is staked to the pinion shaft.
The rotor cracks appear to be caused by a misalignment in the holes in the limit switch rotor and the pinion shaft.
Since the limit switches are used for the control of the valve operator and foz indication for valve position, a defective limit switch rotor could result in the failure of a valve to operate and/or provide incorrect indication of the valve position.
In that these types of failures cculd have an'adverse effect on the safe operation of the nuclear power plant, the defect is considered as reportable under the provisions of 10CFR50.55(e)
A letter was sent to Limitorcpe Corporation which identified the problem and recpested them to determine the
- cause, scope and corrective action for the limit switch rotor problem.
Bechtel NCR 6020 and PPK NCR 80-134 have been written to document known rotor defects in the Core Spray and Reactor.Recirculation systems.
Upon engineering evaluation of the data that Limitoraue provides, an inspection program will be developed and implemented for the conduct of field inspections of the limit switch rotors.
All defective rotors will,be replaced.
3o/7
~~10060'/2 PENNSYLVANIA POWER IL LI G H T COMPANY
Mr. Boyce H. Grier
~ 2 Sept. ember 23, 1980 Since the details of this report provide information relevant to the reporting recuiremen-of 10CFR21, this correspondence is considered to also discharge any formal responsibility PPGL may have for reporting in compliance thereto.
We expect to issue a final report in November, 1980.
Very truly yours, N.
W. Curtis Vice P"esident-Engineering G Construction-Nuclear ARS:mcb cc: