NIIIIlM'QR>'IIII'HK IlQPE Docket I'Los.

60 and'

-38S JUN 30:-SO Hr. Norman M. Curtis Vice President - Engineering qI Constructf on Pennsy'1vanfa Power 8I Light Company 2 North Ninth Street Allentown, Pennsylvania 18101

Dear W.. Curtis:

DISTR IBUTION:

NRC PDR

'LPOR Dt&Ret Ff]e LB81 Rdg TERA DEisenhut

'PUl pie BJYoungblood MRushbrook RHVollmer RNattson-OFRoss JPKnTght RLTedesco VNoonan

~

PCheck LRubenstein ASchwencer JMiller RStar I X C.

~

>C You recently received Inspection 5 Enforcement,Bulletin 80-07; dated April 4,

'980, concerning the cracking of the get pump holddown beams at Dresden 3.

Operating BHR's were requested to provide a written response to this bulletin.

BiIR's not yet operating were issued this bulletin for information only.

put Office of Inspection and Enforcement fs currently monitoring the efforts of General Electrfc and various BWR L'fcensees for developing.

a long-term soIu-tion to the crackfng problem.

Qperatfng BWR's are being required to take certain short-term actions such as inservfce inspection to preclude excessive cracking while a long-term solution fs developed.

It is expected that this long-term solution will be applicable to both operating and non-operating BHR's.

112.10 To aid us In our 'Ilcenslng review or Susquehanna, you are requested to provide the foIlowlng Infonnatlon to us:

Describe those actions being taken by you to preclude the occurrence of cracking such as described in IE Bulletin 80-07.

2..

Provide a commitment to adopt whatever long-term solution fs approved.

3. If you. anticipate receiving an pperatfng License before a long-term solution is agreed upon, describe any short-term actions which you will take to prevent or detect excessive cracking.

Provide a ratfonale as to why these actions are sufffcient to justify olant operation until a long-term solution fs found.

Sincerely.

GRIGii'IALSIG'l-"D BY cc:

See next oa e

B. J.

Youngblood, Chief Licensing Branch No.

1 Dfvisfon of Licensing

. tou7I8'eppes I

OFFICE SURNAME DL:Lgatv RStark".km 06/26/80 OL:LBgl Rush%cook 06/

'1/80

~

~ 'V D~~; L7851 BJYoiangb,l ood 06/ ~ /80 NRC FORM 316 (9-76) NRCM 0240

  • V.S. GOVERNMENT PRINTING OFFICE: 1579 259.369

Mr. Norman W. Curtis cc:

Mr. Earle M. Yead Project Engineering Manager Pennsylvania Pomr

& Light Company 2 North Ninth Street Al I entown, Pennsyl vani a 18101 Jay Silberg, Esq.

Shaw, Pittman,. Potts Trowbridge 1800 M St rect, N.

W.

Washington, O. C.

20036 Yir. Wi 1 1 i am E,

Ba rberi ch, Nuclear Licensing Group Supervisor Pennsylvania Power

& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Edward M. Nagel, Esquire General Counsel and Secretary Pennsylvania Power

& Light Ccmpany 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Bryan Snapp, Esq.

Pennsylvania Power

& Light Company 901 Hamilton Street Allentown, Pennsylvania 18 10 1 Robert M, Gallo Resident Inspector P. 0.

Box 52 Shickshinny, Pennsylvania 18655 Susquehanna Environmental Advocates c/o Gerald Schultz, Esq.

500 South River Street Wilkes-Barre, PA 18702 John L. Anderson Oak Ridge National Laboratory Union Carbide Corporation Bldg. 3500, P. 0.

Box X

Oak Ridge,. Tennessee 37830 Mr. Rober t J. Shovlin Project Manager Pennsylvania Pomr and Light Co.

2 North Ninth Street Allentown, Pennsylvania 18 10 1

'I Matias F. Travieso-Diaz, Esq.

Shaw, Pittman, Potts Trowbri dge 1800 M Street, N.

W.

Washington, O.

C.

20036 Or. Judith H. Johnsrud Co-Oirector Environmental Coalition on Nuclear Power 433 Orlando Avenue State College, PA 16801 Mr. Thomas M, Gerusky, Oi rector Bureau of Radiation Protection Oepartment of Environmental Resources Commonwealth of Pe'nnsylvania P. 0.

Box 2063 Ha rrisburg, PA 17 120 Ms. Colleen Marsh Box 538A, ROg4 Mountain Top, PA 18707 Mrs. Irene Lemanowicz, Chairperson The Citizens Against Nuclear Dangers P. 0.

Box 377 ROPl

Berwick, PA 18503